Cargando…

Pre-Launch Absolute Calibration of CCD/CBERS-2B Sensor

Pre-launch absolute calibration coefficients for the CCD/CBERS-2B sensor have been calculated from radiometric measurements performed in a satellite integration and test hall in the Chinese Academy of Space Technology (CAST) headquarters, located in Beijing, China. An illuminated integrating sphere...

Descripción completa

Detalles Bibliográficos
Autores principales: Ponzoni, Flávio Jorge, Albuquerque, Bráulio Fonseca Carneiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3707467/
https://www.ncbi.nlm.nih.gov/pubmed/27873886
http://dx.doi.org/10.3390/s8106557
_version_ 1782276508416475136
author Ponzoni, Flávio Jorge
Albuquerque, Bráulio Fonseca Carneiro
author_facet Ponzoni, Flávio Jorge
Albuquerque, Bráulio Fonseca Carneiro
author_sort Ponzoni, Flávio Jorge
collection PubMed
description Pre-launch absolute calibration coefficients for the CCD/CBERS-2B sensor have been calculated from radiometric measurements performed in a satellite integration and test hall in the Chinese Academy of Space Technology (CAST) headquarters, located in Beijing, China. An illuminated integrating sphere was positioned in the test hall facilities to allow the CCD/CBERS-2B imagery of the entire sphere aperture. Calibration images were recorded and a relative calibration procedure adopted exclusively in Brazil was applied to equalize the detectors responses. Averages of digital numbers (DN) from these images were determined and correlated to their respective radiance levels in order to calculate the absolute calibration coefficients. It has been the first time these pre-launch absolute calibration coefficients have been calculated considering the Brazilian image processing criteria. Now it will be possible to compare them to those that will be calculated from vicarious calibration campaigns. This comparison will permit the CCD/CBERS-2B monitoring and the frequently data updating to the user community.
format Online
Article
Text
id pubmed-3707467
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-37074672013-07-10 Pre-Launch Absolute Calibration of CCD/CBERS-2B Sensor Ponzoni, Flávio Jorge Albuquerque, Bráulio Fonseca Carneiro Sensors (Basel) Article Pre-launch absolute calibration coefficients for the CCD/CBERS-2B sensor have been calculated from radiometric measurements performed in a satellite integration and test hall in the Chinese Academy of Space Technology (CAST) headquarters, located in Beijing, China. An illuminated integrating sphere was positioned in the test hall facilities to allow the CCD/CBERS-2B imagery of the entire sphere aperture. Calibration images were recorded and a relative calibration procedure adopted exclusively in Brazil was applied to equalize the detectors responses. Averages of digital numbers (DN) from these images were determined and correlated to their respective radiance levels in order to calculate the absolute calibration coefficients. It has been the first time these pre-launch absolute calibration coefficients have been calculated considering the Brazilian image processing criteria. Now it will be possible to compare them to those that will be calculated from vicarious calibration campaigns. This comparison will permit the CCD/CBERS-2B monitoring and the frequently data updating to the user community. Molecular Diversity Preservation International (MDPI) 2008-10-23 /pmc/articles/PMC3707467/ /pubmed/27873886 http://dx.doi.org/10.3390/s8106557 Text en © 2008 by the authors; licensee Molecular Diversity Preservation International, Basel, Switzerland. This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Ponzoni, Flávio Jorge
Albuquerque, Bráulio Fonseca Carneiro
Pre-Launch Absolute Calibration of CCD/CBERS-2B Sensor
title Pre-Launch Absolute Calibration of CCD/CBERS-2B Sensor
title_full Pre-Launch Absolute Calibration of CCD/CBERS-2B Sensor
title_fullStr Pre-Launch Absolute Calibration of CCD/CBERS-2B Sensor
title_full_unstemmed Pre-Launch Absolute Calibration of CCD/CBERS-2B Sensor
title_short Pre-Launch Absolute Calibration of CCD/CBERS-2B Sensor
title_sort pre-launch absolute calibration of ccd/cbers-2b sensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3707467/
https://www.ncbi.nlm.nih.gov/pubmed/27873886
http://dx.doi.org/10.3390/s8106557
work_keys_str_mv AT ponzoniflaviojorge prelaunchabsolutecalibrationofccdcbers2bsensor
AT albuquerquebrauliofonsecacarneiro prelaunchabsolutecalibrationofccdcbers2bsensor