Cargando…

Quantification of (99m)Tc-DPD concentration in the lumbar spine with SPECT/CT

BACKGROUND: Routine single-photon emission computed tomography (SPECT) currently lacks quantitative information on regional activity concentration (ACC) of the injected tracer (e.g. kBq/ml). Furthermore, little is known on the skeletal absolute concentration of (99m)Tc-DPD after intravenous injectio...

Descripción completa

Detalles Bibliográficos
Autores principales: Cachovan, Michal, Vija, Alexander Hans, Hornegger, Joachim, Kuwert, Torsten
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3680030/
https://www.ncbi.nlm.nih.gov/pubmed/23738809
http://dx.doi.org/10.1186/2191-219X-3-45
_version_ 1782273061259575296
author Cachovan, Michal
Vija, Alexander Hans
Hornegger, Joachim
Kuwert, Torsten
author_facet Cachovan, Michal
Vija, Alexander Hans
Hornegger, Joachim
Kuwert, Torsten
author_sort Cachovan, Michal
collection PubMed
description BACKGROUND: Routine single-photon emission computed tomography (SPECT) currently lacks quantitative information on regional activity concentration (ACC) of the injected tracer (e.g. kBq/ml). Furthermore, little is known on the skeletal absolute concentration of (99m)Tc-DPD after intravenous injection in bone scintigraphy. The aim of this study is to determine ACC in the healthy lumbar vertebrae of patients using a recently published quantitative SPECT/computed tomography (CT) protocol. METHODS: Lumbar vertebrae ACC estimates were performed in 50 female patients (mean age 69.88 ± 13.73 years) who had been administered 562.84 ± 102.33 MBq of (99m)Tc-DPD and had undergone SPECT acquisition 4 h after the injection. The SPECT/CT system was calibrated against a well counter. Images were reconstructed with Flash3D. ACC and CT tissue density were measured in volumes of interest drawn over the spongious bone tissue of the three lower lumbar vertebral bodies when these exhibited no focal CT or SPECT pathology. RESULTS: Average ACC measured in the normal spongious bone tissue was 48.15 ± 13.66 kBq/ml (95% confidence interval (CI) 45.81 to 50.50 kBq/ml). This corresponds to a mean standardised uptake value (SUV) of (5.91 ± 1.54) (95% CI (5.64 to 6.17) SUV). SUV correlated significantly with Hounsfield units (HU) (r = 0.678, p < 0.0001). Significant negative correlations were observed between age and HU (r = −0.650, p < 0.0001) and between age and SUV (r = −0.385, p < 0.0001). CONCLUSIONS: The SUVs determined for (99m)Tc-DPD uptake 4 h post injection are in the same range as those reported for [(18)F]fluoride in positron emission tomography. The strong correlation of SUV with bone CT density underlines the physiological significance of this variable. Our data suggest further investigation of the potential value of ACC measurement in the diagnosis of pathological conditions such as osteoporosis or in following up osseous metastases under therapy.
format Online
Article
Text
id pubmed-3680030
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Springer
record_format MEDLINE/PubMed
spelling pubmed-36800302013-06-14 Quantification of (99m)Tc-DPD concentration in the lumbar spine with SPECT/CT Cachovan, Michal Vija, Alexander Hans Hornegger, Joachim Kuwert, Torsten EJNMMI Res Original Research BACKGROUND: Routine single-photon emission computed tomography (SPECT) currently lacks quantitative information on regional activity concentration (ACC) of the injected tracer (e.g. kBq/ml). Furthermore, little is known on the skeletal absolute concentration of (99m)Tc-DPD after intravenous injection in bone scintigraphy. The aim of this study is to determine ACC in the healthy lumbar vertebrae of patients using a recently published quantitative SPECT/computed tomography (CT) protocol. METHODS: Lumbar vertebrae ACC estimates were performed in 50 female patients (mean age 69.88 ± 13.73 years) who had been administered 562.84 ± 102.33 MBq of (99m)Tc-DPD and had undergone SPECT acquisition 4 h after the injection. The SPECT/CT system was calibrated against a well counter. Images were reconstructed with Flash3D. ACC and CT tissue density were measured in volumes of interest drawn over the spongious bone tissue of the three lower lumbar vertebral bodies when these exhibited no focal CT or SPECT pathology. RESULTS: Average ACC measured in the normal spongious bone tissue was 48.15 ± 13.66 kBq/ml (95% confidence interval (CI) 45.81 to 50.50 kBq/ml). This corresponds to a mean standardised uptake value (SUV) of (5.91 ± 1.54) (95% CI (5.64 to 6.17) SUV). SUV correlated significantly with Hounsfield units (HU) (r = 0.678, p < 0.0001). Significant negative correlations were observed between age and HU (r = −0.650, p < 0.0001) and between age and SUV (r = −0.385, p < 0.0001). CONCLUSIONS: The SUVs determined for (99m)Tc-DPD uptake 4 h post injection are in the same range as those reported for [(18)F]fluoride in positron emission tomography. The strong correlation of SUV with bone CT density underlines the physiological significance of this variable. Our data suggest further investigation of the potential value of ACC measurement in the diagnosis of pathological conditions such as osteoporosis or in following up osseous metastases under therapy. Springer 2013-06-05 /pmc/articles/PMC3680030/ /pubmed/23738809 http://dx.doi.org/10.1186/2191-219X-3-45 Text en Copyright ©2013 Cachovan et al.; licensee Springer. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research
Cachovan, Michal
Vija, Alexander Hans
Hornegger, Joachim
Kuwert, Torsten
Quantification of (99m)Tc-DPD concentration in the lumbar spine with SPECT/CT
title Quantification of (99m)Tc-DPD concentration in the lumbar spine with SPECT/CT
title_full Quantification of (99m)Tc-DPD concentration in the lumbar spine with SPECT/CT
title_fullStr Quantification of (99m)Tc-DPD concentration in the lumbar spine with SPECT/CT
title_full_unstemmed Quantification of (99m)Tc-DPD concentration in the lumbar spine with SPECT/CT
title_short Quantification of (99m)Tc-DPD concentration in the lumbar spine with SPECT/CT
title_sort quantification of (99m)tc-dpd concentration in the lumbar spine with spect/ct
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3680030/
https://www.ncbi.nlm.nih.gov/pubmed/23738809
http://dx.doi.org/10.1186/2191-219X-3-45
work_keys_str_mv AT cachovanmichal quantificationof99mtcdpdconcentrationinthelumbarspinewithspectct
AT vijaalexanderhans quantificationof99mtcdpdconcentrationinthelumbarspinewithspectct
AT horneggerjoachim quantificationof99mtcdpdconcentrationinthelumbarspinewithspectct
AT kuwerttorsten quantificationof99mtcdpdconcentrationinthelumbarspinewithspectct