Cargando…

A New Method for the Detection of Neutralizing Antibodies against Mumps Virus

Neutralization test is the most reliable method of evaluating immunity against viral diseases but there is no standard procedure for mumps virus, with tests differing in the infectivity of the challenge virus, 50% plaque reduction or complete inhibition of cytopathic effects (CPE), and usage of comp...

Descripción completa

Detalles Bibliográficos
Autores principales: Matsubara, Keita, Fujino, Motoko, Takeuchi, Kaoru, Iwata, Satoshi, Nakayama, Tetsuo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3702533/
https://www.ncbi.nlm.nih.gov/pubmed/23861738
http://dx.doi.org/10.1371/journal.pone.0065281
_version_ 1782275828109803520
author Matsubara, Keita
Fujino, Motoko
Takeuchi, Kaoru
Iwata, Satoshi
Nakayama, Tetsuo
author_facet Matsubara, Keita
Fujino, Motoko
Takeuchi, Kaoru
Iwata, Satoshi
Nakayama, Tetsuo
author_sort Matsubara, Keita
collection PubMed
description Neutralization test is the most reliable method of evaluating immunity against viral diseases but there is no standard procedure for mumps virus, with tests differing in the infectivity of the challenge virus, 50% plaque reduction or complete inhibition of cytopathic effects (CPE), and usage of complement. A reliable, easy, and simple neutralization test for mumps virus was developed in this study. A recombinant mumps virus expressing GFP was generated as a challenge virus. Complement was added to the neutralizing mixture at 1∶200 when stocked serum samples were used. Neutralizing antibody titers were expressed as the reciprocal of the highest dilution that did not exceed two-fold of FU values (GFP expression) of the cell control wells. A total of 1,452 serum samples were assayed by inhibition of GFP expression in comparison with those examined by conventional 100% inhibition of CPE. 1,367 (94.1%) showed similar neutralizing antibody titers when examined by both methods. The GFP expression inhibition assay, using a recombinant mumps virus expressing GFP, is a simple and time- saving method.
format Online
Article
Text
id pubmed-3702533
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-37025332013-07-16 A New Method for the Detection of Neutralizing Antibodies against Mumps Virus Matsubara, Keita Fujino, Motoko Takeuchi, Kaoru Iwata, Satoshi Nakayama, Tetsuo PLoS One Research Article Neutralization test is the most reliable method of evaluating immunity against viral diseases but there is no standard procedure for mumps virus, with tests differing in the infectivity of the challenge virus, 50% plaque reduction or complete inhibition of cytopathic effects (CPE), and usage of complement. A reliable, easy, and simple neutralization test for mumps virus was developed in this study. A recombinant mumps virus expressing GFP was generated as a challenge virus. Complement was added to the neutralizing mixture at 1∶200 when stocked serum samples were used. Neutralizing antibody titers were expressed as the reciprocal of the highest dilution that did not exceed two-fold of FU values (GFP expression) of the cell control wells. A total of 1,452 serum samples were assayed by inhibition of GFP expression in comparison with those examined by conventional 100% inhibition of CPE. 1,367 (94.1%) showed similar neutralizing antibody titers when examined by both methods. The GFP expression inhibition assay, using a recombinant mumps virus expressing GFP, is a simple and time- saving method. Public Library of Science 2013-07-05 /pmc/articles/PMC3702533/ /pubmed/23861738 http://dx.doi.org/10.1371/journal.pone.0065281 Text en © 2013 Matsubara et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Matsubara, Keita
Fujino, Motoko
Takeuchi, Kaoru
Iwata, Satoshi
Nakayama, Tetsuo
A New Method for the Detection of Neutralizing Antibodies against Mumps Virus
title A New Method for the Detection of Neutralizing Antibodies against Mumps Virus
title_full A New Method for the Detection of Neutralizing Antibodies against Mumps Virus
title_fullStr A New Method for the Detection of Neutralizing Antibodies against Mumps Virus
title_full_unstemmed A New Method for the Detection of Neutralizing Antibodies against Mumps Virus
title_short A New Method for the Detection of Neutralizing Antibodies against Mumps Virus
title_sort new method for the detection of neutralizing antibodies against mumps virus
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3702533/
https://www.ncbi.nlm.nih.gov/pubmed/23861738
http://dx.doi.org/10.1371/journal.pone.0065281
work_keys_str_mv AT matsubarakeita anewmethodforthedetectionofneutralizingantibodiesagainstmumpsvirus
AT fujinomotoko anewmethodforthedetectionofneutralizingantibodiesagainstmumpsvirus
AT takeuchikaoru anewmethodforthedetectionofneutralizingantibodiesagainstmumpsvirus
AT iwatasatoshi anewmethodforthedetectionofneutralizingantibodiesagainstmumpsvirus
AT nakayamatetsuo anewmethodforthedetectionofneutralizingantibodiesagainstmumpsvirus
AT matsubarakeita newmethodforthedetectionofneutralizingantibodiesagainstmumpsvirus
AT fujinomotoko newmethodforthedetectionofneutralizingantibodiesagainstmumpsvirus
AT takeuchikaoru newmethodforthedetectionofneutralizingantibodiesagainstmumpsvirus
AT iwatasatoshi newmethodforthedetectionofneutralizingantibodiesagainstmumpsvirus
AT nakayamatetsuo newmethodforthedetectionofneutralizingantibodiesagainstmumpsvirus