Objective assessment of skin tightening in Asians using a water-filtered near-infrared (1,000–1,800 nm) device with contact-cooling and freezer-stored gel

BACKGROUND: Near-infrared has been shown to penetrate deeper than optical light sources independent of skin color, allowing safer treatment for the Asian skin type. Many studies have indicated the efficacy of various types of devices, but have not included a sufficiently objective evaluation. In thi...

Descripción completa

Detalles Bibliográficos
Autores principales: Tanaka, Yohei, Tsunemi, Yuichiro, Kawashima, Makoto, Tatewaki, Naoto, Nishida, Hiroshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3699058/
https://www.ncbi.nlm.nih.gov/pubmed/23837000
http://dx.doi.org/10.2147/CCID.S47299
_version_ 1782275350369140736
author Tanaka, Yohei
Tsunemi, Yuichiro
Kawashima, Makoto
Tatewaki, Naoto
Nishida, Hiroshi
author_facet Tanaka, Yohei
Tsunemi, Yuichiro
Kawashima, Makoto
Tatewaki, Naoto
Nishida, Hiroshi
author_sort Tanaka, Yohei
collection PubMed
description BACKGROUND: Near-infrared has been shown to penetrate deeper than optical light sources independent of skin color, allowing safer treatment for the Asian skin type. Many studies have indicated the efficacy of various types of devices, but have not included a sufficiently objective evaluation. In this study, we used three-dimensional imaging for objective evaluation of facial skin tightening using a water-filtered near-infrared device. METHODS: Twenty Japanese patients were treated with the water-filtered near-infrared (1,000–1,800 nm) device using a contact-cooling and nonfreezing gel stored in a freezer. Three-dimensional imaging was performed, and quantitative volume measurements were taken to evaluate the change in post-treatment volume. The patients then provided their subjective assessments. RESULTS: Objective assessments of the treated cheek volume evaluated by a three-dimensional color schematic representation with quantitative volume measurements showed significant improvement 3 months after treatment. The mean volume reduction at the last post-treatment visit was 2.554 ± 0.999 mL. The post-treatment volume was significantly reduced compared with the pretreatment volume in all patients (P < 0.0001). Eighty-five percent of patients reported satisfaction with the improvement of skin laxity, and 80% of patients reported satisfaction with improvement of rhytids, such as the nasolabial folds. Side effects, such as epidermal burns and scar formation, were not observed throughout the study. CONCLUSION: The advantages of this water-filtered near-infrared treatment are its high efficacy for skin tightening, associated with a minimal level of discomfort and minimal side effects. Together, these characteristics facilitate our ability to administer repeated treatments and provide alternative or adjunctive treatment for patients, with improved results. This study provides a qualitative and quantitative volumetric assessment, establishing the ability of this technology to reduce volume through noninvasive skin tightening.
format Online
Article
Text
id pubmed-3699058
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-36990582013-07-08 Objective assessment of skin tightening in Asians using a water-filtered near-infrared (1,000–1,800 nm) device with contact-cooling and freezer-stored gel Tanaka, Yohei Tsunemi, Yuichiro Kawashima, Makoto Tatewaki, Naoto Nishida, Hiroshi Clin Cosmet Investig Dermatol Original Research BACKGROUND: Near-infrared has been shown to penetrate deeper than optical light sources independent of skin color, allowing safer treatment for the Asian skin type. Many studies have indicated the efficacy of various types of devices, but have not included a sufficiently objective evaluation. In this study, we used three-dimensional imaging for objective evaluation of facial skin tightening using a water-filtered near-infrared device. METHODS: Twenty Japanese patients were treated with the water-filtered near-infrared (1,000–1,800 nm) device using a contact-cooling and nonfreezing gel stored in a freezer. Three-dimensional imaging was performed, and quantitative volume measurements were taken to evaluate the change in post-treatment volume. The patients then provided their subjective assessments. RESULTS: Objective assessments of the treated cheek volume evaluated by a three-dimensional color schematic representation with quantitative volume measurements showed significant improvement 3 months after treatment. The mean volume reduction at the last post-treatment visit was 2.554 ± 0.999 mL. The post-treatment volume was significantly reduced compared with the pretreatment volume in all patients (P < 0.0001). Eighty-five percent of patients reported satisfaction with the improvement of skin laxity, and 80% of patients reported satisfaction with improvement of rhytids, such as the nasolabial folds. Side effects, such as epidermal burns and scar formation, were not observed throughout the study. CONCLUSION: The advantages of this water-filtered near-infrared treatment are its high efficacy for skin tightening, associated with a minimal level of discomfort and minimal side effects. Together, these characteristics facilitate our ability to administer repeated treatments and provide alternative or adjunctive treatment for patients, with improved results. This study provides a qualitative and quantitative volumetric assessment, establishing the ability of this technology to reduce volume through noninvasive skin tightening. Dove Medical Press 2013-06-26 /pmc/articles/PMC3699058/ /pubmed/23837000 http://dx.doi.org/10.2147/CCID.S47299 Text en © 2013 Tanaka et al, publisher and licensee Dove Medical Press Ltd This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited.
spellingShingle Original Research
Tanaka, Yohei
Tsunemi, Yuichiro
Kawashima, Makoto
Tatewaki, Naoto
Nishida, Hiroshi
Objective assessment of skin tightening in Asians using a water-filtered near-infrared (1,000–1,800 nm) device with contact-cooling and freezer-stored gel
title Objective assessment of skin tightening in Asians using a water-filtered near-infrared (1,000–1,800 nm) device with contact-cooling and freezer-stored gel
title_full Objective assessment of skin tightening in Asians using a water-filtered near-infrared (1,000–1,800 nm) device with contact-cooling and freezer-stored gel
title_fullStr Objective assessment of skin tightening in Asians using a water-filtered near-infrared (1,000–1,800 nm) device with contact-cooling and freezer-stored gel
title_full_unstemmed Objective assessment of skin tightening in Asians using a water-filtered near-infrared (1,000–1,800 nm) device with contact-cooling and freezer-stored gel
title_short Objective assessment of skin tightening in Asians using a water-filtered near-infrared (1,000–1,800 nm) device with contact-cooling and freezer-stored gel
title_sort objective assessment of skin tightening in asians using a water-filtered near-infrared (1,000–1,800 nm) device with contact-cooling and freezer-stored gel
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3699058/
https://www.ncbi.nlm.nih.gov/pubmed/23837000
http://dx.doi.org/10.2147/CCID.S47299
work_keys_str_mv AT tanakayohei objectiveassessmentofskintighteninginasiansusingawaterfilterednearinfrared10001800nmdevicewithcontactcoolingandfreezerstoredgel
AT tsunemiyuichiro objectiveassessmentofskintighteninginasiansusingawaterfilterednearinfrared10001800nmdevicewithcontactcoolingandfreezerstoredgel
AT kawashimamakoto objectiveassessmentofskintighteninginasiansusingawaterfilterednearinfrared10001800nmdevicewithcontactcoolingandfreezerstoredgel
AT tatewakinaoto objectiveassessmentofskintighteninginasiansusingawaterfilterednearinfrared10001800nmdevicewithcontactcoolingandfreezerstoredgel
AT nishidahiroshi objectiveassessmentofskintighteninginasiansusingawaterfilterednearinfrared10001800nmdevicewithcontactcoolingandfreezerstoredgel