Perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tube

BACKGROUND: Perfusion index (PI) is a non-invasive numerical value of peripheral perfusion obtained from a pulse oximeter. In this study, we evaluated the efficacy of PI for detecting haemodynamic stress responses to insertion of i-gel, laryngeal mask airway (LMA) and endotracheal tube and compare,...

Descripción completa

Detalles Bibliográficos
Autores principales: Atef, Hosam M, Fattah, Salah Abd, Gaffer, Mohammed Emad Abd, Al Rahman, Ahamed Abd
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3696263/
https://www.ncbi.nlm.nih.gov/pubmed/23825815
http://dx.doi.org/10.4103/0019-5049.111843
Descripción
Sumario:BACKGROUND: Perfusion index (PI) is a non-invasive numerical value of peripheral perfusion obtained from a pulse oximeter. In this study, we evaluated the efficacy of PI for detecting haemodynamic stress responses to insertion of i-gel, laryngeal mask airway (LMA) and endotracheal tube and compare, its reliability with the conventional haemodynamic criteria in adults during general anaesthesia. METHODS: Sixty patients scheduled for elective general surgery under general anaesthesia were randomised to three groups. (i-gel, LMA and ET groups (n=20/group). Heart rate (HR) (positive if ≥10 bpm), systolic blood pressure (SBP), diastolic blood pressure (DBP) (positive if ≥15 mm Hg) and PI (positive if ≤10%) were monitored for 5 min after insertion. Main outcome measures: SBP, DBP, HR and PI were measured before induction of anaesthesia and before and after insertion of the airway device. RESULTS: Insertion of airway devices produced significant increases in HR, SBP and DBP in LMA and ET groups. Moreover, PI was decreased significantly by 40%, 100% and 100% in the three groups. Using the PI criterion, the sensitivity was 100% (CI 82.4-100.0%). Regarding the SBP and DBP criterions, the sensitivity was 44.4% (CI 24.6-66.3%), 55.6% (CI 33.7-75.4%) respectively. Also, significant change in the mean PI over time (from pre-insertion value to the 1(st) min, 3(rd) min, until the 4(th) min after insertion without regard the device type), (P<0.001). CONCLUSION: PI is a reliable and easier alternative to conventional haemodynamic criteria for detection of stress response to insertion of i-gel, LMA and ET during propofol fentanyl isoflurane anaesthesia in adult patients.