Analysis of linear measurement accuracy obtained by cone beam computed tomography (CBCT-NewTom VG)

BACKGROUND: One of the major uses of cone beam computed tomography (CBCT) is presurgical implant planning. Linear measurement is used for the determination of the quantity of alveolar bone (height and width). Linear measurements are used in orthodontic analysis and definition of jaw tumor size. The...

Descripción completa

Detalles Bibliográficos
Autores principales: Moshfeghi, Mahkameh, Tavakoli, Mohammad Amin, Hosseini, Ehsan Tavakoli, Hosseini, Ali Tavakoli, Hosseini, Iman Tavakoli
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3692201/
https://www.ncbi.nlm.nih.gov/pubmed/23814563
_version_ 1782274593433583616
author Moshfeghi, Mahkameh
Tavakoli, Mohammad Amin
Hosseini, Ehsan Tavakoli
Hosseini, Ali Tavakoli
Hosseini, Iman Tavakoli
author_facet Moshfeghi, Mahkameh
Tavakoli, Mohammad Amin
Hosseini, Ehsan Tavakoli
Hosseini, Ali Tavakoli
Hosseini, Iman Tavakoli
author_sort Moshfeghi, Mahkameh
collection PubMed
description BACKGROUND: One of the major uses of cone beam computed tomography (CBCT) is presurgical implant planning. Linear measurement is used for the determination of the quantity of alveolar bone (height and width). Linear measurements are used in orthodontic analysis and definition of jaw tumor size. The objective of this study is to evaluate the accuracy of the linear measurement of CBCT (Newtom VG) in the axial and coronal planes, with two different voxel sizes. MATERIALS AND METHODS: In this accuracy diagnostic study, 22 anatomic landmarks in four dry human skulls were marked by gutta-percha. Fifteen linear measurements were obtained using a digital caliper. These were considered to be the gold standard (real measurement). The skulls were scanned by CBCT (Newtom VG) at two settings: (a) Voxel size 0.3 mm (b) voxel size 0.15 mm High Resolution (HR). The radiographic distance measurements were made in the axial and coronal sections by three observers. The radiographic measurements were repeated two weeks later for evaluation of intraobserver reliability. SPSS software version 17 was used for data analysis. The level of significance was considered to be 5% (P ≤ 0.05). RESULTS: The mean differences of real and radiographic measurements were -0.10±0.99 mm in the axial sections, -0.27±1.07 mm in the coronal sections, +0.14±1.44 mm in the axial (HR) sections, and 0.02±1.4 mm in the coronal (HR) sections. The intraclass correlation (ICC) for CBCT measurements in the axial sections was 0.9944, coronal sections 0.9941, axial (HR) sections 0.9935, and coronal (HR) sections 0.9937. The statistical analysis showed high interobserver and intraobserver reliability (P ≤ 0.05). CONCLUSION: CBCT (Newtom VG) is highly accurate and reproducible in linear measurements in the axial and coronal image planes and in different areas of the maxillofacial region. According to the findings of the present study, a CBCT scan with a larger voxel size (0.3 mm in comparison to 0.15 mm) is recommended when the purpose of the CBCT scan is to measure linear distances. This will result in lower patient radiation dose and faster scan time.
format Online
Article
Text
id pubmed-3692201
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-36922012013-06-28 Analysis of linear measurement accuracy obtained by cone beam computed tomography (CBCT-NewTom VG) Moshfeghi, Mahkameh Tavakoli, Mohammad Amin Hosseini, Ehsan Tavakoli Hosseini, Ali Tavakoli Hosseini, Iman Tavakoli Dent Res J (Isfahan) Original Article BACKGROUND: One of the major uses of cone beam computed tomography (CBCT) is presurgical implant planning. Linear measurement is used for the determination of the quantity of alveolar bone (height and width). Linear measurements are used in orthodontic analysis and definition of jaw tumor size. The objective of this study is to evaluate the accuracy of the linear measurement of CBCT (Newtom VG) in the axial and coronal planes, with two different voxel sizes. MATERIALS AND METHODS: In this accuracy diagnostic study, 22 anatomic landmarks in four dry human skulls were marked by gutta-percha. Fifteen linear measurements were obtained using a digital caliper. These were considered to be the gold standard (real measurement). The skulls were scanned by CBCT (Newtom VG) at two settings: (a) Voxel size 0.3 mm (b) voxel size 0.15 mm High Resolution (HR). The radiographic distance measurements were made in the axial and coronal sections by three observers. The radiographic measurements were repeated two weeks later for evaluation of intraobserver reliability. SPSS software version 17 was used for data analysis. The level of significance was considered to be 5% (P ≤ 0.05). RESULTS: The mean differences of real and radiographic measurements were -0.10±0.99 mm in the axial sections, -0.27±1.07 mm in the coronal sections, +0.14±1.44 mm in the axial (HR) sections, and 0.02±1.4 mm in the coronal (HR) sections. The intraclass correlation (ICC) for CBCT measurements in the axial sections was 0.9944, coronal sections 0.9941, axial (HR) sections 0.9935, and coronal (HR) sections 0.9937. The statistical analysis showed high interobserver and intraobserver reliability (P ≤ 0.05). CONCLUSION: CBCT (Newtom VG) is highly accurate and reproducible in linear measurements in the axial and coronal image planes and in different areas of the maxillofacial region. According to the findings of the present study, a CBCT scan with a larger voxel size (0.3 mm in comparison to 0.15 mm) is recommended when the purpose of the CBCT scan is to measure linear distances. This will result in lower patient radiation dose and faster scan time. Medknow Publications & Media Pvt Ltd 2012-12 /pmc/articles/PMC3692201/ /pubmed/23814563 Text en Copyright: © Dental Research Journal http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Moshfeghi, Mahkameh
Tavakoli, Mohammad Amin
Hosseini, Ehsan Tavakoli
Hosseini, Ali Tavakoli
Hosseini, Iman Tavakoli
Analysis of linear measurement accuracy obtained by cone beam computed tomography (CBCT-NewTom VG)
title Analysis of linear measurement accuracy obtained by cone beam computed tomography (CBCT-NewTom VG)
title_full Analysis of linear measurement accuracy obtained by cone beam computed tomography (CBCT-NewTom VG)
title_fullStr Analysis of linear measurement accuracy obtained by cone beam computed tomography (CBCT-NewTom VG)
title_full_unstemmed Analysis of linear measurement accuracy obtained by cone beam computed tomography (CBCT-NewTom VG)
title_short Analysis of linear measurement accuracy obtained by cone beam computed tomography (CBCT-NewTom VG)
title_sort analysis of linear measurement accuracy obtained by cone beam computed tomography (cbct-newtom vg)
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3692201/
https://www.ncbi.nlm.nih.gov/pubmed/23814563
work_keys_str_mv AT moshfeghimahkameh analysisoflinearmeasurementaccuracyobtainedbyconebeamcomputedtomographycbctnewtomvg
AT tavakolimohammadamin analysisoflinearmeasurementaccuracyobtainedbyconebeamcomputedtomographycbctnewtomvg
AT hosseiniehsantavakoli analysisoflinearmeasurementaccuracyobtainedbyconebeamcomputedtomographycbctnewtomvg
AT hosseinialitavakoli analysisoflinearmeasurementaccuracyobtainedbyconebeamcomputedtomographycbctnewtomvg
AT hosseiniimantavakoli analysisoflinearmeasurementaccuracyobtainedbyconebeamcomputedtomographycbctnewtomvg