Cargando…
Comparison of (99m)Tc-N-DBODC5 and (99m)Tc-MIBI of Myocardial Perfusion Imaging for Diagnosis of Coronary Artery Disease
Despite recent advances in therapeutic and diagnostic approaches, coronary artery disease (CAD) and its related cardiac disorders represent the most common cause of death in the United States. Nuclear myocardial perfusion imaging (MPI) technologies play a pivotal role in the diagnosis and treatment...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3693116/ https://www.ncbi.nlm.nih.gov/pubmed/23841052 http://dx.doi.org/10.1155/2013/145427 |
_version_ | 1782274708021968896 |
---|---|
author | Ma, Haiyan Li, Sijin Wu, Zhifang Liu, Jianzhong Liu, Haiyan Guo, Xiaoshan |
author_facet | Ma, Haiyan Li, Sijin Wu, Zhifang Liu, Jianzhong Liu, Haiyan Guo, Xiaoshan |
author_sort | Ma, Haiyan |
collection | PubMed |
description | Despite recent advances in therapeutic and diagnostic approaches, coronary artery disease (CAD) and its related cardiac disorders represent the most common cause of death in the United States. Nuclear myocardial perfusion imaging (MPI) technologies play a pivotal role in the diagnosis and treatment design for CAD. Recently, in order to develop improved MPI agents for diagnosis of CAD, (99m)Tc-[bis(dimethoxypropylphosphinoethyl)-ethoxyethyl-amine(PNP5)]-[bis(N-ethoxyethyl)dithiocarbamato(DBODC)]nitride(N-DBODC5)((99m)Tc-N-DBODC5) with a faster liver clearance than conventional single-photon emission computed tomography (SPECT) imaging agents (technetium 99m sestamibi ((99m)Tc-MIBI) or technetium 99m tetrofosmin) has been introduced. In preclinical and phase I studies, (99m)Tc-N-DBODC5 has shown characteristics of an essentially ideal MPI tracer. Importantly, however, there is no data to support the use of (99m)Tc-N-DBODC5 to evaluate myocardial ischemia in patients with suspected CAD. The present study was designed to assess the clinical value of this agent; the findings of stress and rest MPI after the administration of this agent were compared to those of stress and rest (99m)Tc-MIBI, as well as those of coronary angiography, with respect to the detection of CAD. Our findings indicated the usefulness of (99m)Tc-N-DBODC5 as a promising MPI agent. |
format | Online Article Text |
id | pubmed-3693116 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-36931162013-07-09 Comparison of (99m)Tc-N-DBODC5 and (99m)Tc-MIBI of Myocardial Perfusion Imaging for Diagnosis of Coronary Artery Disease Ma, Haiyan Li, Sijin Wu, Zhifang Liu, Jianzhong Liu, Haiyan Guo, Xiaoshan Biomed Res Int Clinical Study Despite recent advances in therapeutic and diagnostic approaches, coronary artery disease (CAD) and its related cardiac disorders represent the most common cause of death in the United States. Nuclear myocardial perfusion imaging (MPI) technologies play a pivotal role in the diagnosis and treatment design for CAD. Recently, in order to develop improved MPI agents for diagnosis of CAD, (99m)Tc-[bis(dimethoxypropylphosphinoethyl)-ethoxyethyl-amine(PNP5)]-[bis(N-ethoxyethyl)dithiocarbamato(DBODC)]nitride(N-DBODC5)((99m)Tc-N-DBODC5) with a faster liver clearance than conventional single-photon emission computed tomography (SPECT) imaging agents (technetium 99m sestamibi ((99m)Tc-MIBI) or technetium 99m tetrofosmin) has been introduced. In preclinical and phase I studies, (99m)Tc-N-DBODC5 has shown characteristics of an essentially ideal MPI tracer. Importantly, however, there is no data to support the use of (99m)Tc-N-DBODC5 to evaluate myocardial ischemia in patients with suspected CAD. The present study was designed to assess the clinical value of this agent; the findings of stress and rest MPI after the administration of this agent were compared to those of stress and rest (99m)Tc-MIBI, as well as those of coronary angiography, with respect to the detection of CAD. Our findings indicated the usefulness of (99m)Tc-N-DBODC5 as a promising MPI agent. Hindawi Publishing Corporation 2013 2013-06-11 /pmc/articles/PMC3693116/ /pubmed/23841052 http://dx.doi.org/10.1155/2013/145427 Text en Copyright © 2013 Haiyan Ma et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Study Ma, Haiyan Li, Sijin Wu, Zhifang Liu, Jianzhong Liu, Haiyan Guo, Xiaoshan Comparison of (99m)Tc-N-DBODC5 and (99m)Tc-MIBI of Myocardial Perfusion Imaging for Diagnosis of Coronary Artery Disease |
title | Comparison of (99m)Tc-N-DBODC5 and (99m)Tc-MIBI of Myocardial Perfusion Imaging for Diagnosis of Coronary Artery Disease |
title_full | Comparison of (99m)Tc-N-DBODC5 and (99m)Tc-MIBI of Myocardial Perfusion Imaging for Diagnosis of Coronary Artery Disease |
title_fullStr | Comparison of (99m)Tc-N-DBODC5 and (99m)Tc-MIBI of Myocardial Perfusion Imaging for Diagnosis of Coronary Artery Disease |
title_full_unstemmed | Comparison of (99m)Tc-N-DBODC5 and (99m)Tc-MIBI of Myocardial Perfusion Imaging for Diagnosis of Coronary Artery Disease |
title_short | Comparison of (99m)Tc-N-DBODC5 and (99m)Tc-MIBI of Myocardial Perfusion Imaging for Diagnosis of Coronary Artery Disease |
title_sort | comparison of (99m)tc-n-dbodc5 and (99m)tc-mibi of myocardial perfusion imaging for diagnosis of coronary artery disease |
topic | Clinical Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3693116/ https://www.ncbi.nlm.nih.gov/pubmed/23841052 http://dx.doi.org/10.1155/2013/145427 |
work_keys_str_mv | AT mahaiyan comparisonof99mtcndbodc5and99mtcmibiofmyocardialperfusionimagingfordiagnosisofcoronaryarterydisease AT lisijin comparisonof99mtcndbodc5and99mtcmibiofmyocardialperfusionimagingfordiagnosisofcoronaryarterydisease AT wuzhifang comparisonof99mtcndbodc5and99mtcmibiofmyocardialperfusionimagingfordiagnosisofcoronaryarterydisease AT liujianzhong comparisonof99mtcndbodc5and99mtcmibiofmyocardialperfusionimagingfordiagnosisofcoronaryarterydisease AT liuhaiyan comparisonof99mtcndbodc5and99mtcmibiofmyocardialperfusionimagingfordiagnosisofcoronaryarterydisease AT guoxiaoshan comparisonof99mtcndbodc5and99mtcmibiofmyocardialperfusionimagingfordiagnosisofcoronaryarterydisease |