Cargando…

Retinal Thickness Normative Data in Wild-Type Mice Using Customized Miniature SD-OCT

OBJECTIVE: To report normative data for retinal thickness in wild-type C57BL/6 mouse utilizing a miniature SD-OCT system. METHODS: Thirty adult mice (range: 3–5 months) were anesthetized and secured into the Bioptigen Spectral Domain Ophthalmic Imaging System. Right eye SD-OCT images were standardiz...

Descripción completa

Detalles Bibliográficos
Autores principales: Ferguson, Lee R., Dominguez II, James M., Balaiya, Sankarathi, Grover, Sandeep, Chalam, Kakarla V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3695045/
https://www.ncbi.nlm.nih.gov/pubmed/23826252
http://dx.doi.org/10.1371/journal.pone.0067265
_version_ 1782274933490974720
author Ferguson, Lee R.
Dominguez II, James M.
Balaiya, Sankarathi
Grover, Sandeep
Chalam, Kakarla V.
author_facet Ferguson, Lee R.
Dominguez II, James M.
Balaiya, Sankarathi
Grover, Sandeep
Chalam, Kakarla V.
author_sort Ferguson, Lee R.
collection PubMed
description OBJECTIVE: To report normative data for retinal thickness in wild-type C57BL/6 mouse utilizing a miniature SD-OCT system. METHODS: Thirty adult mice (range: 3–5 months) were anesthetized and secured into the Bioptigen Spectral Domain Ophthalmic Imaging System. Right eye SD-OCT images were standardized by centralizing the optic nerve head (ONH) prior to image acquisition. Global and quadrant total retinal thickness (TRT) values were measured from retinal nerve fiber layer to retinal pigment epithelial layer. Posterior segment analyses also included the outer retinal layer (ORL) and inner retinal layer (IRL). Further sublayer analyses of four layers from the ORL and three layers comprising the IRL were also performed. RESULTS: The overall mean±SD global TRT in a C57BL/6 mouse model was 204.41±5.19 µm. Quadrant mean TRT values were 204.85±5.81 µm inferiorly, 204.97±6.71 µm nasally, 205.08±5.44 µm temporally, and 202.74±4.85 µm superiorly. Mean±SD thickness for ORL, and IRL were 126.37±10.01 µm, and 107.03±10.98 µm respectively. The mean±SD estimates for the four layers of the ORL were 18.23±2.73 µm, 26.04±4.21 µm, 63.8±6.23 µm, and 19.22±4.34 µm. Mean±SD values for the three IRL sublayers were 27.82±4.04 µm, 59.62±6.66 µm and 19.12±3.71 µm. CONCLUSION: This study established normative values for the total retinal thickness and sublayer thickness for the wild-type C57BL/6 mice. Moreover, it provides a standard of retinal morphology, in a commonly used animal model, for evaluating therapeutic interventions and retinal disease pathophysiology.
format Online
Article
Text
id pubmed-3695045
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-36950452013-07-03 Retinal Thickness Normative Data in Wild-Type Mice Using Customized Miniature SD-OCT Ferguson, Lee R. Dominguez II, James M. Balaiya, Sankarathi Grover, Sandeep Chalam, Kakarla V. PLoS One Research Article OBJECTIVE: To report normative data for retinal thickness in wild-type C57BL/6 mouse utilizing a miniature SD-OCT system. METHODS: Thirty adult mice (range: 3–5 months) were anesthetized and secured into the Bioptigen Spectral Domain Ophthalmic Imaging System. Right eye SD-OCT images were standardized by centralizing the optic nerve head (ONH) prior to image acquisition. Global and quadrant total retinal thickness (TRT) values were measured from retinal nerve fiber layer to retinal pigment epithelial layer. Posterior segment analyses also included the outer retinal layer (ORL) and inner retinal layer (IRL). Further sublayer analyses of four layers from the ORL and three layers comprising the IRL were also performed. RESULTS: The overall mean±SD global TRT in a C57BL/6 mouse model was 204.41±5.19 µm. Quadrant mean TRT values were 204.85±5.81 µm inferiorly, 204.97±6.71 µm nasally, 205.08±5.44 µm temporally, and 202.74±4.85 µm superiorly. Mean±SD thickness for ORL, and IRL were 126.37±10.01 µm, and 107.03±10.98 µm respectively. The mean±SD estimates for the four layers of the ORL were 18.23±2.73 µm, 26.04±4.21 µm, 63.8±6.23 µm, and 19.22±4.34 µm. Mean±SD values for the three IRL sublayers were 27.82±4.04 µm, 59.62±6.66 µm and 19.12±3.71 µm. CONCLUSION: This study established normative values for the total retinal thickness and sublayer thickness for the wild-type C57BL/6 mice. Moreover, it provides a standard of retinal morphology, in a commonly used animal model, for evaluating therapeutic interventions and retinal disease pathophysiology. Public Library of Science 2013-06-27 /pmc/articles/PMC3695045/ /pubmed/23826252 http://dx.doi.org/10.1371/journal.pone.0067265 Text en © 2013 Ferguson et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Ferguson, Lee R.
Dominguez II, James M.
Balaiya, Sankarathi
Grover, Sandeep
Chalam, Kakarla V.
Retinal Thickness Normative Data in Wild-Type Mice Using Customized Miniature SD-OCT
title Retinal Thickness Normative Data in Wild-Type Mice Using Customized Miniature SD-OCT
title_full Retinal Thickness Normative Data in Wild-Type Mice Using Customized Miniature SD-OCT
title_fullStr Retinal Thickness Normative Data in Wild-Type Mice Using Customized Miniature SD-OCT
title_full_unstemmed Retinal Thickness Normative Data in Wild-Type Mice Using Customized Miniature SD-OCT
title_short Retinal Thickness Normative Data in Wild-Type Mice Using Customized Miniature SD-OCT
title_sort retinal thickness normative data in wild-type mice using customized miniature sd-oct
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3695045/
https://www.ncbi.nlm.nih.gov/pubmed/23826252
http://dx.doi.org/10.1371/journal.pone.0067265
work_keys_str_mv AT fergusonleer retinalthicknessnormativedatainwildtypemiceusingcustomizedminiaturesdoct
AT domingueziijamesm retinalthicknessnormativedatainwildtypemiceusingcustomizedminiaturesdoct
AT balaiyasankarathi retinalthicknessnormativedatainwildtypemiceusingcustomizedminiaturesdoct
AT groversandeep retinalthicknessnormativedatainwildtypemiceusingcustomizedminiaturesdoct
AT chalamkakarlav retinalthicknessnormativedatainwildtypemiceusingcustomizedminiaturesdoct