Cargando…
A Validated RP-HPLC Method for the Estimation of Lapatinib in Tablet Dosage form using Gemcitabine Hydrochloride as an Internal Standard
A simple, selective, rapid, precise and economical reverse-phase high-performance liquid chromatography method has been developed for the determination of lapatinib in tablet using gemcitabine hydrochloride as an internal standard. Chromatography was carried out on an ODS C-18 RP column (4.6 mm i.d....
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3687931/ https://www.ncbi.nlm.nih.gov/pubmed/23798787 http://dx.doi.org/10.4103/0250-474X.110621 |
_version_ | 1782274017639530496 |
---|---|
author | Kumar, K. K. Nagoji, K. E. V. Nadh, R. V. |
author_facet | Kumar, K. K. Nagoji, K. E. V. Nadh, R. V. |
author_sort | Kumar, K. K. |
collection | PubMed |
description | A simple, selective, rapid, precise and economical reverse-phase high-performance liquid chromatography method has been developed for the determination of lapatinib in tablet using gemcitabine hydrochloride as an internal standard. Chromatography was carried out on an ODS C-18 RP column (4.6 mm i.d. ×250 mm) using a mixture of acetonitrile and water (50:50 v/v) as the mobile phase at a flow rate of 1.0 ml/min. The drug was monitored at 232 nm. The retention times for lapatinib and gemcitabine hydrochloride were found to be 4.25±0.05 and 6.10±0.05 min, respectively. The method produced linear responses in the concentration range of 2-60 μg/ml of lapatinib. The limit of detection and limit of quantitation were 0.265 and 0.884 μg/ml, respectively. |
format | Online Article Text |
id | pubmed-3687931 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-36879312013-06-24 A Validated RP-HPLC Method for the Estimation of Lapatinib in Tablet Dosage form using Gemcitabine Hydrochloride as an Internal Standard Kumar, K. K. Nagoji, K. E. V. Nadh, R. V. Indian J Pharm Sci Short Communication A simple, selective, rapid, precise and economical reverse-phase high-performance liquid chromatography method has been developed for the determination of lapatinib in tablet using gemcitabine hydrochloride as an internal standard. Chromatography was carried out on an ODS C-18 RP column (4.6 mm i.d. ×250 mm) using a mixture of acetonitrile and water (50:50 v/v) as the mobile phase at a flow rate of 1.0 ml/min. The drug was monitored at 232 nm. The retention times for lapatinib and gemcitabine hydrochloride were found to be 4.25±0.05 and 6.10±0.05 min, respectively. The method produced linear responses in the concentration range of 2-60 μg/ml of lapatinib. The limit of detection and limit of quantitation were 0.265 and 0.884 μg/ml, respectively. Medknow Publications & Media Pvt Ltd 2012 /pmc/articles/PMC3687931/ /pubmed/23798787 http://dx.doi.org/10.4103/0250-474X.110621 Text en Copyright: © Indian Journal of Pharmaceutical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Short Communication Kumar, K. K. Nagoji, K. E. V. Nadh, R. V. A Validated RP-HPLC Method for the Estimation of Lapatinib in Tablet Dosage form using Gemcitabine Hydrochloride as an Internal Standard |
title | A Validated RP-HPLC Method for the Estimation of Lapatinib in Tablet Dosage form using Gemcitabine Hydrochloride as an Internal Standard |
title_full | A Validated RP-HPLC Method for the Estimation of Lapatinib in Tablet Dosage form using Gemcitabine Hydrochloride as an Internal Standard |
title_fullStr | A Validated RP-HPLC Method for the Estimation of Lapatinib in Tablet Dosage form using Gemcitabine Hydrochloride as an Internal Standard |
title_full_unstemmed | A Validated RP-HPLC Method for the Estimation of Lapatinib in Tablet Dosage form using Gemcitabine Hydrochloride as an Internal Standard |
title_short | A Validated RP-HPLC Method for the Estimation of Lapatinib in Tablet Dosage form using Gemcitabine Hydrochloride as an Internal Standard |
title_sort | validated rp-hplc method for the estimation of lapatinib in tablet dosage form using gemcitabine hydrochloride as an internal standard |
topic | Short Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3687931/ https://www.ncbi.nlm.nih.gov/pubmed/23798787 http://dx.doi.org/10.4103/0250-474X.110621 |
work_keys_str_mv | AT kumarkk avalidatedrphplcmethodfortheestimationoflapatinibintabletdosageformusinggemcitabinehydrochlorideasaninternalstandard AT nagojikev avalidatedrphplcmethodfortheestimationoflapatinibintabletdosageformusinggemcitabinehydrochlorideasaninternalstandard AT nadhrv avalidatedrphplcmethodfortheestimationoflapatinibintabletdosageformusinggemcitabinehydrochlorideasaninternalstandard AT kumarkk validatedrphplcmethodfortheestimationoflapatinibintabletdosageformusinggemcitabinehydrochlorideasaninternalstandard AT nagojikev validatedrphplcmethodfortheestimationoflapatinibintabletdosageformusinggemcitabinehydrochlorideasaninternalstandard AT nadhrv validatedrphplcmethodfortheestimationoflapatinibintabletdosageformusinggemcitabinehydrochlorideasaninternalstandard |