Cargando…

Surface Heat Balance Analysis of Tainan City on March 6, 2001 Using ASTER and Formosat-2 Data

The urban heat island phenomenon occurs as a mixed result of anthropogenic heat discharge, decreased vegetation, and increased artificial impervious surfaces. To clarify the contribution of each factor to the urban heat island, it is necessary to evaluate the surface heat balance. Satellite remote s...

Descripción completa

Detalles Bibliográficos
Autores principales: Kato, Soushi, Yamaguchi, Yasushi, Liu, Cheng-Chien, Sun, Chen-Yi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3705546/
https://www.ncbi.nlm.nih.gov/pubmed/27873856
http://dx.doi.org/10.3390/s8096026
_version_ 1782476460478431232
author Kato, Soushi
Yamaguchi, Yasushi
Liu, Cheng-Chien
Sun, Chen-Yi
author_facet Kato, Soushi
Yamaguchi, Yasushi
Liu, Cheng-Chien
Sun, Chen-Yi
author_sort Kato, Soushi
collection PubMed
description The urban heat island phenomenon occurs as a mixed result of anthropogenic heat discharge, decreased vegetation, and increased artificial impervious surfaces. To clarify the contribution of each factor to the urban heat island, it is necessary to evaluate the surface heat balance. Satellite remote sensing data of Tainan City, Taiwan, obtained from Terra ASTER and Formosat-2 were used to estimate surface heat balance in this study. ASTER data is suitable for analyzing heat balance because of the wide spectral range. We used Formosat-2 multispectral data to classify the land surface, which was used to interpolate some surface parameters for estimating heat fluxes. Because of the high spatial resolution of the Formosat-2 image, more roads, open spaces and small vegetation areas could be distinguished from buildings in urban areas; however, misclassifications of land cover in such areas using ASTER data would overestimate the sensible heat flux. On the other hand, the small vegetated areas detected from the Formosat-2 image slightly increased the estimation of latent heat flux. As a result, the storage heat flux derived from Formosat-2 is higher than that derived from ASTER data in most areas. From these results, we can conclude that the higher resolution land coverage map increases accuracy of the heat balance analysis. Storage heat flux occupies about 60 to 80% of the net radiation in most of the artificial surface areas in spite of their usages. Because of the homogeneity of the building roof materials, there is no contrast between the storage heat flux in business and residential areas. In sparsely vegetated urban areas, more heat is stored and latent heat is smaller than that in the forested suburbs. This result implies that density of vegetation has a significant influence in decreasing temperatures.
format Online
Article
Text
id pubmed-3705546
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-37055462013-07-09 Surface Heat Balance Analysis of Tainan City on March 6, 2001 Using ASTER and Formosat-2 Data Kato, Soushi Yamaguchi, Yasushi Liu, Cheng-Chien Sun, Chen-Yi Sensors (Basel) Article The urban heat island phenomenon occurs as a mixed result of anthropogenic heat discharge, decreased vegetation, and increased artificial impervious surfaces. To clarify the contribution of each factor to the urban heat island, it is necessary to evaluate the surface heat balance. Satellite remote sensing data of Tainan City, Taiwan, obtained from Terra ASTER and Formosat-2 were used to estimate surface heat balance in this study. ASTER data is suitable for analyzing heat balance because of the wide spectral range. We used Formosat-2 multispectral data to classify the land surface, which was used to interpolate some surface parameters for estimating heat fluxes. Because of the high spatial resolution of the Formosat-2 image, more roads, open spaces and small vegetation areas could be distinguished from buildings in urban areas; however, misclassifications of land cover in such areas using ASTER data would overestimate the sensible heat flux. On the other hand, the small vegetated areas detected from the Formosat-2 image slightly increased the estimation of latent heat flux. As a result, the storage heat flux derived from Formosat-2 is higher than that derived from ASTER data in most areas. From these results, we can conclude that the higher resolution land coverage map increases accuracy of the heat balance analysis. Storage heat flux occupies about 60 to 80% of the net radiation in most of the artificial surface areas in spite of their usages. Because of the homogeneity of the building roof materials, there is no contrast between the storage heat flux in business and residential areas. In sparsely vegetated urban areas, more heat is stored and latent heat is smaller than that in the forested suburbs. This result implies that density of vegetation has a significant influence in decreasing temperatures. Molecular Diversity Preservation International (MDPI) 2008-09-26 /pmc/articles/PMC3705546/ /pubmed/27873856 http://dx.doi.org/10.3390/s8096026 Text en © by the authors; licensee Molecular Diversity Preservation International, Basel, Switzerland. This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Kato, Soushi
Yamaguchi, Yasushi
Liu, Cheng-Chien
Sun, Chen-Yi
Surface Heat Balance Analysis of Tainan City on March 6, 2001 Using ASTER and Formosat-2 Data
title Surface Heat Balance Analysis of Tainan City on March 6, 2001 Using ASTER and Formosat-2 Data
title_full Surface Heat Balance Analysis of Tainan City on March 6, 2001 Using ASTER and Formosat-2 Data
title_fullStr Surface Heat Balance Analysis of Tainan City on March 6, 2001 Using ASTER and Formosat-2 Data
title_full_unstemmed Surface Heat Balance Analysis of Tainan City on March 6, 2001 Using ASTER and Formosat-2 Data
title_short Surface Heat Balance Analysis of Tainan City on March 6, 2001 Using ASTER and Formosat-2 Data
title_sort surface heat balance analysis of tainan city on march 6, 2001 using aster and formosat-2 data
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3705546/
https://www.ncbi.nlm.nih.gov/pubmed/27873856
http://dx.doi.org/10.3390/s8096026
work_keys_str_mv AT katosoushi surfaceheatbalanceanalysisoftainancityonmarch62001usingasterandformosat2data
AT yamaguchiyasushi surfaceheatbalanceanalysisoftainancityonmarch62001usingasterandformosat2data
AT liuchengchien surfaceheatbalanceanalysisoftainancityonmarch62001usingasterandformosat2data
AT sunchenyi surfaceheatbalanceanalysisoftainancityonmarch62001usingasterandformosat2data