Cargando…

Comparison of 24-h Urinary Aldosterone Level and Random Urinary Aldosterone-to-Creatinine Ratio in the Diagnosis of Primary Aldosteronism

BACKGROUND: Historically, urinary aldosterone level measurement was a commonly employed confirmatory test to detect primary aldosteronism (PA). However, 24-h urine collection is inconvenient and cumbersome. We hypothesized that random urinary aldosterone measurements with correction for creatinine c...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Che-Hsiung, Yang, Ya-Wen, Hu, Ya-Hui, Tsai, Yao-Chou, Kuo, Ko-Lin, Lin, Yen-Hung, Hung, Szu-Chun, Wu, Vin-Cent, Wu, Kwan-Dun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3696056/
https://www.ncbi.nlm.nih.gov/pubmed/23840695
http://dx.doi.org/10.1371/journal.pone.0067417
Descripción
Sumario:BACKGROUND: Historically, urinary aldosterone level measurement was a commonly employed confirmatory test to detect primary aldosteronism (PA). However, 24-h urine collection is inconvenient and cumbersome. We hypothesized that random urinary aldosterone measurements with correction for creatinine concentration might be comparable to 24-h urinary aldosterone levels (Uald-24 h) in the diagnosis of PA. METHODS: The non-concurrent prospective study was conducted between June 2006 and March 2008 in patients admitted for confirmation of aldosteronism by salt loading test. A 24-h urine sample, which was collected during hospitalization on the day before saline infusion testing after restoration of serum hypokalemia, was collected from all subjects. Moreover, participants were asked to collect a first bladder voiding random urine sample during clinic visits. Uald-24 h and the random urinary aldosterone-to-creatinine ratio (UACR) were calculated accordingly. RESULTS: A total of 102 PA patients (71 patients diagnosed of aldosterone-producing adenoma, 31 with idiopathic hyperaldosteronism) and 65 patients with EH were enrolled. The receiver operating characteristic curve showed comparable areas under the curves of UACR and Uald-24 h. The Bland-Altman plot showed mean bias but no obvious heteroscedasticity between the two tests. When using random UACR >3.0 ng/mg creatinine as the cutoff value, we obtained a specificity of 90.6% to confirm PA from essential hypertension. CONCLUSIONS: Our study reinforce that the diagnostic accuracy of random UACR was comparable to that of Uald-24 h in PA patients. With the quickness and simplicity of the UACR method and its equivalence to Uald-24 h, this assay could be a good alternative diagnostic tool for PA confirmation.