Magnetic resonance of the heart in a muscular dystrophy patient with an MR conditional ICD: Assessment of safety, diagnostic value and technical limitations
Cardiovascular magnetic resonance (CMR) studies in patients with pacemakers or implantable cardioverter/defibrillators (ICD) are increasingly required in daily clinical practice. Therefore, in the last years the manufacturers developed not only MR-conditional pacemakers, but also MR-conditional ICDs...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3688460/ https://www.ncbi.nlm.nih.gov/pubmed/23758805 http://dx.doi.org/10.1186/1532-429X-15-49 |
_version_ | 1782476207646834688 |
---|---|
author | Florian, Anca Ludwig, Anna Rösch, Sabine Sechtem, Udo Yilmaz, Ali |
author_facet | Florian, Anca Ludwig, Anna Rösch, Sabine Sechtem, Udo Yilmaz, Ali |
author_sort | Florian, Anca |
collection | PubMed |
description | Cardiovascular magnetic resonance (CMR) studies in patients with pacemakers or implantable cardioverter/defibrillators (ICD) are increasingly required in daily clinical practice. Therefore, in the last years the manufacturers developed not only MR-conditional pacemakers, but also MR-conditional ICDs. However, the clinical experience regarding the feasibility and limitations of MR studies of the heart in patients with ICDs is still limited. In particular, there are hardly any CMR studies in the same patients performed prior to and post ICD implantation allowing a one-to-one comparison of the obtained CMR images. This is the first presentation of a CMR study in a patient with the world’s first and so far only MR-conditional ICD. In our case, a major problem related to the presence of the MR conditional ICD was an image artifact caused by the device’s generator which hampered the visualization of the midventricular and apical anterior and antero-lateral segments in all sequences performed. Considering previous studies, right chest implantation of the ICD could probably have helped in this setting and may be preferred in future ICD implantations. Our case report nicely illustrates the real clinical need for specially designed implantable devices that ensure safe and high-quality imaging in patients in whom serial CMR is required. |
format | Online Article Text |
id | pubmed-3688460 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-36884602013-06-21 Magnetic resonance of the heart in a muscular dystrophy patient with an MR conditional ICD: Assessment of safety, diagnostic value and technical limitations Florian, Anca Ludwig, Anna Rösch, Sabine Sechtem, Udo Yilmaz, Ali J Cardiovasc Magn Reson Case Report Cardiovascular magnetic resonance (CMR) studies in patients with pacemakers or implantable cardioverter/defibrillators (ICD) are increasingly required in daily clinical practice. Therefore, in the last years the manufacturers developed not only MR-conditional pacemakers, but also MR-conditional ICDs. However, the clinical experience regarding the feasibility and limitations of MR studies of the heart in patients with ICDs is still limited. In particular, there are hardly any CMR studies in the same patients performed prior to and post ICD implantation allowing a one-to-one comparison of the obtained CMR images. This is the first presentation of a CMR study in a patient with the world’s first and so far only MR-conditional ICD. In our case, a major problem related to the presence of the MR conditional ICD was an image artifact caused by the device’s generator which hampered the visualization of the midventricular and apical anterior and antero-lateral segments in all sequences performed. Considering previous studies, right chest implantation of the ICD could probably have helped in this setting and may be preferred in future ICD implantations. Our case report nicely illustrates the real clinical need for specially designed implantable devices that ensure safe and high-quality imaging in patients in whom serial CMR is required. BioMed Central 2013-06-11 /pmc/articles/PMC3688460/ /pubmed/23758805 http://dx.doi.org/10.1186/1532-429X-15-49 Text en Copyright © 2013 Florian et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Florian, Anca Ludwig, Anna Rösch, Sabine Sechtem, Udo Yilmaz, Ali Magnetic resonance of the heart in a muscular dystrophy patient with an MR conditional ICD: Assessment of safety, diagnostic value and technical limitations |
title | Magnetic resonance of the heart in a muscular dystrophy patient with an MR conditional ICD: Assessment of safety, diagnostic value and technical limitations |
title_full | Magnetic resonance of the heart in a muscular dystrophy patient with an MR conditional ICD: Assessment of safety, diagnostic value and technical limitations |
title_fullStr | Magnetic resonance of the heart in a muscular dystrophy patient with an MR conditional ICD: Assessment of safety, diagnostic value and technical limitations |
title_full_unstemmed | Magnetic resonance of the heart in a muscular dystrophy patient with an MR conditional ICD: Assessment of safety, diagnostic value and technical limitations |
title_short | Magnetic resonance of the heart in a muscular dystrophy patient with an MR conditional ICD: Assessment of safety, diagnostic value and technical limitations |
title_sort | magnetic resonance of the heart in a muscular dystrophy patient with an mr conditional icd: assessment of safety, diagnostic value and technical limitations |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3688460/ https://www.ncbi.nlm.nih.gov/pubmed/23758805 http://dx.doi.org/10.1186/1532-429X-15-49 |
work_keys_str_mv | AT floriananca magneticresonanceoftheheartinamusculardystrophypatientwithanmrconditionalicdassessmentofsafetydiagnosticvalueandtechnicallimitations AT ludwiganna magneticresonanceoftheheartinamusculardystrophypatientwithanmrconditionalicdassessmentofsafetydiagnosticvalueandtechnicallimitations AT roschsabine magneticresonanceoftheheartinamusculardystrophypatientwithanmrconditionalicdassessmentofsafetydiagnosticvalueandtechnicallimitations AT sechtemudo magneticresonanceoftheheartinamusculardystrophypatientwithanmrconditionalicdassessmentofsafetydiagnosticvalueandtechnicallimitations AT yilmazali magneticresonanceoftheheartinamusculardystrophypatientwithanmrconditionalicdassessmentofsafetydiagnosticvalueandtechnicallimitations |