Cargando…

Enhanced Archaerhodopsin Fluorescent Protein Voltage Indicators

A longstanding goal in neuroscience has been to develop techniques for imaging the voltage dynamics of genetically defined subsets of neurons. Optical sensors of transmembrane voltage would enhance studies of neural activity in contexts ranging from individual neurons cultured in vitro to neuronal p...

Descripción completa

Detalles Bibliográficos
Autores principales: Gong, Yiyang, Li, Jin Zhong, Schnitzer, Mark J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3686764/
https://www.ncbi.nlm.nih.gov/pubmed/23840563
http://dx.doi.org/10.1371/journal.pone.0066959
_version_ 1782273833817866240
author Gong, Yiyang
Li, Jin Zhong
Schnitzer, Mark J.
author_facet Gong, Yiyang
Li, Jin Zhong
Schnitzer, Mark J.
author_sort Gong, Yiyang
collection PubMed
description A longstanding goal in neuroscience has been to develop techniques for imaging the voltage dynamics of genetically defined subsets of neurons. Optical sensors of transmembrane voltage would enhance studies of neural activity in contexts ranging from individual neurons cultured in vitro to neuronal populations in awake-behaving animals. Recent progress has identified Archaerhodopsin (Arch) based sensors as a promising, genetically encoded class of fluorescent voltage indicators that can report single action potentials. Wild-type Arch exhibits sub-millisecond fluorescence responses to trans-membrane voltage, but its light-activated proton pump also responds to the imaging illumination. An Arch mutant (Arch-D95N) exhibits no photocurrent, but has a slower, ~40 ms response to voltage transients. Here we present Arch-derived voltage sensors with trafficking signals that enhance their localization to the neural membrane. We also describe Arch mutant sensors (Arch-EEN and -EEQ) that exhibit faster kinetics and greater fluorescence dynamic range than Arch-D95N, and no photocurrent at the illumination intensities normally used for imaging. We benchmarked these voltage sensors regarding their spike detection fidelity by using a signal detection theoretic framework that takes into account the experimentally measured photon shot noise and optical waveforms for single action potentials. This analysis revealed that by combining the sequence mutations and enhanced trafficking sequences, the new sensors improved the fidelity of spike detection by nearly three-fold in comparison to Arch-D95N.
format Online
Article
Text
id pubmed-3686764
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-36867642013-07-09 Enhanced Archaerhodopsin Fluorescent Protein Voltage Indicators Gong, Yiyang Li, Jin Zhong Schnitzer, Mark J. PLoS One Research Article A longstanding goal in neuroscience has been to develop techniques for imaging the voltage dynamics of genetically defined subsets of neurons. Optical sensors of transmembrane voltage would enhance studies of neural activity in contexts ranging from individual neurons cultured in vitro to neuronal populations in awake-behaving animals. Recent progress has identified Archaerhodopsin (Arch) based sensors as a promising, genetically encoded class of fluorescent voltage indicators that can report single action potentials. Wild-type Arch exhibits sub-millisecond fluorescence responses to trans-membrane voltage, but its light-activated proton pump also responds to the imaging illumination. An Arch mutant (Arch-D95N) exhibits no photocurrent, but has a slower, ~40 ms response to voltage transients. Here we present Arch-derived voltage sensors with trafficking signals that enhance their localization to the neural membrane. We also describe Arch mutant sensors (Arch-EEN and -EEQ) that exhibit faster kinetics and greater fluorescence dynamic range than Arch-D95N, and no photocurrent at the illumination intensities normally used for imaging. We benchmarked these voltage sensors regarding their spike detection fidelity by using a signal detection theoretic framework that takes into account the experimentally measured photon shot noise and optical waveforms for single action potentials. This analysis revealed that by combining the sequence mutations and enhanced trafficking sequences, the new sensors improved the fidelity of spike detection by nearly three-fold in comparison to Arch-D95N. Public Library of Science 2013-06-19 /pmc/articles/PMC3686764/ /pubmed/23840563 http://dx.doi.org/10.1371/journal.pone.0066959 Text en © 2013 Gong et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Gong, Yiyang
Li, Jin Zhong
Schnitzer, Mark J.
Enhanced Archaerhodopsin Fluorescent Protein Voltage Indicators
title Enhanced Archaerhodopsin Fluorescent Protein Voltage Indicators
title_full Enhanced Archaerhodopsin Fluorescent Protein Voltage Indicators
title_fullStr Enhanced Archaerhodopsin Fluorescent Protein Voltage Indicators
title_full_unstemmed Enhanced Archaerhodopsin Fluorescent Protein Voltage Indicators
title_short Enhanced Archaerhodopsin Fluorescent Protein Voltage Indicators
title_sort enhanced archaerhodopsin fluorescent protein voltage indicators
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3686764/
https://www.ncbi.nlm.nih.gov/pubmed/23840563
http://dx.doi.org/10.1371/journal.pone.0066959
work_keys_str_mv AT gongyiyang enhancedarchaerhodopsinfluorescentproteinvoltageindicators
AT lijinzhong enhancedarchaerhodopsinfluorescentproteinvoltageindicators
AT schnitzermarkj enhancedarchaerhodopsinfluorescentproteinvoltageindicators