Cargando…
One-year hemodynamic comparison of Perimount Magna with St Jude Epic aortic bioprostheses
INTRODUCTION: Cardiac surgeons are using more bioprosthetic valves due to the ageing population as well as to improvements that have been made to these implants. We sought to compare the 1-year hemodynamics of two commercially available valves by echocardiographic parameters. MATERIAL AND METHODS: R...
Autores principales: | Bobiarski, Jerzy, Newcomb, Andrew E., Elhenawy, Abdelsalam M., Maganti, Manjula, Bos, Joanne, Hemeon, Suzanne, Rao, Vivek |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Termedia Publishing House
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3701989/ https://www.ncbi.nlm.nih.gov/pubmed/23847665 http://dx.doi.org/10.5114/aoms.2013.35479 |
Ejemplares similares
-
Significant intra-valvular pressure loss across EPIC SUPRA and perimount magna supra-annular designed aortic bioprostheses in patients with normal aortic size
por: Mohan, Jagdish C., et al.
Publicado: (2017) -
Mid-Term Clinical Outcomes and Hemodynamic Performances of Trifecta and Perimount Bioprostheses following Aortic Valve Replacement
por: Toto, Francesca, et al.
Publicado: (2023) -
Different Rates of Bioprosthetic Aortic Valve Failure With Perimount™ and Trifecta™ Bioprostheses
por: Lange, Rüdiger, et al.
Publicado: (2022) -
Serial echocardiographic evaluation of the Perimount Magna Ease prosthesis
por: Mayr, Benedikt, et al.
Publicado: (2021) -
Early calcific degeneration of the St. Jude Medical Epic aortic bioprosthesis
por: Izzat, Mohammad Bashar, et al.
Publicado: (2020)