Cargando…
Sodium Concentration Measurement during Hemodialysis through Ion-Exchange Resin and Conductivity Measure Approach: In Vitro Experiments
Sodium measurement during hemodialysis treatment is important to preserve the patient from clinical events related to hypo- or hyper-natremia Usually, sodium measurement is performed through laboratory equipment which is typically expensive, and requires manual intervention. We propose a new method,...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3699667/ https://www.ncbi.nlm.nih.gov/pubmed/23844253 http://dx.doi.org/10.1371/journal.pone.0069227 |
_version_ | 1782275435901485056 |
---|---|
author | Tura, Andrea Sbrignadello, Stefano Mambelli, Emanuele Ravazzani, Paolo Santoro, Antonio Pacini, Giovanni |
author_facet | Tura, Andrea Sbrignadello, Stefano Mambelli, Emanuele Ravazzani, Paolo Santoro, Antonio Pacini, Giovanni |
author_sort | Tura, Andrea |
collection | PubMed |
description | Sodium measurement during hemodialysis treatment is important to preserve the patient from clinical events related to hypo- or hyper-natremia Usually, sodium measurement is performed through laboratory equipment which is typically expensive, and requires manual intervention. We propose a new method, based on conductivity measurement after treatment of dialysate solution through ion-exchange resin. To test this method, we performed in vitro experiments. We prepared 40 ml sodium chloride (NaCl) samples at 280, 140, 70, 35, 17.5, 8.75, 4.375 mEq/l, and some “mixed samples”, i.e., with added potassium chloride (KCl) at different concentrations (4.375-17.5 mEq/l), to simulate the confounding factors in a conductivity-based sodium measurement. We measured the conductivity of all samples. Afterwards, each sample was treated for 1 min with 1 g of Dowex G-26 resin, and conductivity was measured again. On average, the difference in the conductivity between mixed samples and corresponding pure NaCl samples (at the same NaCl concentration) was 20.9%. After treatment with the exchange resin, it was 14.7%, i.e., 42% lower. Similar experiments were performed with calcium chloride and magnesium chloride as confounding factors, with similar results. We also performed some experiments on actual dialysate solution during hemodialysis sessions in 15 patients, and found that the correlation between conductivity measures and sodium concentration improved after resin treatment (R=0.839 before treatment, R=0.924 after treatment, P<0.0001). We conclude that ion-exchange resin treatment coupled with conductivity measures may improve the measurement of sodium compared to conductivity measures alone, and may become a possible simple approach for continuous and automatic sodium measurement during hemodialysis. |
format | Online Article Text |
id | pubmed-3699667 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-36996672013-07-10 Sodium Concentration Measurement during Hemodialysis through Ion-Exchange Resin and Conductivity Measure Approach: In Vitro Experiments Tura, Andrea Sbrignadello, Stefano Mambelli, Emanuele Ravazzani, Paolo Santoro, Antonio Pacini, Giovanni PLoS One Research Article Sodium measurement during hemodialysis treatment is important to preserve the patient from clinical events related to hypo- or hyper-natremia Usually, sodium measurement is performed through laboratory equipment which is typically expensive, and requires manual intervention. We propose a new method, based on conductivity measurement after treatment of dialysate solution through ion-exchange resin. To test this method, we performed in vitro experiments. We prepared 40 ml sodium chloride (NaCl) samples at 280, 140, 70, 35, 17.5, 8.75, 4.375 mEq/l, and some “mixed samples”, i.e., with added potassium chloride (KCl) at different concentrations (4.375-17.5 mEq/l), to simulate the confounding factors in a conductivity-based sodium measurement. We measured the conductivity of all samples. Afterwards, each sample was treated for 1 min with 1 g of Dowex G-26 resin, and conductivity was measured again. On average, the difference in the conductivity between mixed samples and corresponding pure NaCl samples (at the same NaCl concentration) was 20.9%. After treatment with the exchange resin, it was 14.7%, i.e., 42% lower. Similar experiments were performed with calcium chloride and magnesium chloride as confounding factors, with similar results. We also performed some experiments on actual dialysate solution during hemodialysis sessions in 15 patients, and found that the correlation between conductivity measures and sodium concentration improved after resin treatment (R=0.839 before treatment, R=0.924 after treatment, P<0.0001). We conclude that ion-exchange resin treatment coupled with conductivity measures may improve the measurement of sodium compared to conductivity measures alone, and may become a possible simple approach for continuous and automatic sodium measurement during hemodialysis. Public Library of Science 2013-07-02 /pmc/articles/PMC3699667/ /pubmed/23844253 http://dx.doi.org/10.1371/journal.pone.0069227 Text en © 2013 Tura et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Tura, Andrea Sbrignadello, Stefano Mambelli, Emanuele Ravazzani, Paolo Santoro, Antonio Pacini, Giovanni Sodium Concentration Measurement during Hemodialysis through Ion-Exchange Resin and Conductivity Measure Approach: In Vitro Experiments |
title | Sodium Concentration Measurement during Hemodialysis through Ion-Exchange Resin and Conductivity Measure Approach: In Vitro Experiments |
title_full | Sodium Concentration Measurement during Hemodialysis through Ion-Exchange Resin and Conductivity Measure Approach: In Vitro Experiments |
title_fullStr | Sodium Concentration Measurement during Hemodialysis through Ion-Exchange Resin and Conductivity Measure Approach: In Vitro Experiments |
title_full_unstemmed | Sodium Concentration Measurement during Hemodialysis through Ion-Exchange Resin and Conductivity Measure Approach: In Vitro Experiments |
title_short | Sodium Concentration Measurement during Hemodialysis through Ion-Exchange Resin and Conductivity Measure Approach: In Vitro Experiments |
title_sort | sodium concentration measurement during hemodialysis through ion-exchange resin and conductivity measure approach: in vitro experiments |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3699667/ https://www.ncbi.nlm.nih.gov/pubmed/23844253 http://dx.doi.org/10.1371/journal.pone.0069227 |
work_keys_str_mv | AT turaandrea sodiumconcentrationmeasurementduringhemodialysisthroughionexchangeresinandconductivitymeasureapproachinvitroexperiments AT sbrignadellostefano sodiumconcentrationmeasurementduringhemodialysisthroughionexchangeresinandconductivitymeasureapproachinvitroexperiments AT mambelliemanuele sodiumconcentrationmeasurementduringhemodialysisthroughionexchangeresinandconductivitymeasureapproachinvitroexperiments AT ravazzanipaolo sodiumconcentrationmeasurementduringhemodialysisthroughionexchangeresinandconductivitymeasureapproachinvitroexperiments AT santoroantonio sodiumconcentrationmeasurementduringhemodialysisthroughionexchangeresinandconductivitymeasureapproachinvitroexperiments AT pacinigiovanni sodiumconcentrationmeasurementduringhemodialysisthroughionexchangeresinandconductivitymeasureapproachinvitroexperiments |