Inter-observer agreement and diagnostic accuracy of myocardial perfusion reserve quantification by cardiovascular magnetic resonance at 3 Tesla in comparison to quantitative coronary angiography

BACKGROUND: Quantification of cardiovascular magnetic resonance (CMR) myocardial perfusion reserve (MPR) at 1.5 Tesla has been shown to correlate to invasive evaluation of coronary artery disease (CAD) and to yield good inter-observer agreement. However, little is known about quantitative adenosine-...

Descripción completa

Detalles Bibliográficos
Autores principales: Ikuye, Katharina, Buckert, Dominik, Schaaf, Lisa, Walcher, Thomas, Rottbauer, Wolfgang, Bernhardt, Peter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3707831/
https://www.ncbi.nlm.nih.gov/pubmed/23537061
http://dx.doi.org/10.1186/1532-429X-15-25
_version_ 1782276543510216704
author Ikuye, Katharina
Buckert, Dominik
Schaaf, Lisa
Walcher, Thomas
Rottbauer, Wolfgang
Bernhardt, Peter
author_facet Ikuye, Katharina
Buckert, Dominik
Schaaf, Lisa
Walcher, Thomas
Rottbauer, Wolfgang
Bernhardt, Peter
author_sort Ikuye, Katharina
collection PubMed
description BACKGROUND: Quantification of cardiovascular magnetic resonance (CMR) myocardial perfusion reserve (MPR) at 1.5 Tesla has been shown to correlate to invasive evaluation of coronary artery disease (CAD) and to yield good inter-observer agreement. However, little is known about quantitative adenosine-perfusion CMR at 3 Tesla and no data about inter-observer agreement is available. Aim of our study was to evaluate inter-observer agreement and to assess the diagnostic accuracy in comparison to quantitative coronary angiography (QCA). METHODS: Fifty-three patients referred for coronary x-ray angiography were previously examined in a 3 Tesla whole-body scanner. Adenosine and rest perfusion CMR were acquired for the quantification of MPR in all segments. Two blinded and independent readers analyzed all images. QCA was performed in case of coronary stenosis. QCA data was used to assess diagnostic accuracy of the MPR measurements. RESULTS: Inter-observer agreement was high for all myocardial perfusion territories (ρ = 0.92 for LAD, ρ = 0.93 for CX and RCA perfused segments). Compared to QCA receiver-operating characteristics yielded an area under the curve of 0.78 and 0.73 for RCA, 0.66 and 0.69 for LAD, and 0.52 and 0.53 for LCX perfused territories. CONCLUSIONS: Inter-observer agreement of MPR quantification at 3 Tesla CMR is very high for all myocardial segments. Diagnostic accuracy in comparison to QCA yields good values for the RCA and LAD perfused territories, but moderate values for the posterior LCX perfused myocardial segments.
format Online
Article
Text
id pubmed-3707831
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-37078312013-07-11 Inter-observer agreement and diagnostic accuracy of myocardial perfusion reserve quantification by cardiovascular magnetic resonance at 3 Tesla in comparison to quantitative coronary angiography Ikuye, Katharina Buckert, Dominik Schaaf, Lisa Walcher, Thomas Rottbauer, Wolfgang Bernhardt, Peter J Cardiovasc Magn Reson Research BACKGROUND: Quantification of cardiovascular magnetic resonance (CMR) myocardial perfusion reserve (MPR) at 1.5 Tesla has been shown to correlate to invasive evaluation of coronary artery disease (CAD) and to yield good inter-observer agreement. However, little is known about quantitative adenosine-perfusion CMR at 3 Tesla and no data about inter-observer agreement is available. Aim of our study was to evaluate inter-observer agreement and to assess the diagnostic accuracy in comparison to quantitative coronary angiography (QCA). METHODS: Fifty-three patients referred for coronary x-ray angiography were previously examined in a 3 Tesla whole-body scanner. Adenosine and rest perfusion CMR were acquired for the quantification