Optimal glycemic control in neurocritical care patients

Currently, the major issue in glycemic control in neurocritical care patients is that tight glycemic control (target range of 80 to 110 mg/dL) using intensive insulin therapy is associated with higher rates of hypoglycemia without an improvement in survival rate. The review by Kramer and colleagues...

Descripción completa

Detalles Bibliográficos
Autores principales: Bilotta, Federico, Rosa, Giovanni
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3682264/
https://www.ncbi.nlm.nih.gov/pubmed/23106972
http://dx.doi.org/10.1186/cc11521
Descripción
Sumario:Currently, the major issue in glycemic control in neurocritical care patients is that tight glycemic control (target range of 80 to 110 mg/dL) using intensive insulin therapy is associated with higher rates of hypoglycemia without an improvement in survival rate. The review by Kramer and colleagues in this issue of Critical Care confirms these data but provides solid evidence about the relationship between hyperglycemia and worsened neurological outcome after acute brain injury. In accordance with the conclusions of Kramer and colleagues, we recommend that a glucose control goal in neurocritical care patients be in the 'moderate' target range (110 to 180 mg/dL). In addition, we recommend adequate nutrition before and during insulin infusion, avoidance of insulin as a bolus, and the use of continuous insulin infusion, beginning with low doses with titration to individual sensitivity. Careful and accurate glycemic monitoring is especially important when insulin is infused.