Cargando…

Bench-to-bedside review: An approach to hemodynamic monitoring - Guyton at the bedside

Hemodynamic monitoring is used to identify deviations from hemodynamic goals and to assess responses to therapy. To accomplish these goals one must understand how the circulation is regulated. In this review I begin with an historical review of the work of Arthur Guyton and his conceptual understand...

Descripción completa

Detalles Bibliográficos
Autor principal: Magder, Sheldon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3682240/
https://www.ncbi.nlm.nih.gov/pubmed/23106914
http://dx.doi.org/10.1186/cc11395
_version_ 1782273368896045056
author Magder, Sheldon
author_facet Magder, Sheldon
author_sort Magder, Sheldon
collection PubMed
description Hemodynamic monitoring is used to identify deviations from hemodynamic goals and to assess responses to therapy. To accomplish these goals one must understand how the circulation is regulated. In this review I begin with an historical review of the work of Arthur Guyton and his conceptual understanding of the circulation and then present an approach by which Guyton's concepts can be applied at the bedside. Guyton argued that cardiac output and central venous pressure are determined by the interaction of two functions: cardiac function, which is determined by cardiac performance; and a return function, which is determined by the return of blood to the heart. This means that changes in cardiac output are dependent upon changes of one of these two functions or of both. I start with an approach based on the approximation that blood pressure is determined by the product of cardiac output and systemic vascular resistance and that cardiac output is determined by cardiac function and venous return. A fall in blood pressure with no change in or a rise in cardiac output indicates that a decrease in vascular resistance is the dominant factor. If the fall in blood pressure is due to a fall in cardiac output then the role of a change in the return function and cardiac function can be separated by the patterns of changes in central venous pressure and cardiac output. Measurement of cardiac output is a central component to this approach but until recently it was not easy to obtain and was estimated from surrogates. However, there are now a number of non-invasive devices that can give measures of cardiac output and permit the use of physiological principles to more rapidly appreciate the primary pathophysiology behind hemodynamic abnormalities and to provide directed therapy.
format Online
Article
Text
id pubmed-3682240
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-36822402013-10-29 Bench-to-bedside review: An approach to hemodynamic monitoring - Guyton at the bedside Magder, Sheldon Crit Care Review Hemodynamic monitoring is used to identify deviations from hemodynamic goals and to assess responses to therapy. To accomplish these goals one must understand how the circulation is regulated. In this review I begin with an historical review of the work of Arthur Guyton and his conceptual understanding of the circulation and then present an approach by which Guyton's concepts can be applied at the bedside. Guyton argued that cardiac output and central venous pressure are determined by the interaction of two functions: cardiac function, which is determined by cardiac performance; and a return function, which is determined by the return of blood to the heart. This means that changes in cardiac output are dependent upon changes of one of these two functions or of both. I start with an approach based on the approximation that blood pressure is determined by the product of cardiac output and systemic vascular resistance and that cardiac output is determined by cardiac function and venous return. A fall in blood pressure with no change in or a rise in cardiac output indicates that a decrease in vascular resistance is the dominant factor. If the fall in blood pressure is due to a fall in cardiac output then the role of a change in the return function and cardiac function can be separated by the patterns of changes in central venous pressure and cardiac output. Measurement of cardiac output is a central component to this approach but until recently it was not easy to obtain and was estimated from surrogates. However, there are now a number of non-invasive devices that can give measures of cardiac output and permit the use of physiological principles to more rapidly appreciate the primary pathophysiology behind hemodynamic abnormalities and to provide directed therapy. BioMed Central 2012 2012-10-29 /pmc/articles/PMC3682240/ /pubmed/23106914 http://dx.doi.org/10.1186/cc11395 Text en Copyright ©2012 BioMed Central Ltd
spellingShingle Review
Magder, Sheldon
Bench-to-bedside review: An approach to hemodynamic monitoring - Guyton at the bedside
title Bench-to-bedside review: An approach to hemodynamic monitoring - Guyton at the bedside
title_full Bench-to-bedside review: An approach to hemodynamic monitoring - Guyton at the bedside
title_fullStr Bench-to-bedside review: An approach to hemodynamic monitoring - Guyton at the bedside
title_full_unstemmed Bench-to-bedside review: An approach to hemodynamic monitoring - Guyton at the bedside
title_short Bench-to-bedside review: An approach to hemodynamic monitoring - Guyton at the bedside
title_sort bench-to-bedside review: an approach to hemodynamic monitoring - guyton at the bedside
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3682240/
https://www.ncbi.nlm.nih.gov/pubmed/23106914
http://dx.doi.org/10.1186/cc11395
work_keys_str_mv AT magdersheldon benchtobedsidereviewanapproachtohemodynamicmonitoringguytonatthebedside