Cargando…

Saliva sampling in global clinical studies: the impact of low sampling volume on performance of DNA in downstream genotyping experiments

BACKGROUND: The collection of viable DNA samples is an essential element of any genetics research programme. Biological samples for DNA purification are now routinely collected in many studies with a variety of sampling methods available. Initial observation in this study suggested a reduced genotyp...

Descripción completa

Detalles Bibliográficos
Autores principales: Pulford, David J, Mosteller, Michael, Briley, J David, Johansson, Kelley W, Nelsen, Anita J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3698156/
https://www.ncbi.nlm.nih.gov/pubmed/23759220
http://dx.doi.org/10.1186/1755-8794-6-20
_version_ 1782275254281830400
author Pulford, David J
Mosteller, Michael
Briley, J David
Johansson, Kelley W
Nelsen, Anita J
author_facet Pulford, David J
Mosteller, Michael
Briley, J David
Johansson, Kelley W
Nelsen, Anita J
author_sort Pulford, David J
collection PubMed
description BACKGROUND: The collection of viable DNA samples is an essential element of any genetics research programme. Biological samples for DNA purification are now routinely collected in many studies with a variety of sampling methods available. Initial observation in this study suggested a reduced genotyping success rate of some saliva derived DNA samples when compared to blood derived DNA samples prompting further investigation. METHODS: Genotyping success rate was investigated to assess the suitability of using saliva samples in future safety and efficacy pharmacogenetics experiments. The Oragene® OG-300 DNA Self-Collection kit was used to collect and extract DNA from saliva from 1468 subjects enrolled in global clinical studies. Statistical analysis evaluated the impact of saliva sample volume of collection on the quality, yield, concentration and performance of saliva DNA in genotyping assays. RESULTS: Across 13 global clinical studies that utilized the Oragene® OG-300 DNA Self-Collection kit there was variability in the volume of saliva sample collection with ~31% of participants providing 0.5 mL of saliva, rather than the recommended 2 mL. While the majority of saliva DNA samples provided high quality genotype data, collection of 0.5 mL volumes of saliva contributed to DNA samples being significantly less likely to pass genotyping quality control standards. Assessment of DNA sample characteristics that may influence genotyping outcomes indicated that saliva sample volume, DNA purity and turbidity were independently associated with sample genotype pass rate, but that saliva collection volume had the greatest effect. CONCLUSION: When employing saliva sampling to obtain DNA, it is important to encourage all study participants to provide sufficient sample to minimize potential loss of data in downstream genotyping experiments.
format Online
Article
Text
id pubmed-3698156
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-36981562013-07-02 Saliva sampling in global clinical studies: the impact of low sampling volume on performance of DNA in downstream genotyping experiments Pulford, David J Mosteller, Michael Briley, J David Johansson, Kelley W Nelsen, Anita J BMC Med Genomics Research Article BACKGROUND: The collection of viable DNA samples is an essential element of any genetics research programme. Biological samples for DNA purification are now routinely collected in many studies with a variety of sampling methods available. Initial observation in this study suggested a reduced genotyping success rate of some saliva derived DNA samples when compared to blood derived DNA samples prompting further investigation. METHODS: Genotyping success rate was investigated to assess the suitability of using saliva samples in future safety and efficacy pharmacogenetics experiments. The Oragene® OG-300 DNA Self-Collection kit was used to collect and extract DNA from saliva from 1468 subjects enrolled in global clinical studies. Statistical analysis evaluated the impact of saliva sample volume of collection on the quality, yield, concentration and performance of saliva DNA in genotyping assays. RESULTS: Across 13 global clinical studies that utilized the Oragene® OG-300 DNA Self-Collection kit there was variability in the volume of saliva sample collection with ~31% of participants providing 0.5 mL of saliva, rather than the recommended 2 mL. While the majority of saliva DNA samples provided high quality genotype data, collection of 0.5 mL volumes of saliva contributed to DNA samples being significantly less likely to pass genotyping quality control standards. Assessment of DNA sample characteristics that may influence genotyping outcomes indicated that saliva sample volume, DNA purity and turbidity were independently associated with sample genotype pass rate, but that saliva collection volume had the greatest effect. CONCLUSION: When employing saliva sampling to obtain DNA, it is important to encourage all study participants to provide sufficient sample to minimize potential loss of data in downstream genotyping experiments. BioMed Central 2013-06-10 /pmc/articles/PMC3698156/ /pubmed/23759220 http://dx.doi.org/10.1186/1755-8794-6-20 Text en Copyright © 2013 Pulford et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Pulford, David J
Mosteller, Michael
Briley, J David
Johansson, Kelley W
Nelsen, Anita J
Saliva sampling in global clinical studies: the impact of low sampling volume on performance of DNA in downstream genotyping experiments
title Saliva sampling in global clinical studies: the impact of low sampling volume on performance of DNA in downstream genotyping experiments
title_full Saliva sampling in global clinical studies: the impact of low sampling volume on performance of DNA in downstream genotyping experiments
title_fullStr Saliva sampling in global clinical studies: the impact of low sampling volume on performance of DNA in downstream genotyping experiments
title_full_unstemmed Saliva sampling in global clinical studies: the impact of low sampling volume on performance of DNA in downstream genotyping experiments
title_short Saliva sampling in global clinical studies: the impact of low sampling volume on performance of DNA in downstream genotyping experiments
title_sort saliva sampling in global clinical studies: the impact of low sampling volume on performance of dna in downstream genotyping experiments
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3698156/
https://www.ncbi.nlm.nih.gov/pubmed/23759220
http://dx.doi.org/10.1186/1755-8794-6-20
work_keys_str_mv AT pulforddavidj salivasamplinginglobalclinicalstudiestheimpactoflowsamplingvolumeonperformanceofdnaindownstreamgenotypingexperiments
AT mostellermichael salivasamplinginglobalclinicalstudiestheimpactoflowsamplingvolumeonperformanceofdnaindownstreamgenotypingexperiments
AT brileyjdavid salivasamplinginglobalclinicalstudiestheimpactoflowsamplingvolumeonperformanceofdnaindownstreamgenotypingexperiments
AT johanssonkelleyw salivasamplinginglobalclinicalstudiestheimpactoflowsamplingvolumeonperformanceofdnaindownstreamgenotypingexperiments
AT nelsenanitaj salivasamplinginglobalclinicalstudiestheimpactoflowsamplingvolumeonperformanceofdnaindownstreamgenotypingexperiments