Cargando…
Arrival time parametric imaging using Sonazoid-enhanced ultrasonography is useful for the detection of spoke-wheel patterns of focal nodular hyperplasia smaller than 3 cm
It is considered difficult to make a definitive diagnosis of focal nodular hyperplasia (FNH) of <3 cm when using conventional diagnostic imaging modalities. Typical FNH imaging findings are: i) central scar formation, ii) nutrient vessels extending radially from the center and iii) the presence o...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
D.A. Spandidos
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3702692/ https://www.ncbi.nlm.nih.gov/pubmed/23837029 http://dx.doi.org/10.3892/etm.2013.1048 |
_version_ | 1782275850701373440 |
---|---|
author | WAKUI, NORITAKA TAKAYAMA, RYUJI KAMIYAMA, NAOHISA KOBAYASHI, KOJIRO MATSUI, DAIGO MATSUKIYO, YASUSHI KANEKAWA, TAKENORI IKEHARA, TAKASHI ISHII, KOJI SUMINO, YASUKIYO |
author_facet | WAKUI, NORITAKA TAKAYAMA, RYUJI KAMIYAMA, NAOHISA KOBAYASHI, KOJIRO MATSUI, DAIGO MATSUKIYO, YASUSHI KANEKAWA, TAKENORI IKEHARA, TAKASHI ISHII, KOJI SUMINO, YASUKIYO |
author_sort | WAKUI, NORITAKA |
collection | PubMed |
description | It is considered difficult to make a definitive diagnosis of focal nodular hyperplasia (FNH) of <3 cm when using conventional diagnostic imaging modalities. Typical FNH imaging findings are: i) central scar formation, ii) nutrient vessels extending radially from the center and iii) the presence of Kupffer cells. In a clinical setting, identification of a spoke-wheel pattern formed by nutrient vessels extending radially is a key feature in the diagnosis of FNH. In this study, we investigated the detection rate of spoke-wheel patterns of FNH <3 cm using arrival time parametric imaging (At-PI) technology with Sonazoid-enhanced ultrasonography (US). Five patients with FNH <3 cm who had undergone Sonazoid-enhanced US at the Toho University Omori Medical Center between February 2008 and March 2009 were included in the study. The mean tumor diameter was 20.2±7.2 mm. Lesions were enhanced with 0.5 ml Sonazoid US contrast agent and a video of the procedure was saved and used for At-PI analysis of contrast agent dynamics in FNH. Three ultrasonographic specialists examined the images and made a diagnosis of FNH based on the findings of spoke-wheel patterns. Similarly, micro-flow imaging (MFI) was performed to evaluate the contrast agent dynamics in FNH. Using MFI, FNH was diagnosed in 3 of the 5 cases by the three specialists, whereas At-PI enabled the identification of spoke-wheel patterns in all 5 cases. At-PI using Sonazoid-enhanced US is superior for detecting spoke-wheel patterns of FNH <3 cm. |
format | Online Article Text |
id | pubmed-3702692 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | D.A. Spandidos |
record_format | MEDLINE/PubMed |
spelling | pubmed-37026922013-07-08 Arrival time parametric imaging using Sonazoid-enhanced ultrasonography is useful for the detection of spoke-wheel patterns of focal nodular hyperplasia smaller than 3 cm WAKUI, NORITAKA TAKAYAMA, RYUJI KAMIYAMA, NAOHISA KOBAYASHI, KOJIRO MATSUI, DAIGO MATSUKIYO, YASUSHI KANEKAWA, TAKENORI IKEHARA, TAKASHI ISHII, KOJI SUMINO, YASUKIYO Exp Ther Med Articles It is considered difficult to make a definitive diagnosis of focal nodular hyperplasia (FNH) of <3 cm when using conventional diagnostic imaging modalities. Typical FNH imaging findings are: i) central scar formation, ii) nutrient vessels extending radially from the center and iii) the presence of Kupffer cells. In a clinical setting, identification of a spoke-wheel pattern formed by nutrient vessels extending radially is a key feature in the diagnosis of FNH. In this study, we investigated the detection rate of spoke-wheel patterns of FNH <3 cm using arrival time parametric imaging (At-PI) technology with Sonazoid-enhanced ultrasonography (US). Five patients with FNH <3 cm who had undergone Sonazoid-enhanced US at the Toho University Omori Medical Center between February 2008 and March 2009 were included in the study. The mean tumor diameter was 20.2±7.2 mm. Lesions were enhanced with 0.5 ml Sonazoid US contrast agent and a video of the procedure was saved and used for At-PI analysis of contrast