Cargando…

High-Sensitive Troponin Measurement in Emergency Department Patients Presenting with Syncope: A Retrospective Analysis

OBJECTIVE: To study the relevance of high-sensitive troponin measurements in the acute workup in patients admitted to the emergency department of a large university hospital due to syncope. METHODS: In this retrospective study all patients admitted to the emergency department because of syncope of t...

Descripción completa

Detalles Bibliográficos
Autores principales: Lindner, Gregor, Pfortmueller, Carmen A., Funk, Georg-Christian, Leichtle, Alexander B., Fiedler, Georg Martin, Exadaktylos, Aristomenis K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3688899/
https://www.ncbi.nlm.nih.gov/pubmed/23823330
http://dx.doi.org/10.1371/journal.pone.0066470
_version_ 1782274191080292352
author Lindner, Gregor
Pfortmueller, Carmen A.
Funk, Georg-Christian
Leichtle, Alexander B.
Fiedler, Georg Martin
Exadaktylos, Aristomenis K.
author_facet Lindner, Gregor
Pfortmueller, Carmen A.
Funk, Georg-Christian
Leichtle, Alexander B.
Fiedler, Georg Martin
Exadaktylos, Aristomenis K.
author_sort Lindner, Gregor
collection PubMed
description OBJECTIVE: To study the relevance of high-sensitive troponin measurements in the acute workup in patients admitted to the emergency department of a large university hospital due to syncope. METHODS: In this retrospective study all patients admitted to the emergency department because of syncope of the Inselspital, University Hospital Bern between 01 August 2010 and 31 October 2012, with serial determination of high-sensitive troponin (baseline and three hours control) were included. Of all identified patients we obtained data on demographics, laboratory data, ECG as well as on outcome. A change in high-sensitive troponin in the three hours control of +/−30% compared to baseline was considered significant. RESULTS: A total of 121 patients with a mean age of 67 years (SD 16) were included in the study. 79 patients (65%) were male and 42 (35%) were female. There was no significant difference in the median high sensitive-troponin level at baseline and in the three hours control (0.01 mcg/L [0.003 to 0.022] versus 0.011 mcg/L [0.003 to 0.022], p = 0.47). Median percent change in high-sensitive troponin level between baseline and control was 0% (−9.1 to 5). 51 patients (42%) had elevated high-sensitive troponin levels at baseline with 7 patients (6%) showing a dynamic of +/−30% change from the baseline measurement in the 3 hours control. 3 of these patients received coronary angiography due to the dynamic in high-sensitive troponin, none of whom needed intervention for coronary revascularization. CONCLUSIONS: On basis of the current study, where no single patient took benefit from determination of high-sensitive troponin, measurement of cardiac troponins should be reserved for patients with syncope presenting with symptoms suggestive for the presence of an acute cardiac syndrome.
format Online
Article
Text
id pubmed-3688899
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-36888992013-07-02 High-Sensitive Troponin Measurement in Emergency Department Patients Presenting with Syncope: A Retrospective Analysis Lindner, Gregor Pfortmueller, Carmen A. Funk, Georg-Christian Leichtle, Alexander B. Fiedler, Georg Martin Exadaktylos, Aristomenis K. PLoS One Research Article OBJECTIVE: To study the relevance of high-sensitive troponin measurements in the acute workup in patients admitted to the emergency department of a large university hospital due to syncope. METHODS: In this retrospective study all patients admitted to the emergency department because of syncope of the Inselspital, University Hospital Bern between 01 August 2010 and 31 October 2012, with serial determination of high-sensitive troponin (baseline and three hours control) were included. Of all identified patients we obtained data on demographics, laboratory data, ECG as well as on outcome. A change in high-sensitive troponin in the three hours control of +/−30% compared to baseline was considered significant. RESULTS: A total of 121 patients with a mean age of 67 years (SD 16) were included in the study. 79 patients (65%) were male and 42 (35%) were female. There was no significant difference in the median high sensitive-troponin level at baseline and in the three hours control (0.01 mcg/L [0.003 to 0.022] versus 0.011 mcg/L [0.003 to 0.022], p = 0.47). Median percent change in high-sensitive troponin level between baseline and control was 0% (−9.1 to 5). 51 patients (42%) had elevated high-sensitive troponin levels at baseline with 7 patients (6%) showing a dynamic of +/−30% change from the baseline measurement in the 3 hours control. 3 of these patients received coronary angiography due to the dynamic in high-sensitive troponin, none of whom needed intervention for coronary revascularization. CONCLUSIONS: On basis of the current study, where no single patient took benefit from determination of high-sensitive troponin, measurement of cardiac troponins should be reserved for patients with syncope presenting with symptoms suggestive for the presence of an acute cardiac syndrome. Public Library of Science 2013-06-18 /pmc/articles/PMC3688899/ /pubmed/23823330 http://dx.doi.org/10.1371/journal.pone.0066470 Text en © 2013 Lindner et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Lindner, Gregor
Pfortmueller, Carmen A.
Funk, Georg-Christian
Leichtle, Alexander B.
Fiedler, Georg Martin
Exadaktylos, Aristomenis K.
High-Sensitive Troponin Measurement in Emergency Department Patients Presenting with Syncope: A Retrospective Analysis
title High-Sensitive Troponin Measurement in Emergency Department Patients Presenting with Syncope: A Retrospective Analysis
title_full High-Sensitive Troponin Measurement in Emergency Department Patients Presenting with Syncope: A Retrospective Analysis
title_fullStr High-Sensitive Troponin Measurement in Emergency Department Patients Presenting with Syncope: A Retrospective Analysis
title_full_unstemmed High-Sensitive Troponin Measurement in Emergency Department Patients Presenting with Syncope: A Retrospective Analysis
title_short High-Sensitive Troponin Measurement in Emergency Department Patients Presenting with Syncope: A Retrospective Analysis
title_sort high-sensitive troponin measurement in emergency department patients presenting with syncope: a retrospective analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3688899/
https://www.ncbi.nlm.nih.gov/pubmed/23823330
http://dx.doi.org/10.1371/journal.pone.0066470
work_keys_str_mv AT lindnergregor highsensitivetroponinmeasurementinemergencydepartmentpatientspresentingwithsyncopearetrospectiveanalysis
AT pfortmuellercarmena highsensitivetroponinmeasurementinemergencydepartmentpatientspresentingwithsyncopearetrospectiveanalysis
AT funkgeorgchristian highsensitivetroponinmeasurementinemergencydepartmentpatientspresentingwithsyncopearetrospectiveanalysis
AT leichtlealexanderb highsensitivetroponinmeasurementinemergencydepartmentpatientspresentingwithsyncopearetrospectiveanalysis
AT fiedlergeorgmartin highsensitivetroponinmeasurementinemergencydepartmentpatientspresentingwithsyncopearetrospectiveanalysis
AT exadaktylosaristomenisk highsensitivetroponinmeasurementinemergencydepartmentpatientspresentingwithsyncopearetrospectiveanalysis