of MPR in all segments. Two blinded and independent readers analyzed all images. QCA was performed in case of coronary stenosis. QCA data was used to assess diagnostic accuracy of the MPR measurements. RESULTS: Inter-observer agreement was high for all myocardial perfusion territories (ρ = 0.92 for LAD, ρ = 0.93 for CX and RCA perfused segments). Compared to QCA receiver-operating characteristics yielded an area under the curve of 0.78 and 0.73 for RCA, 0.66 and 0.69 for LAD, and 0.52 and 0.53 for LCX perfused territories. CONCLUSIONS: Inter-observer agreement of MPR quantification at 3 Tesla CMR is very high for all myocardial segments. Diagnostic accuracy in comparison to QCA yields good values for the RCA and LAD perfused territories, but moderate values for the posterior LCX perfused myocardial segments. BioMed Central 2013-03-27 /pmc/articles/PMC3707831/ /pubmed/23537061 http://dx.doi.org/10.1186/1532-429X-15-25 Text en Copyright © 2013 Ikuye et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Ikuye, Katharina
Buckert, Dominik
Schaaf, Lisa
Walcher, Thomas
Rottbauer, Wolfgang
Bernhardt, Peter
Inter-observer agreement and diagnostic accuracy of myocardial perfusion reserve quantification by cardiovascular magnetic resonance at 3 Tesla in comparison to quantitative coronary angiography
title Inter-observer agreement and diagnostic accuracy of myocardial perfusion reserve quantification by cardiovascular magnetic resonance at 3 Tesla in comparison to quantitative coronary angiography
title_full Inter-observer agreement and diagnostic accuracy of myocardial perfusion reserve quantification by cardiovascular magnetic resonance at 3 Tesla in comparison to quantitative coronary angiography
title_fullStr Inter-observer agreement and diagnostic accuracy of myocardial perfusion reserve quantification by cardiovascular magnetic resonance at 3 Tesla in comparison to quantitative coronary angiography
title_full_unstemmed Inter-observer agreement and diagnostic accuracy of myocardial perfusion reserve quantification by cardiovascular magnetic resonance at 3 Tesla in comparison to quantitative coronary angiography
title_short Inter-observer agreement and diagnostic accuracy of myocardial perfusion reserve quantification by cardiovascular magnetic resonance at 3 Tesla in comparison to quantitative coronary angiography
title_sort inter-observer agreement and diagnostic accuracy of myocardial perfusion reserve quantification by cardiovascular magnetic resonance at 3 tesla in comparison to quantitative coronary angiography
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3707831/
https://www.ncbi.nlm.nih.gov/pubmed/23537061
http://dx.doi.org/10.1186/1532-429X-15-25
work_keys_str_mv AT ikuyekatharina interobserveragreementanddiagnosticaccuracyofmyocardialperfusionreservequantificationbycardiovascularmagneticresonanceat3teslaincomparisontoquantitativecoronaryangiography
AT buckertdominik interobserveragreementanddiagnosticaccuracyofmyocardialperfusionreservequantificationbycardiovascularmagneticresonanceat3teslaincomparisontoquantitativecoronaryangiography
AT schaaflisa interobserveragreementanddiagnosticaccuracyofmyocardialperfusionreservequantificationbycardiovascularmagneticresonanceat3teslaincomparisontoquantitativecoronaryangiography
AT walcherthomas interobserveragreementanddiagnosticaccuracyofmyocardialperfusionreservequantificationbycardiovascularmagneticresonanceat3teslaincomparisontoquantitativecoronaryangiography
AT rottbauerwolfgang interobserveragreementanddiagnosticaccuracyofmyocardialperfusionreservequantificationbycardiovascularmagneticresonanceat3teslaincomparisontoquantitativecoronaryangiography
AT bernhardtpeter interobserveragreementanddiagnosticaccuracyofmyocardialperfusionreservequantificationbycardiovascularmagneticresonanceat3teslaincomparisontoquantitativecoronaryangiography