agent dynamics in FNH. Three ultrasonographic specialists examined the images and made a diagnosis of FNH based on the findings of spoke-wheel patterns. Similarly, micro-flow imaging (MFI) was performed to evaluate the contrast agent dynamics in FNH. Using MFI, FNH was diagnosed in 3 of the 5 cases by the three specialists, whereas At-PI enabled the identification of spoke-wheel patterns in all 5 cases. At-PI using Sonazoid-enhanced US is superior for detecting spoke-wheel patterns of FNH <3 cm. D.A. Spandidos 2013-06 2013-04-04 /pmc/articles/PMC3702692/ /pubmed/23837029 http://dx.doi.org/10.3892/etm.2013.1048 Text en Copyright © 2013, Spandidos Publications http://creativecommons.org/licenses/by/3.0 This is an open-access article licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License. The article may be redistributed, reproduced, and reused for non-commercial purposes, provided the original source is properly cited. |
spellingShingle | Articles WAKUI, NORITAKA TAKAYAMA, RYUJI KAMIYAMA, NAOHISA KOBAYASHI, KOJIRO MATSUI, DAIGO MATSUKIYO, YASUSHI KANEKAWA, TAKENORI IKEHARA, TAKASHI ISHII, KOJI SUMINO, YASUKIYO Arrival time parametric imaging using Sonazoid-enhanced ultrasonography is useful for the detection of spoke-wheel patterns of focal nodular hyperplasia smaller than 3 cm |
title | Arrival time parametric imaging using Sonazoid-enhanced ultrasonography is useful for the detection of spoke-wheel patterns of focal nodular hyperplasia smaller than 3 cm |
title_full | Arrival time parametric imaging using Sonazoid-enhanced ultrasonography is useful for the detection of spoke-wheel patterns of focal nodular hyperplasia smaller than 3 cm |
title_fullStr | Arrival time parametric imaging using Sonazoid-enhanced ultrasonography is useful for the detection of spoke-wheel patterns of focal nodular hyperplasia smaller than 3 cm |
title_full_unstemmed | Arrival time parametric imaging using Sonazoid-enhanced ultrasonography is useful for the detection of spoke-wheel patterns of focal nodular hyperplasia smaller than 3 cm |
title_short | Arrival time parametric imaging using Sonazoid-enhanced ultrasonography is useful for the detection of spoke-wheel patterns of focal nodular hyperplasia smaller than 3 cm |
title_sort | arrival time parametric imaging using sonazoid-enhanced ultrasonography is useful for the detection of spoke-wheel patterns of focal nodular hyperplasia smaller than 3 cm |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3702692/ https://www.ncbi.nlm.nih.gov/pubmed/23837029 http://dx.doi.org/10.3892/etm.2013.1048 |
work_keys_str_mv | AT wakuinoritaka arrivaltimeparametricimagingusingsonazoidenhancedultrasonographyisusefulforthedetectionofspokewheelpatternsoffocalnodularhyperplasiasmallerthan3cm AT takayamaryuji arrivaltimeparametricimagingusingsonazoidenhancedultrasonographyisusefulforthedetectionofspokewheelpatternsoffocalnodularhyperplasiasmallerthan3cm AT kamiyamanaohisa arrivaltimeparametricimagingusingsonazoidenhancedultrasonographyisusefulforthedetectionofspokewheelpatternsoffocalnodularhyperplasiasmallerthan3cm AT kobayashikojiro arrivaltimeparametricimagingusingsonazoidenhancedultrasonographyisusefulforthedetectionofspokewheelpatternsoffocalnodularhyperplasiasmallerthan3cm AT matsuidaigo arrivaltimeparametricimagingusingsonazoidenhancedultrasonographyisusefulforthedetectionofspokewheelpatternsoffocalnodularhyperplasiasmallerthan3cm AT matsukiyoyasushi arrivaltimeparametricimagingusingsonazoidenhancedultrasonographyisusefulforthedetectionofspokewheelpatternsoffocalnodularhyperplasiasmallerthan3cm AT kanekawatakenori arrivaltimeparametricimagingusingsonazoidenhancedultrasonographyisusefulforthedetectionofspokewheelpatternsoffocalnodularhyperplasiasmallerthan3cm AT ikeharatakashi arrivaltimeparametricimagingusingsonazoidenhancedultrasonographyisusefulforthedetectionofspokewheelpatternsoffocalnodularhyperplasiasmallerthan3cm AT ishiikoji arrivaltimeparametricimagingusingsonazoidenhancedultrasonographyisusefulforthedetectionofspokewheelpatternsoffocalnodularhyperplasiasmallerthan3cm AT suminoyasukiyo arrivaltimeparametricimagingusingsonazoidenhancedultrasonographyisusefulforthedetectionofspokewheelpatternsoffocalnodularhyperplasiasmallerthan3cm |