Cargando…

Effects of X-Ray Dose On Rhizosphere Studies Using X-Ray Computed Tomography

X-ray Computed Tomography (CT) is a non-destructive imaging technique originally designed for diagnostic medicine, which was adopted for rhizosphere and soil science applications in the early 1980s. X-ray CT enables researchers to simultaneously visualise and quantify the heterogeneous soil matrix o...

Descripción completa

Detalles Bibliográficos
Autores principales: Zappala, Susan, Helliwell, Jonathan R., Tracy, Saoirse R., Mairhofer, Stefan, Sturrock, Craig J., Pridmore, Tony, Bennett, Malcolm, Mooney, Sacha J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3693932/
https://www.ncbi.nlm.nih.gov/pubmed/23840640
http://dx.doi.org/10.1371/journal.pone.0067250
_version_ 1782274776577867776
author Zappala, Susan
Helliwell, Jonathan R.
Tracy, Saoirse R.
Mairhofer, Stefan
Sturrock, Craig J.
Pridmore, Tony
Bennett, Malcolm
Mooney, Sacha J.
author_facet Zappala, Susan
Helliwell, Jonathan R.
Tracy, Saoirse R.
Mairhofer, Stefan
Sturrock, Craig J.
Pridmore, Tony
Bennett, Malcolm
Mooney, Sacha J.
author_sort Zappala, Susan
collection PubMed
description X-ray Computed Tomography (CT) is a non-destructive imaging technique originally designed for diagnostic medicine, which was adopted for rhizosphere and soil science applications in the early 1980s. X-ray CT enables researchers to simultaneously visualise and quantify the heterogeneous soil matrix of mineral grains, organic matter, air-filled pores and water-filled pores. Additionally, X-ray CT allows visualisation of plant roots in situ without the need for traditional invasive methods such as root washing. However, one routinely unreported aspect of X-ray CT is the potential effect of X-ray dose on the soil-borne microorganisms and plants in rhizosphere investigations. Here we aimed to i) highlight the need for more consistent reporting of X-ray CT parameters for dose to sample, ii) to provide an overview of previously reported impacts of X-rays on soil microorganisms and plant roots and iii) present new data investigating the response of plant roots and microbial communities to X-ray exposure. Fewer than 5% of the 126 publications included in the literature review contained sufficient information to calculate dose and only 2.4% of the publications explicitly state an estimate of dose received by each sample. We conducted a study involving rice roots growing in soil, observing no significant difference between the numbers of root tips, root volume and total root length in scanned versus unscanned samples. In parallel, a soil microbe experiment scanning samples over a total of 24 weeks observed no significant difference between the scanned and unscanned microbial biomass values. We conclude from the literature review and our own experiments that X-ray CT does not impact plant growth or soil microbial populations when employing a low level of dose (<30 Gy). However, the call for higher throughput X-ray CT means that doses that biological samples receive are likely to increase and thus should be closely monitored.
format Online
Article
Text
id pubmed-3693932
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-36939322013-07-09 Effects of X-Ray Dose On Rhizosphere Studies Using X-Ray Computed Tomography Zappala, Susan Helliwell, Jonathan R. Tracy, Saoirse R. Mairhofer, Stefan Sturrock, Craig J. Pridmore, Tony Bennett, Malcolm Mooney, Sacha J. PLoS One Research Article X-ray Computed Tomography (CT) is a non-destructive imaging technique originally designed for diagnostic medicine, which was adopted for rhizosphere and soil science applications in the early 1980s. X-ray CT enables researchers to simultaneously visualise and quantify the heterogeneous soil matrix of mineral grains, organic matter, air-filled pores and water-filled pores. Additionally, X-ray CT allows visualisation of plant roots in situ without the need for traditional invasive methods such as root washing. However, one routinely unreported aspect of X-ray CT is the potential effect of X-ray dose on the soil-borne microorganisms and plants in rhizosphere investigations. Here we aimed to i) highlight the need for more consistent reporting of X-ray CT parameters for dose to sample, ii) to provide an overview of previously reported impacts of X-rays on soil microorganisms and plant roots and iii) present new data investigating the response of plant roots and microbial communities to X-ray exposure. Fewer than 5% of the 126 publications included in the literature review contained sufficient information to calculate dose and only 2.4% of the publications explicitly state an estimate of dose received by each sample. We conducted a study involving rice roots growing in soil, observing no significant difference between the numbers of root tips, root volume and total root length in scanned versus unscanned samples. In parallel, a soil microbe experiment scanning samples over a total of 24 weeks observed no significant difference between the scanned and unscanned microbial biomass values. We conclude from the literature review and our own experiments that X-ray CT does not impact plant growth or soil microbial populations when employing a low level of dose (<30 Gy). However, the call for higher throughput X-ray CT means that doses that biological samples receive are likely to increase and thus should be closely monitored. Public Library of Science 2013-06-26 /pmc/articles/PMC3693932/ /pubmed/23840640 http://dx.doi.org/10.1371/journal.pone.0067250 Text en © 2013 Zappala et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Zappala, Susan
Helliwell, Jonathan R.
Tracy, Saoirse R.
Mairhofer, Stefan
Sturrock, Craig J.
Pridmore, Tony
Bennett, Malcolm
Mooney, Sacha J.
Effects of X-Ray Dose On Rhizosphere Studies Using X-Ray Computed Tomography
title Effects of X-Ray Dose On Rhizosphere Studies Using X-Ray Computed Tomography
title_full Effects of X-Ray Dose On Rhizosphere Studies Using X-Ray Computed Tomography
title_fullStr Effects of X-Ray Dose On Rhizosphere Studies Using X-Ray Computed Tomography
title_full_unstemmed Effects of X-Ray Dose On Rhizosphere Studies Using X-Ray Computed Tomography
title_short Effects of X-Ray Dose On Rhizosphere Studies Using X-Ray Computed Tomography
title_sort effects of x-ray dose on rhizosphere studies using x-ray computed tomography
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3693932/
https://www.ncbi.nlm.nih.gov/pubmed/23840640
http://dx.doi.org/10.1371/journal.pone.0067250
work_keys_str_mv AT zappalasusan effectsofxraydoseonrhizospherestudiesusingxraycomputedtomography
AT helliwelljonathanr effectsofxraydoseonrhizospherestudiesusingxraycomputedtomography
AT tracysaoirser effectsofxraydoseonrhizospherestudiesusingxraycomputedtomography
AT mairhoferstefan effectsofxraydoseonrhizospherestudiesusingxraycomputedtomography
AT sturrockcraigj effectsofxraydoseonrhizospherestudiesusingxraycomputedtomography
AT pridmoretony effectsofxraydoseonrhizospherestudiesusingxraycomputedtomography
AT bennettmalcolm effectsofxraydoseonrhizospherestudiesusingxraycomputedtomography
AT mooneysachaj effectsofxraydoseonrhizospherestudiesusingxraycomputedtomography