Simulated 50 % radiation dose reduction in coronary CT angiography using adaptive iterative dose reduction in three-dimensions (AIDR3D)

To compare the image quality of coronary CT angiography (CTA) studies between standard filtered back projection (FBP) and adaptive iterative dose reduction in three-dimensions (AIDR3D) reconstruction using CT noise additional software to simulate reduced radiation exposure. Images from 93 consecutiv...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Marcus Y., Steigner, Michael L., Leung, Steve W., Kumamaru, Kanako K., Schultz, Kurt, Mather, Richard T., Arai, Andrew E., Rybicki, Frank J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3701132/
https://www.ncbi.nlm.nih.gov/pubmed/23404384
http://dx.doi.org/10.1007/s10554-013-0190-1
_version_ 1782275598566031360
author Chen, Marcus Y.
Steigner, Michael L.
Leung, Steve W.
Kumamaru, Kanako K.
Schultz, Kurt
Mather, Richard T.
Arai, Andrew E.
Rybicki, Frank J.
author_facet Chen, Marcus Y.
Steigner, Michael L.
Leung, Steve W.
Kumamaru, Kanako K.
Schultz, Kurt
Mather, Richard T.
Arai, Andrew E.
Rybicki, Frank J.
author_sort Chen, Marcus Y.
collection PubMed
description To compare the image quality of coronary CT angiography (CTA) studies between standard filtered back projection (FBP) and adaptive iterative dose reduction in three-dimensions (AIDR3D) reconstruction using CT noise additional software to simulate reduced radiation exposure. Images from 93 consecutive clinical coronary CTA studies were processed utilizing standard FBP, FBP with 50 % simulated dose reduction (FBP50 %), and AIDR3D with simulated 50 % dose reduction (AIDR50 %). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured within 5 regions-of-interest, and image quality for each reconstruction strategy was assessed by two independent readers using a 4-point scale. Compared to FBP, the SNR measured from the AIDR50 % images was similar or higher (airway: 38.3 ± 12.7 vs. 38.5 ± 14.5, p = 0.81, fat: 5.5 ± 1.9 vs. 5.4 ± 2.0, p = 0.20, muscle: 3.2 ± 1.2 vs. 3.1 ± 1.3, p = 0.38, aorta: 22.6 ± 9.4 vs. 20.2 ± 9.7, p < 0.0001, liver: 2.7 ± 1.0 vs. 2.3 ± 1.1, p < 0.0001), while the SNR of the FBP50 % images were all lower (p values < 0.0001). The CNR measured from AIDR50 % images was also higher than that from the FBP images for the aorta relative to muscle (20.5 ± 9.0 vs. 18.3 ± 9.2, p < 0.0001). The interobserver agreement in the image quality score was excellent (κ = 0.82). The quality score was significantly higher for the AIDR50 % images compared to the FBP images (3.6 ± 0.6 vs. 3.3 ± 0.7, p = 0.004). Simulated radiation dose reduction applied to clinical coronary CTA images suggests that a 50 % reduction in radiation dose can be achieved with adaptive iterative dose reduction software with image quality that is at least comparable to images acquired at standard radiation exposure and reconstructed with filtered back projection.
