BACKGROUND: Perfusion index (PI) is a non-invasive numerical value of peripheral perfusion obtained from a pulse oximeter. In this study, we evaluated the efficacy of PI for detecting haemodynamic stress responses to insertion of i-gel, laryngeal mask airway (LMA) and endotracheal tube and compare,...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3696263/ https://www.ncbi.nlm.nih.gov/pubmed/23825815 http://dx.doi.org/10.4103/0019-5049.111843 |
_version_ | 1782476311300669440 |
---|---|
author | Atef, Hosam M Fattah, Salah Abd Gaffer, Mohammed Emad Abd Al Rahman, Ahamed Abd |
author_facet | Atef, Hosam M Fattah, Salah Abd Gaffer, Mohammed Emad Abd Al Rahman, Ahamed Abd |
author_sort | Atef, Hosam M |
collection | PubMed |
description | BACKGROUND: Perfusion index (PI) is a non-invasive numerical value of peripheral perfusion obtained from a pulse oximeter. In this study, we evaluated the efficacy of PI for detecting haemodynamic stress responses to insertion of i-gel, laryngeal mask airway (LMA) and endotracheal tube and compare, its reliability with the conventional haemodynamic criteria in adults during general anaesthesia. METHODS: Sixty patients scheduled for elective general surgery under general anaesthesia were randomised to three groups. (i-gel, LMA and ET groups (n=20/group). Heart rate (HR) (positive if ≥10 bpm), systolic blood pressure (SBP), diastolic blood pressure (DBP) (positive if ≥15 mm Hg) and PI (positive if ≤10%) were monitored for 5 min after insertion. Main outcome measures: SBP, DBP, HR and PI were measured before induction of anaesthesia and before and after insertion of the airway device. RESULTS: Insertion of airway devices produced significant increases in HR, SBP and DBP in LMA and ET groups. Moreover, PI was decreased significantly by 40%, 100% and 100% in the three groups. Using the PI criterion, the sensitivity was 100% (CI 82.4-100.0%). Regarding the SBP and DBP criterions, the sensitivity was 44.4% (CI 24.6-66.3%), 55.6% (CI 33.7-75.4%) respectively. Also, significant change in the mean PI over time (from pre-insertion value to the 1(st) min, 3(rd) min, until the 4(th) min after insertion without regard the device type), (P<0.001). CONCLUSION: PI is a reliable and easier alternative to conventional haemodynamic criteria for detection of stress response to insertion of i-gel, LMA and ET during propofol fentanyl isoflurane anaesthesia in adult patients. |
format | Online Article Text |
id | pubmed-3696263 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-36962632013-07-03 Perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tube Atef, Hosam M Fattah, Salah Abd Gaffer, Mohammed Emad Abd Al Rahman, Ahamed Abd Indian J Anaesth Clinical Investigation BACKGROUND: Perfusion index (PI) is a non-invasive numerical value of peripheral perfusion obtained from a pulse oximeter. In this study, we evaluated the efficacy of PI for detecting haemodynamic stress responses to insertion of i-gel, laryngeal mask airway (LMA) and endotracheal tube and compare, its reliability with the conventional haemodynamic criteria in adults during general anaesthesia. METHODS: Sixty patients scheduled for elective general surgery under general anaesthesia were randomised to three groups. (i-gel, LMA and ET groups (n=20/group). Heart rate (HR) (positive if ≥10 bpm), systolic blood pressure (SBP), diastolic blood pressure (DBP) (positive if ≥15 mm Hg) and PI (positive if ≤10%) were monitored for 5 min after insertion. Main outcome measures: SBP, DBP, HR and PI were measured before induction of anaesthesia and before and after insertion of the airway device. RESULTS: Insertion of airway devices produced significant increases in HR, SBP and DBP in LMA and ET groups. Moreover, PI was decreased significantly by 40%, 100% and 100% in the three groups. Using the PI criterion, the sensitivity was 100% (CI 82.4-100.0%). Regarding the SBP and DBP criterions, the sensitivity was 44.4% (CI 24.6-66.3%), 55.6% (CI 33.7-75.4%) respectively. Also, significant change in the mean PI over time (from pre-insertion value to the 1(st) min, 3(rd) min, until the 4(th) min after insertion without regard the device type), (P<0.001). CONCLUSION: PI is a reliable and easier alternative to conventional haemodynamic criteria for detection of stress response to insertion of i-gel, LMA and ET during propofol fentanyl isoflurane anaesthesia in adult patients. Medknow Publications & Media Pvt Ltd 2013 /pmc/articles/PMC3696263/ /pubmed/23825815 http://dx.doi.org/10.4103/0019-5049.111843 Text en Copyright: © Indian Journal of Anaesthesia http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Investigation Atef, Hosam M Fattah, Salah Abd Gaffer, Mohammed Emad Abd Al Rahman, Ahamed Abd Perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tube |
title | Perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tube |
title_full | Perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tube |
title_fullStr | Perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tube |
title_full_unstemmed | Perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tube |
title_short | Perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tube |
title_sort | perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tube |
topic | Clinical Investigation |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3696263/ https://www.ncbi.nlm.nih.gov/pubmed/23825815 http://dx.doi.org/10.4103/0019-5049.111843 |
work_keys_str_mv | AT atefhosamm perfusionindexversusnoninvasivehemodynamicparametersduringinsertionofigelclassiclaryngealmaskairwayandendotrachealtube AT fattahsalahabd perfusionindexversusnoninvasivehemodynamicparametersduringinsertionofigelclassiclaryngealmaskairwayandendotrachealtube AT gaffermohammedemadabd perfusionindexversusnoninvasivehemodynamicparametersduringinsertionofigelclassiclaryngealmaskairwayandendotrachealtube AT alrahmanahamedabd perfusionindexversusnoninvasivehemodynamicparametersduringinsertionofigelclassiclaryngealmaskairwayandendotrachealtube |