Cargando…
A Novel Method of Estimating Dose Responses for Polymer Gels Using Texture Analysis of Scanning Electron Microscopy Images
Polymer gels are regarded as a potential dosimeter for independent validation of absorbed doses in clinical radiotherapy. Several imaging modalities have been used to convert radiation-induced polymerization to absorbed doses from a macro-scale viewpoint. This study developed a novel dose conversion...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3699568/ https://www.ncbi.nlm.nih.gov/pubmed/23843998 http://dx.doi.org/10.1371/journal.pone.0067281 |
_version_ | 1782275413375975424 |
---|---|
author | Shih, Cheng-Ting Hsu, Jui-Ting Han, Rou-Ping Hsieh, Bor-Tsung Chang, Shu-Jun Wu, Jay |
author_facet | Shih, Cheng-Ting Hsu, Jui-Ting Han, Rou-Ping Hsieh, Bor-Tsung Chang, Shu-Jun Wu, Jay |
author_sort | Shih, Cheng-Ting |
collection | PubMed |
description | Polymer gels are regarded as a potential dosimeter for independent validation of absorbed doses in clinical radiotherapy. Several imaging modalities have been used to convert radiation-induced polymerization to absorbed doses from a macro-scale viewpoint. This study developed a novel dose conversion mechanism by texture analysis of scanning electron microscopy (SEM) images. The modified N-isopropyl-acrylamide (NIPAM) gels were prepared under normoxic conditions, and were administered radiation doses from 5 to 20 Gy. After freeze drying, the gel samples were sliced for SEM scanning with 50×, 500×, and 3500× magnifications. Four texture indices were calculated based on the gray level co-occurrence matrix (GLCM). The results showed that entropy and homogeneity were more suitable than contrast and energy as dose indices for higher linearity and sensitivity of the dose response curves. After parameter optimization, an R (2) value of 0.993 can be achieved for homogeneity using 500× magnified SEM images with 27 pixel offsets and no outlier exclusion. For dose verification, the percentage errors between the prescribed dose and the measured dose for 5, 10, 15, and 20 Gy were −7.60%, 5.80%, 2.53%, and −0.95%, respectively. We conclude that texture analysis can be applied to the SEM images of gel dosimeters to accurately convert micro-scale structural features to absorbed doses. The proposed method may extend the feasibility of applying gel dosimeters in the fields of diagnostic radiology and radiation protection. |
format | Online Article Text |
id | pubmed-3699568 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-36995682013-07-10 A Novel Method of Estimating Dose Responses for Polymer Gels Using Texture Analysis of Scanning Electron Microscopy Images Shih, Cheng-Ting Hsu, Jui-Ting Han, Rou-Ping Hsieh, Bor-Tsung Chang, Shu-Jun Wu, Jay PLoS One Research Article Polymer gels are regarded as a potential dosimeter for independent validation of absorbed doses in clinical radiotherapy. Several imaging modalities have been used to convert radiation-induced polymerization to absorbed doses from a macro-scale viewpoint. This study developed a novel dose conversion mechanism by texture analysis of scanning electron microscopy (SEM) images. The modified N-isopropyl-acrylamide (NIPAM) gels were prepared under normoxic conditions, and were administered radiation doses from 5 to 20 Gy. After freeze drying, the gel samples were sliced for SEM scanning with 50×, 500×, and 3500× magnifications. Four texture indices were calculated based on the gray level co-occurrence matrix (GLCM). The results showed that entropy and homogeneity were more suitable than contrast and energy as dose indices for higher linearity and sensitivity of the dose response curves. After parameter optimization, an R (2) value of 0.993 can be achieved for homogeneity using 500× magnified SEM images with 27 pixel offsets and no outlier exclusion. For dose verification, the percentage errors between the prescribed dose and the measured dose for 5, 10, 15, and 20 Gy were −7.60%, 5.80%, 2.53%, and −0.95%, respectively. We conclude that texture analysis can be applied to the SEM images of gel dosimeters to accurately convert micro-scale structural features to absorbed doses. The proposed method may extend the feasibility of applying gel dosimeters in the fields of diagnostic radiology and radiation protection. Public Library of Science 2013-07-02 /pmc/articles/PMC3699568/ /pubmed/23843998 http://dx.doi.org/10.1371/journal.pone.0067281 Text en © 2013 Shih et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Shih, Cheng-Ting Hsu, Jui-Ting Han, Rou-Ping Hsieh, Bor-Tsung Chang, Shu-Jun Wu, Jay A Novel Method of Estimating Dose Responses for Polymer Gels Using Texture Analysis of Scanning Electron Microscopy Images |
title | A Novel Method of Estimating Dose Responses for Polymer Gels Using Texture Analysis of Scanning Electron Microscopy Images |
title_full | A Novel Method of Estimating Dose Responses for Polymer Gels Using Texture Analysis of Scanning Electron Microscopy Images |
title_fullStr | A Novel Method of Estimating Dose Responses for Polymer Gels Using Texture Analysis of Scanning Electron Microscopy Images |
title_full_unstemmed | A Novel Method of Estimating Dose Responses for Polymer Gels Using Texture Analysis of Scanning Electron Microscopy Images |
title_short | A Novel Method of Estimating Dose Responses for Polymer Gels Using Texture Analysis of Scanning Electron Microscopy Images |
title_sort | novel method of estimating dose responses for polymer gels using texture analysis of scanning electron microscopy images |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3699568/ https://www.ncbi.nlm.nih.gov/pubmed/23843998 http://dx.doi.org/10.1371/journal.pone.0067281 |
work_keys_str_mv | AT shihchengting anovelmethodofestimatingdoseresponsesforpolymergelsusingtextureanalysisofscanningelectronmicroscopyimages AT hsujuiting anovelmethodofestimatingdoseresponsesforpolymergelsusingtextureanalysisofscanningelectronmicroscopyimages AT hanrouping anovelmethodofestimatingdoseresponsesforpolymergelsusingtextureanalysisofscanningelectronmicroscopyimages AT hsiehbortsung anovelmethodofestimatingdoseresponsesforpolymergelsusingtextureanalysisofscanningelectronmicroscopyimages AT changshujun anovelmethodofestimatingdoseresponsesforpolymergelsusingtextureanalysisofscanningelectronmicroscopyimages AT wujay anovelmethodofestimatingdoseresponsesforpolymergelsusingtextureanalysisofscanningelectronmicroscopyimages AT shihchengting novelmethodofestimatingdoseresponsesforpolymergelsusingtextureanalysisofscanningelectronmicroscopyimages AT hsujuiting novelmethodofestimatingdoseresponsesforpolymergelsusingtextureanalysisofscanningelectronmicroscopyimages AT hanrouping novelmethodofestimatingdoseresponsesforpolymergelsusingtextureanalysisofscanningelectronmicroscopyimages AT hsiehbortsung novelmethodofestimatingdoseresponsesforpolymergelsusingtextureanalysisofscanningelectronmicroscopyimages AT changshujun novelmethodofestimatingdoseresponsesforpolymergelsusingtextureanalysisofscanningelectronmicroscopyimages AT wujay novelmethodofestimatingdoseresponsesforpolymergelsusingtextureanalysisofscanningelectronmicroscopyimages |