format Online
Article
Text
id pubmed-3701132
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-37011322013-07-12 Simulated 50 % radiation dose reduction in coronary CT angiography using adaptive iterative dose reduction in three-dimensions (AIDR3D) Chen, Marcus Y. Steigner, Michael L. Leung, Steve W. Kumamaru, Kanako K. Schultz, Kurt Mather, Richard T. Arai, Andrew E. Rybicki, Frank J. Int J Cardiovasc Imaging Original Paper To compare the image quality of coronary CT angiography (CTA) studies between standard filtered back projection (FBP) and adaptive iterative dose reduction in three-dimensions (AIDR3D) reconstruction using CT noise additional software to simulate reduced radiation exposure. Images from 93 consecutive clinical coronary CTA studies were processed utilizing standard FBP, FBP with 50 % simulated dose reduction (FBP50 %), and AIDR3D with simulated 50 % dose reduction (AIDR50 %). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured within 5 regions-of-interest, and image quality for each reconstruction strategy was assessed by two independent readers using a 4-point scale. Compared to FBP, the SNR measured from the AIDR50 % images was similar or higher (airway: 38.3 ± 12.7 vs. 38.5 ± 14.5, p = 0.81, fat: 5.5 ± 1.9 vs. 5.4 ± 2.0, p = 0.20, muscle: 3.2 ± 1.2 vs. 3.1 ± 1.3, p = 0.38, aorta: 22.6 ± 9.4 vs. 20.2 ± 9.7, p < 0.0001, liver: 2.7 ± 1.0 vs. 2.3 ± 1.1, p < 0.0001), while the SNR of the FBP50 % images were all lower (p values < 0.0001). The CNR measured from AIDR50 % images was also higher than that from the FBP images for the aorta relative to muscle (20.5 ± 9.0 vs. 18.3 ± 9.2, p < 0.0001). The interobserver agreement in the image quality score was excellent (κ = 0.82). The quality score was significantly higher for the AIDR50 % images compared to the FBP images (3.6 ± 0.6 vs. 3.3 ± 0.7, p = 0.004). Simulated radiation dose reduction applied to clinical coronary CTA images suggests that a 50 % reduction in radiation dose can be achieved with adaptive iterative dose reduction software with image quality that is at least comparable to images acquired at standard radiation exposure and reconstructed with filtered back projection. Springer Netherlands 2013-02-13 2013 /pmc/articles/PMC3701132/ /pubmed/23404384 http://dx.doi.org/10.1007/s10554-013-0190-1 Text en © The Author(s) 2013 https://creativecommons.org/licenses/by/2.0/ Open AccessThis article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Original Paper
Chen, Marcus Y.
Steigner, Michael L.
Leung, Steve W.
Kumamaru, Kanako K.
Schultz, Kurt
Mather, Richard T.
Arai, Andrew E.
Rybicki, Frank J.
Simulated 50 % radiation dose reduction in coronary CT angiography using adaptive iterative dose reduction in three-dimensions (AIDR3D)
title Simulated 50 % radiation dose reduction in coronary CT angiography using adaptive iterative dose reduction in three-dimensions (AIDR3D)
title_full Simulated 50 % radiation dose reduction in coronary CT angiography using adaptive iterative dose reduction in three-dimensions (AIDR3D)
title_fullStr Simulated 50 % radiation dose reduction in coronary CT angiography using adaptive iterative dose reduction in three-dimensions (AIDR3D)
title_full_unstemmed Simulated 50 % radiation dose reduction in coronary CT angiography using adaptive iterative dose reduction in three-dimensions (AIDR3D)
title_short Simulated 50 % radiation dose reduction in coronary CT angiography using adaptive iterative dose reduction in three-dimensions (AIDR3D)
title_sort simulated 50 % radiation dose reduction in coronary ct angiography using adaptive iterative dose reduction in three-dimensions (aidr3d)
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3701132/
https://www.ncbi.nlm.nih.gov/pubmed/23404384
http://dx.doi.org/10.1007/s10554-013-0190-1
work_keys_str_mv AT chenmarcusy simulated50radiationdosereductionincoronaryctangiographyusingadaptiveiterativedosereductioninthreedimensionsaidr3d
AT steignermichaell simulated50radiationdosereductionincoronaryctangiographyusingadaptiveiterativedosereductioninthreedimensionsaidr3d
AT leungstevew simulated50radiationdosereductionincoronaryctangiographyusingadaptiveiterativedosereductioninthreedimensionsaidr3d
AT kumamarukanakok simulated50radiationdosereductionincoronaryctangiographyusingadaptiveiterativedosereductioninthreedimensionsaidr3d
AT schultzkurt simulated50radiationdosereductionincoronaryctangiographyusingadaptiveiterativedosereductioninthreedimensionsaidr3d
AT matherrichardt simulated50radiationdosereductionincoronaryctangiographyusingadaptiveiterativedosereductioninthreedimensionsaidr3d
AT araiandrewe simulated50radiationdosereductionincoronaryctangiographyusingadaptiveiterativedosereductioninthreedimensionsaidr3d
AT rybickifrankj simulated50radiationdosereductionincoronaryctangiographyusingadaptiveiterativedosereductioninthreedimensionsaidr3d