Cargando…

Sodium Concentration Measurement during Hemodialysis through Ion-Exchange Resin and Conductivity Measure Approach: In Vitro Experiments

Sodium measurement during hemodialysis treatment is important to preserve the patient from clinical events related to hypo- or hyper-natremia Usually, sodium measurement is performed through laboratory equipment which is typically expensive, and requires manual intervention. We propose a new method,...

Descripción completa

Detalles Bibliográficos
Autores principales: Tura, Andrea, Sbrignadello, Stefano, Mambelli, Emanuele, Ravazzani, Paolo, Santoro, Antonio, Pacini, Giovanni
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3699667/
https://www.ncbi.nlm.nih.gov/pubmed/23844253
http://dx.doi.org/10.1371/journal.pone.0069227
_version_ 1782275435901485056
author Tura, Andrea
Sbrignadello, Stefano
Mambelli, Emanuele
Ravazzani, Paolo
Santoro, Antonio
Pacini, Giovanni
author_facet Tura, Andrea
Sbrignadello, Stefano
Mambelli, Emanuele
Ravazzani, Paolo
Santoro, Antonio
Pacini, Giovanni
author_sort Tura, Andrea
collection PubMed
description Sodium measurement during hemodialysis treatment is important to preserve the patient from clinical events related to hypo- or hyper-natremia Usually, sodium measurement is performed through laboratory equipment which is typically expensive, and requires manual intervention. We propose a new method, based on conductivity measurement after treatment of dialysate solution through ion-exchange resin. To test this method, we performed in vitro experiments. We prepared 40 ml sodium chloride (NaCl) samples at 280, 140, 70, 35, 17.5, 8.75, 4.375 mEq/l, and some “mixed samples”, i.e., with added potassium chloride (KCl) at different concentrations (4.375-17.5 mEq/l), to simulate the confounding factors in a conductivity-based sodium measurement. We measured the conductivity of all samples. Afterwards, each sample was treated for 1 min with 1 g of Dowex G-26 resin, and conductivity was measured again. On average, the difference in the conductivity between mixed samples and corresponding pure NaCl samples (at the same NaCl concentration) was 20.9%. After treatment with the exchange resin, it was 14.7%, i.e., 42% lower. Similar experiments were performed with calcium chloride and magnesium chloride as confounding factors, with similar results. We also performed some experiments on actual dialysate solution during hemodialysis sessions in 15 patients, and found that the correlation between conductivity measures and sodium concentration improved after resin treatment (R=0.839 before treatment, R=0.924 after treatment, P<0.0001). We conclude that ion-exchange resin treatment coupled with conductivity measures may improve the measurement of sodium compared to conductivity measures alone, and may become a possible simple approach for continuous and automatic sodium measurement during hemodialysis.
format Online
Article
Text
id pubmed-3699667
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-36996672013-07-10 Sodium Concentration Measurement during Hemodialysis through Ion-Exchange Resin and Conductivity Measure Approach: In Vitro Experiments Tura, Andrea Sbrignadello, Stefano Mambelli, Emanuele Ravazzani, Paolo Santoro, Antonio Pacini, Giovanni PLoS One Research Article Sodium measurement during hemodialysis treatment is important to preserve the patient from clinical events related to hypo- or hyper-natremia Usually, sodium measurement is performed through laboratory equipment which is typically expensive, and requires manual intervention. We propose a new method, based on conductivity measurement after treatment of dialysate solution through ion-exchange resin. To test this method, we performed in vitro experiments. We prepared 40 ml sodium chloride (NaCl) samples at 280, 140, 70, 35, 17.5, 8.75, 4.375 mEq/l, and some “mixed samples”, i.e., with added potassium chloride (KCl) at different concentrations (4.375-17.5 mEq/l), to simulate the confounding factors in a conductivity-based sodium measurement. We measured the conductivity of all samples. Afterwards, each sample was treated for 1 min with 1 g of Dowex G-26 resin, and conductivity was measured again. On average, the difference in the conductivity between mixed samples and corresponding pure NaCl samples (at the same NaCl concentration) was 20.9%. After treatment with the exchange resin, it was 14.7%, i.e., 42% lower. Similar experiments were performed with calcium chloride and magnesium chloride as confounding factors, with similar results. We also performed some experiments on actual dialysate solution during hemodialysis sessions in 15 patients, and found that the correlation between conductivity measures and sodium concentration improved after resin treatment (R=0.839 before treatment, R=0.924 after treatment, P<0.0001). We conclude that ion-exchange resin treatment coupled with conductivity measures may improve the measurement of sodium compared to conductivity measures alone, and may become a possible simple approach for continuous and automatic sodium measurement during hemodialysis. Public Library of Science 2013-07-02 /pmc/articles/PMC3699667/ /pubmed/23844253 http://dx.doi.org/10.1371/journal.pone.0069227 Text en © 2013 Tura et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Tura, Andrea
Sbrignadello, Stefano
Mambelli, Emanuele
Ravazzani, Paolo
Santoro, Antonio
Pacini, Giovanni
Sodium Concentration Measurement during Hemodialysis through Ion-Exchange Resin and Conductivity Measure Approach: In Vitro Experiments
title Sodium Concentration Measurement during Hemodialysis through Ion-Exchange Resin and Conductivity Measure Approach: In Vitro Experiments
title_full Sodium Concentration Measurement during Hemodialysis through Ion-Exchange Resin and Conductivity Measure Approach: In Vitro Experiments
title_fullStr Sodium Concentration Measurement during Hemodialysis through Ion-Exchange Resin and Conductivity Measure Approach: In Vitro Experiments
title_full_unstemmed Sodium Concentration Measurement during Hemodialysis through Ion-Exchange Resin and Conductivity Measure Approach: In Vitro Experiments
title_short Sodium Concentration Measurement during Hemodialysis through Ion-Exchange Resin and Conductivity Measure Approach: In Vitro Experiments
title_sort sodium concentration measurement during hemodialysis through ion-exchange resin and conductivity measure approach: in vitro experiments
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3699667/
https://www.ncbi.nlm.nih.gov/pubmed/23844253
http://dx.doi.org/10.1371/journal.pone.0069227
work_keys_str_mv AT turaandrea sodiumconcentrationmeasurementduringhemodialysisthroughionexchangeresinandconductivitymeasureapproachinvitroexperiments
AT sbrignadellostefano sodiumconcentrationmeasurementduringhemodialysisthroughionexchangeresinandconductivitymeasureapproachinvitroexperiments
AT mambelliemanuele sodiumconcentrationmeasurementduringhemodialysisthroughionexchangeresinandconductivitymeasureapproachinvitroexperiments
AT ravazzanipaolo sodiumconcentrationmeasurementduringhemodialysisthroughionexchangeresinandconductivitymeasureapproachinvitroexperiments
AT santoroantonio sodiumconcentrationmeasurementduringhemodialysisthroughionexchangeresinandconductivitymeasureapproachinvitroexperiments
AT pacinigiovanni sodiumconcentrationmeasurementduringhemodialysisthroughionexchangeresinandconductivitymeasureapproachinvitroexperiments