Cargando…

FS200 femtosecond laser LASIK flap digital analysis parameter evaluation: comparing two different types of patient interface applanation cones

PURPOSE: To evaluate the safety and efficacy of a novel LASIK flap patient interface (PI) cone with our reported digital analysis and compare for potential differences with the standard metal and glass PI in flap parameters when used with the Alcon/WaveLight FS200 femtosecond laser. PATIENTS AND MET...

Descripción completa

Detalles Bibliográficos
Autores principales: Kanellopoulos, A John, Asimellis, George
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3685444/
https://www.ncbi.nlm.nih.gov/pubmed/23807830
http://dx.doi.org/10.2147/OPTH.S43396
_version_ 1782273690836140032
author Kanellopoulos, A John
Asimellis, George
author_facet Kanellopoulos, A John
Asimellis, George
author_sort Kanellopoulos, A John
collection PubMed
description PURPOSE: To evaluate the safety and efficacy of a novel LASIK flap patient interface (PI) cone with our reported digital analysis and compare for potential differences with the standard metal and glass PI in flap parameters when used with the Alcon/WaveLight FS200 femtosecond laser. PATIENTS AND METHODS: Thirty-six consecutive LASIK patients (72 eyes) subjected to a bilateral femtosecond assisted LASIK procedure with the novel clear cone PI FS200 1505 were examined for flap diameter and flap thickness over the entire flap area via digital analysis performed on intraoperation image (flap diameter) and anterior-segment optical coherence tomography image (flap thickness). This group was compared with an age- and procedure-matched group B from our practice, in which the standard metal and glass PI was employed. RESULTS: Horizontal flap diameter for group A (clear cone) was 7.87 mm ± 0.02 mm (range 7.89–7.84 mm) for 8.00 mm programmed, whereas for group B (metal and glass cone) was 7.85 mm ± 0.04 mm (range 7.93–7.80 mm). Likewise, along the vertical line, flap diameter for group A was 7.84 mm ± 0.02 mm (range 7.85–7.80 mm) and for group B was 7.83 mm ± 0.03 mm (range 7.87–7.80 mm). Central flap thickness for group A was 113.29 μm (±1.19 μm) for 110 μm planned, 122.1 μm (±2.10 μm) for 120 μm planned, and 133.50 μm (±0.71 μm) for 130 μm planned. Group B central flap thickness was, accordingly, 112.8 μm (±1.25 μm), 122.4 μm (±2.15 μm), and 132.50 μm (±0.90 μm). The data evaluated (paired group comparisons) between group A and group B did not show statistically significant differences. CONCLUSION: This study indicates that two PIs in use with the FS200 femtosecond laser are safe and have highly reproducible and accurate flap parameter results, such as achieved diameter and flap thickness. The paired group comparisons between the two PIs’ respective data do not show statistically significant differences.
format Online
Article
Text
id pubmed-3685444
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-36854442013-06-27 FS200 femtosecond laser LASIK flap digital analysis parameter evaluation: comparing two different types of patient interface applanation cones Kanellopoulos, A John Asimellis, George Clin Ophthalmol Original Research PURPOSE: To evaluate the safety and efficacy of a novel LASIK flap patient interface (PI) cone with our reported digital analysis and compare for potential differences with the standard metal and glass PI in flap parameters when used with the Alcon/WaveLight FS200 femtosecond laser. PATIENTS AND METHODS: Thirty-six consecutive LASIK patients (72 eyes) subjected to a bilateral femtosecond assisted LASIK procedure with the novel clear cone PI FS200 1505 were examined for flap diameter and flap thickness over the entire flap area via digital analysis performed on intraoperation image (flap diameter) and anterior-segment optical coherence tomography image (flap thickness). This group was compared with an age- and procedure-matched group B from our practice, in which the standard metal and glass PI was employed. RESULTS: Horizontal flap diameter for group A (clear cone) was 7.87 mm ± 0.02 mm (range 7.89–7.84 mm) for 8.00 mm programmed, whereas for group B (metal and glass cone) was 7.85 mm ± 0.04 mm (range 7.93–7.80 mm). Likewise, along the vertical line, flap diameter for group A was 7.84 mm ± 0.02 mm (range 7.85–7.80 mm) and for group B was 7.83 mm ± 0.03 mm (range 7.87–7.80 mm). Central flap thickness for group A was 113.29 μm (±1.19 μm) for 110 μm planned, 122.1 μm (±2.10 μm) for 120 μm planned, and 133.50 μm (±0.71 μm) for 130 μm planned. Group B central flap thickness was, accordingly, 112.8 μm (±1.25 μm), 122.4 μm (±2.15 μm), and 132.50 μm (±0.90 μm). The data evaluated (paired group comparisons) between group A and group B did not show statistically significant differences. CONCLUSION: This study indicates that two PIs in use with the FS200 femtosecond laser are safe and have highly reproducible and accurate flap parameter results, such as achieved diameter and flap thickness. The paired group comparisons between the two PIs’ respective data do not show statistically significant differences. Dove Medical Press 2013 2013-06-10 /pmc/articles/PMC3685444/ /pubmed/23807830 http://dx.doi.org/10.2147/OPTH.S43396 Text en © 2013 Kanellopoulos and Asimellis, publisher and licensee Dove Medical Press Ltd. This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited.
spellingShingle Original Research
Kanellopoulos, A John
Asimellis, George
FS200 femtosecond laser LASIK flap digital analysis parameter evaluation: comparing two different types of patient interface applanation cones
title FS200 femtosecond laser LASIK flap digital analysis parameter evaluation: comparing two different types of patient interface applanation cones
title_full FS200 femtosecond laser LASIK flap digital analysis parameter evaluation: comparing two different types of patient interface applanation cones
title_fullStr FS200 femtosecond laser LASIK flap digital analysis parameter evaluation: comparing two different types of patient interface applanation cones
title_full_unstemmed FS200 femtosecond laser LASIK flap digital analysis parameter evaluation: comparing two different types of patient interface applanation cones
title_short FS200 femtosecond laser LASIK flap digital analysis parameter evaluation: comparing two different types of patient interface applanation cones
title_sort fs200 femtosecond laser lasik flap digital analysis parameter evaluation: comparing two different types of patient interface applanation cones
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3685444/
https://www.ncbi.nlm.nih.gov/pubmed/23807830
http://dx.doi.org/10.2147/OPTH.S43396
work_keys_str_mv AT kanellopoulosajohn fs200femtosecondlaserlasikflapdigitalanalysisparameterevaluationcomparingtwodifferenttypesofpatientinterfaceapplanationcones
AT asimellisgeorge fs200femtosecondlaserlasikflapdigitalanalysisparameterevaluationcomparingtwodifferenttypesofpatientinterfaceapplanationcones