Cargando…

Maximum yields of microsomal-type membranes from small amounts of plant material without requiring ultracentrifugation

Isolation of a microsomal membrane fraction is a common procedure in studies involving membrane proteins. By conventional definition, microsomal membranes are collected by centrifugation of a postmitochondrial fraction at 100,000g in an ultracentrifuge, a method originally developed for large amount...

Descripción completa

Detalles Bibliográficos
Autores principales: Abas, Lindy, Luschnig, Christian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Academic Press 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3685806/
https://www.ncbi.nlm.nih.gov/pubmed/20193653
http://dx.doi.org/10.1016/j.ab.2010.02.030
_version_ 1782273741914374144
author Abas, Lindy
Luschnig, Christian
author_facet Abas, Lindy
Luschnig, Christian
author_sort Abas, Lindy
collection PubMed
description Isolation of a microsomal membrane fraction is a common procedure in studies involving membrane proteins. By conventional definition, microsomal membranes are collected by centrifugation of a postmitochondrial fraction at 100,000g in an ultracentrifuge, a method originally developed for large amounts of mammalian tissue. We present a method for isolating microsomal-type membranes from small amounts of Arabidopsis thaliana plant material that does not rely on ultracentrifugation but instead uses the lower relative centrifugal force (21,000g) of a microcentrifuge. We show that the 21,000g pellet is equivalent to that obtained at 100,000g and that it contains all of the membrane fractions expected in a conventional microsomal fraction. Our method incorporates specific manipulation of sample density throughout the procedure, with minimal preclearance, minimal volumes of extraction buffer, and minimal sedimentation pathlength. These features allow maximal membrane yields, enabling membrane isolation from limited amounts of material. We further demonstrate that conventional ultracentrifuge-based protocols give submaximal yields due to losses during early stages of the procedure; that is, extensive amounts of microsomal-type membranes can sediment prematurely during the typical preclearance steps. Our protocol avoids such losses, thereby ensuring maximal yield and a representative total membrane fraction. The principles of our method can be adapted for nonplant material.
format Online
Article
Text
id pubmed-3685806
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Academic Press
record_format MEDLINE/PubMed
spelling pubmed-36858062013-06-19 Maximum yields of microsomal-type membranes from small amounts of plant material without requiring ultracentrifugation Abas, Lindy Luschnig, Christian Anal Biochem Article Isolation of a microsomal membrane fraction is a common procedure in studies involving membrane proteins. By conventional definition, microsomal membranes are collected by centrifugation of a postmitochondrial fraction at 100,000g in an ultracentrifuge, a method originally developed for large amounts of mammalian tissue. We present a method for isolating microsomal-type membranes from small amounts of Arabidopsis thaliana plant material that does not rely on ultracentrifugation but instead uses the lower relative centrifugal force (21,000g) of a microcentrifuge. We show that the 21,000g pellet is equivalent to that obtained at 100,000g and that it contains all of the membrane fractions expected in a conventional microsomal fraction. Our method incorporates specific manipulation of sample density throughout the procedure, with minimal preclearance, minimal volumes of extraction buffer, and minimal sedimentation pathlength. These features allow maximal membrane yields, enabling membrane isolation from limited amounts of material. We further demonstrate that conventional ultracentrifuge-based protocols give submaximal yields due to losses during early stages of the procedure; that is, extensive amounts of microsomal-type membranes can sediment prematurely during the typical preclearance steps. Our protocol avoids such losses, thereby ensuring maximal yield and a representative total membrane fraction. The principles of our method can be adapted for nonplant material. Academic Press 2010-06-15 /pmc/articles/PMC3685806/ /pubmed/20193653 http://dx.doi.org/10.1016/j.ab.2010.02.030 Text en © 2010 Elsevier Inc. https://creativecommons.org/licenses/by-nc-nd/3.0/ Open Access under CC BY-NC-ND 3.0 (https://creativecommons.org/licenses/by-nc-nd/3.0/) license
spellingShingle Article
Abas, Lindy
Luschnig, Christian
Maximum yields of microsomal-type membranes from small amounts of plant material without requiring ultracentrifugation
title Maximum yields of microsomal-type membranes from small amounts of plant material without requiring ultracentrifugation
title_full Maximum yields of microsomal-type membranes from small amounts of plant material without requiring ultracentrifugation
title_fullStr Maximum yields of microsomal-type membranes from small amounts of plant material without requiring ultracentrifugation
title_full_unstemmed Maximum yields of microsomal-type membranes from small amounts of plant material without requiring ultracentrifugation
title_short Maximum yields of microsomal-type membranes from small amounts of plant material without requiring ultracentrifugation
title_sort maximum yields of microsomal-type membranes from small amounts of plant material without requiring ultracentrifugation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3685806/
https://www.ncbi.nlm.nih.gov/pubmed/20193653
http://dx.doi.org/10.1016/j.ab.2010.02.030
work_keys_str_mv AT abaslindy maximumyieldsofmicrosomaltypemembranesfromsmallamountsofplantmaterialwithoutrequiringultracentrifugation
AT luschnigchristian maximumyieldsofmicrosomaltypemembranesfromsmallamountsofplantmaterialwithoutrequiringultracentrifugation