Determination of Parathion and Carbaryl Pesticides in Water and Food Samples Using a Self Assembled Monolayer/Acetylcholinesterase Electrochemical Biosensor

An acetylcholinesterase (AchE) based amperometric biosensor was developed by immobilisation of the enzyme onto a self assembled modified gold electrode. Cyclic voltammetric experiments performed with the SAM-AchE biosensor in phosphate buffer solutions (pH = 7.2) containing acetylthiocholine confirm...

Descripción completa

Detalles Bibliográficos
Autores principales: Pedrosa, Valber A., Caetano, Josiane, Machado, Sergio A. S., Bertotti, Mauro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3705461/
https://www.ncbi.nlm.nih.gov/pubmed/27873775
http://dx.doi.org/10.3390/s8084600
_version_ 1782476441923878912
author Pedrosa, Valber A.
Caetano, Josiane
Machado, Sergio A. S.
Bertotti, Mauro
author_facet Pedrosa, Valber A.
Caetano, Josiane
Machado, Sergio A. S.
Bertotti, Mauro
author_sort Pedrosa, Valber A.
collection PubMed
description An acetylcholinesterase (AchE) based amperometric biosensor was developed by immobilisation of the enzyme onto a self assembled modified gold electrode. Cyclic voltammetric experiments performed with the SAM-AchE biosensor in phosphate buffer solutions (pH = 7.2) containing acetylthiocholine confirmed the formation of thiocholine and its electrochemical oxidation at E(p) = 0.28 V vs Ag/AgCl. An indirect methodology involving the inhibition effect of parathion and carbaryl on the enzymatic reaction was developed and employed to measure both pesticides in spiked natural water and food samples without pre-treatment or pre-concentration steps. Values higher than 91-98.0% in recovery experiments indicated the feasibility of the proposed electroanalytical methodology to quantify both pesticides in water or food samples. HPLC measurements were also performed for comparison and confirmed the values measured amperometrically.
format Online
Article
Text
id pubmed-3705461
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-37054612013-07-09 Determination of Parathion and Carbaryl Pesticides in Water and Food Samples Using a Self Assembled Monolayer/Acetylcholinesterase Electrochemical Biosensor Pedrosa, Valber A. Caetano, Josiane Machado, Sergio A. S. Bertotti, Mauro Sensors (Basel) Article An acetylcholinesterase (AchE) based amperometric biosensor was developed by immobilisation of the enzyme onto a self assembled modified gold electrode. Cyclic voltammetric experiments performed with the SAM-AchE biosensor in phosphate buffer solutions (pH = 7.2) containing acetylthiocholine confirmed the formation of thiocholine and its electrochemical oxidation at E(p) = 0.28 V vs Ag/AgCl. An indirect methodology involving the inhibition effect of parathion and carbaryl on the enzymatic reaction was developed and employed to measure both pesticides in spiked natural water and food samples without pre-treatment or pre-concentration steps. Values higher than 91-98.0% in recovery experiments indicated the feasibility of the proposed electroanalytical methodology to quantify both pesticides in water or food samples. HPLC measurements were also performed for comparison and confirmed the values measured amperometrically. Molecular Diversity Preservation International (MDPI) 2008-08-05 /pmc/articles/PMC3705461/ /pubmed/27873775 http://dx.doi.org/10.3390/s8084600 Text en © 2008 by the authors; licensee Molecular Diversity Preservation International, Basel, Switzerland. This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Pedrosa, Valber A.
Caetano, Josiane
Machado, Sergio A. S.
Bertotti, Mauro
Determination of Parathion and Carbaryl Pesticides in Water and Food Samples Using a Self Assembled Monolayer/Acetylcholinesterase Electrochemical Biosensor
title Determination of Parathion and Carbaryl Pesticides in Water and Food Samples Using a Self Assembled Monolayer/Acetylcholinesterase Electrochemical Biosensor
title_full Determination of Parathion and Carbaryl Pesticides in Water and Food Samples Using a Self Assembled Monolayer/Acetylcholinesterase Electrochemical Biosensor
title_fullStr Determination of Parathion and Carbaryl Pesticides in Water and Food Samples Using a Self Assembled Monolayer/Acetylcholinesterase Electrochemical Biosensor
title_full_unstemmed Determination of Parathion and Carbaryl Pesticides in Water and Food Samples Using a Self Assembled Monolayer/Acetylcholinesterase Electrochemical Biosensor
title_short Determination of Parathion and Carbaryl Pesticides in Water and Food Samples Using a Self Assembled Monolayer/Acetylcholinesterase Electrochemical Biosensor
title_sort determination of parathion and carbaryl pesticides in water and food samples using a self assembled monolayer/acetylcholinesterase electrochemical biosensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3705461/
https://www.ncbi.nlm.nih.gov/pubmed/27873775
http://dx.doi.org/10.3390/s8084600
work_keys_str_mv AT pedrosavalbera determinationofparathionandcarbarylpesticidesinwaterandfoodsamplesusingaselfassembledmonolayeracetylcholinesteraseelectrochemicalbiosensor
AT caetanojosiane determinationofparathionandcarbarylpesticidesinwaterandfoodsamplesusingaselfassembledmonolayeracetylcholinesteraseelectrochemicalbiosensor
AT machadosergioas determinationofparathionandcarbarylpesticidesinwaterandfoodsamplesusingaselfassembledmonolayeracetylcholinesteraseelectrochemicalbiosensor
AT bertottimauro determinationofparathionandcarbarylpesticidesinwaterandfoodsamplesusingaselfassembledmonolayeracetylcholinesteraseelectrochemicalbiosensor