Cargando…
Determination of Parathion and Carbaryl Pesticides in Water and Food Samples Using a Self Assembled Monolayer/Acetylcholinesterase Electrochemical Biosensor
An acetylcholinesterase (AchE) based amperometric biosensor was developed by immobilisation of the enzyme onto a self assembled modified gold electrode. Cyclic voltammetric experiments performed with the SAM-AchE biosensor in phosphate buffer solutions (pH = 7.2) containing acetylthiocholine confirm...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3705461/ https://www.ncbi.nlm.nih.gov/pubmed/27873775 http://dx.doi.org/10.3390/s8084600 |
_version_ | 1782476441923878912 |
---|---|
author | Pedrosa, Valber A. Caetano, Josiane Machado, Sergio A. S. Bertotti, Mauro |
author_facet | Pedrosa, Valber A. Caetano, Josiane Machado, Sergio A. S. Bertotti, Mauro |
author_sort | Pedrosa, Valber A. |
collection | PubMed |
description | An acetylcholinesterase (AchE) based amperometric biosensor was developed by immobilisation of the enzyme onto a self assembled modified gold electrode. Cyclic voltammetric experiments performed with the SAM-AchE biosensor in phosphate buffer solutions (pH = 7.2) containing acetylthiocholine confirmed the formation of thiocholine and its electrochemical oxidation at E(p) = 0.28 V vs Ag/AgCl. An indirect methodology involving the inhibition effect of parathion and carbaryl on the enzymatic reaction was developed and employed to measure both pesticides in spiked natural water and food samples without pre-treatment or pre-concentration steps. Values higher than 91-98.0% in recovery experiments indicated the feasibility of the proposed electroanalytical methodology to quantify both pesticides in water or food samples. HPLC measurements were also performed for comparison and confirmed the values measured amperometrically. |
format | Online Article Text |
id | pubmed-3705461 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-37054612013-07-09 Determination of Parathion and Carbaryl Pesticides in Water and Food Samples Using a Self Assembled Monolayer/Acetylcholinesterase Electrochemical Biosensor Pedrosa, Valber A. Caetano, Josiane Machado, Sergio A. S. Bertotti, Mauro Sensors (Basel) Article An acetylcholinesterase (AchE) based amperometric biosensor was developed by immobilisation of the enzyme onto a self assembled modified gold electrode. Cyclic voltammetric experiments performed with the SAM-AchE biosensor in phosphate buffer solutions (pH = 7.2) containing acetylthiocholine confirmed the formation of thiocholine and its electrochemical oxidation at E(p) = 0.28 V vs Ag/AgCl. An indirect methodology involving the inhibition effect of parathion and carbaryl on the enzymatic reaction was developed and employed to measure both pesticides in spiked natural water and food samples without pre-treatment or pre-concentration steps. Values higher than 91-98.0% in recovery experiments indicated the feasibility of the proposed electroanalytical methodology to quantify both pesticides in water or food samples. HPLC measurements were also performed for comparison and confirmed the values measured amperometrically. Molecular Diversity Preservation International (MDPI) 2008-08-05 /pmc/articles/PMC3705461/ /pubmed/27873775 http://dx.doi.org/10.3390/s8084600 Text en © 2008 by the authors; licensee Molecular Diversity Preservation International, Basel, Switzerland. This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Pedrosa, Valber A. Caetano, Josiane Machado, Sergio A. S. Bertotti, Mauro Determination of Parathion and Carbaryl Pesticides in Water and Food Samples Using a Self Assembled Monolayer/Acetylcholinesterase Electrochemical Biosensor |
title | Determination of Parathion and Carbaryl Pesticides in Water and Food Samples Using a Self Assembled Monolayer/Acetylcholinesterase Electrochemical Biosensor |
title_full | Determination of Parathion and Carbaryl Pesticides in Water and Food Samples Using a Self Assembled Monolayer/Acetylcholinesterase Electrochemical Biosensor |
title_fullStr | Determination of Parathion and Carbaryl Pesticides in Water and Food Samples Using a Self Assembled Monolayer/Acetylcholinesterase Electrochemical Biosensor |
title_full_unstemmed | Determination of Parathion and Carbaryl Pesticides in Water and Food Samples Using a Self Assembled Monolayer/Acetylcholinesterase Electrochemical Biosensor |
title_short | Determination of Parathion and Carbaryl Pesticides in Water and Food Samples Using a Self Assembled Monolayer/Acetylcholinesterase Electrochemical Biosensor |
title_sort | determination of parathion and carbaryl pesticides in water and food samples using a self assembled monolayer/acetylcholinesterase electrochemical biosensor |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3705461/ https://www.ncbi.nlm.nih.gov/pubmed/27873775 http://dx.doi.org/10.3390/s8084600 |
work_keys_str_mv | AT pedrosavalbera determinationofparathionandcarbarylpesticidesinwaterandfoodsamplesusingaselfassembledmonolayeracetylcholinesteraseelectrochemicalbiosensor AT caetanojosiane determinationofparathionandcarbarylpesticidesinwaterandfoodsamplesusingaselfassembledmonolayeracetylcholinesteraseelectrochemicalbiosensor AT machadosergioas determinationofparathionandcarbarylpesticidesinwaterandfoodsamplesusingaselfassembledmonolayeracetylcholinesteraseelectrochemicalbiosensor AT bertottimauro determinationofparathionandcarbarylpesticidesinwaterandfoodsamplesusingaselfassembledmonolayeracetylcholinesteraseelectrochemicalbiosensor |