Cargando…
High resolution (3 Tesla) MRI-guided conformal brachytherapy for cervical cancer: consequences of different high-risk CTV sizes
PURPOSE: To evaluate conventional brachytherapy (BT) plans using dose-volume parameters and high resolution (3 Tesla) MRI datasets, and to quantify dosimetric benefits and limitations when MRI-guided, conformal BT (MRIG-CBT) plans are generated. MATERIAL AND METHODS: Fifty-five clinical high-dose-ra...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Termedia Publishing House
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3708151/ https://www.ncbi.nlm.nih.gov/pubmed/23878555 http://dx.doi.org/10.5114/jcb.2013.36180 |
_version_ | 1782276589261684736 |
---|---|
author | Anderson, James W. Xia, Junyi Flynn, Ryan T. Modrick, Joseph M. Bhatia, Sudershan K. Jacobson, Geraldine M. Kim, Yusung |
author_facet | Anderson, James W. Xia, Junyi Flynn, Ryan T. Modrick, Joseph M. Bhatia, Sudershan K. Jacobson, Geraldine M. Kim, Yusung |
author_sort | Anderson, James W. |
collection | PubMed |
description | PURPOSE: To evaluate conventional brachytherapy (BT) plans using dose-volume parameters and high resolution (3 Tesla) MRI datasets, and to quantify dosimetric benefits and limitations when MRI-guided, conformal BT (MRIG-CBT) plans are generated. MATERIAL AND METHODS: Fifty-five clinical high-dose-rate BT plans from 14 cervical cancer patients were retrospectively studied. All conventional plans were created using MRI with titanium tandem-and-ovoid applicator (T&O) for delivery. For each conventional plan, a MRIG-CBT plan was retrospectively generated using hybrid inverse optimization. Three categories of high risk (HR)-CTV were considered based on volume: non-bulky (< 2(0 cc)), low-bulky (> 20 cc and < 40 cc) and bulky (≥ 40 cc). Dose-volume metrics of D(90) of HR-CTV and D(2cc) and D(0.1cc) of rectum, bladder, and sigmoid colon were analyzed. RESULTS: Tumor coverage (HR-CTV D(90)) of the conventional plans was considerably affected by the HR-CTV size. Sixteen percent of the plans covered HR-CTV D(90) with the prescription dose within 5%. At least one OAR had D(2cc) values over the GEC-ESTRO recommended limits in 52.7% of the conventional plans. MRIG-CBT plans showed improved target coverage for HR-CTV D(90) of 98 and 97% of the prescribed dose for non-bulky and low-bulky tumors, respectively. No MRIG-CBT plans surpassed the D(2cc) limits of any OAR. Only small improvements (D(90) of 80%) were found for large targets (> 40 cc) when using T&O applicator approach. CONCLUSIONS: MRIG-CBT plans displayed considerable improvement for tumor coverage and OAR sparing over conventional treatment. When the HR-CTV volume exceeded 40 cc, its improvements were diminished when using a conventional intracavitary applicator. |
format | Online Article Text |
id | pubmed-3708151 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Termedia Publishing House |
record_format | MEDLINE/PubMed |
spelling | pubmed-37081512013-07-22 High resolution (3 Tesla) MRI-guided conformal brachytherapy for cervical cancer: consequences of different high-risk CTV sizes Anderson, James W. Xia, Junyi Flynn, Ryan T. Modrick, Joseph M. Bhatia, Sudershan K. Jacobson, Geraldine M. Kim, Yusung J Contemp Brachytherapy Original Paper PURPOSE: To evaluate conventional brachytherapy (BT) plans using dose-volume parameters and high resolution (3 Tesla) MRI datasets, and to quantify dosimetric benefits and limitations when MRI-guided, conformal BT (MRIG-CBT) plans are generated. MATERIAL AND METHODS: Fifty-five clinical high-dose-rate BT plans from 14 cervical cancer patients were retrospectively studied. All conventional plans were created using MRI with titanium tandem-and-ovoid applicator (T&O) for delivery. For each conventional plan, a MRIG-CBT plan was retrospectively generated using hybrid inverse optimization. Three categories of high risk (HR)-CTV were considered based on volume: non-bulky (< 2(0 cc)), low-bulky (> 20 cc and < 40 cc) and bulky (≥ 40 cc). Dose-volume metrics of D(90) of HR-CTV and D(2cc) and D(0.1cc) of rectum, bladder, and sigmoid colon were analyzed. RESULTS: Tumor coverage (HR-CTV D(90)) of the conventional plans was considerably affected by the HR-CTV size. Sixteen percent of the plans covered HR-CTV D(90) with the prescription dose within 5%. At least one OAR had D(2cc) values over the GEC-ESTRO recommended limits in 52.7% of the conventional plans. MRIG-CBT plans showed improved target coverage for HR-CTV D(90) of 98 and 97% of the prescribed dose for non-bulky and low-bulky tumors, respectively. No MRIG-CBT plans surpassed the D(2cc) limits of any OAR. Only small improvements (D(90) of 80%) were found for large targets (> 40 cc) when using T&O applicator approach. CONCLUSIONS: MRIG-CBT plans displayed considerable improvement for tumor coverage and OAR sparing over conventional treatment. When the HR-CTV volume exceeded 40 cc, its improvements were diminished when using a conventional intracavitary applicator. Termedia Publishing House 2013-06-28 2013-06 /pmc/articles/PMC3708151/ /pubmed/23878555 http://dx.doi.org/10.5114/jcb.2013.36180 Text en Copyright © 2013 Termedia http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Paper Anderson, James W. Xia, Junyi Flynn, Ryan T. Modrick, Joseph M. Bhatia, Sudershan K. Jacobson, Geraldine M. Kim, Yusung High resolution (3 Tesla) MRI-guided conformal brachytherapy for cervical cancer: consequences of different high-risk CTV sizes |
title | High resolution (3 Tesla) MRI-guided conformal brachytherapy for cervical cancer: consequences of different high-risk CTV sizes |
title_full | High resolution (3 Tesla) MRI-guided conformal brachytherapy for cervical cancer: consequences of different high-risk CTV sizes |
title_fullStr | High resolution (3 Tesla) MRI-guided conformal brachytherapy for cervical cancer: consequences of different high-risk CTV sizes |
title_full_unstemmed | High resolution (3 Tesla) MRI-guided conformal brachytherapy for cervical cancer: consequences of different high-risk CTV sizes |
title_short | High resolution (3 Tesla) MRI-guided conformal brachytherapy for cervical cancer: consequences of different high-risk CTV sizes |
title_sort | high resolution (3 tesla) mri-guided conformal brachytherapy for cervical cancer: consequences of different high-risk ctv sizes |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3708151/ https://www.ncbi.nlm.nih.gov/pubmed/23878555 http://dx.doi.org/10.5114/jcb.2013.36180 |
work_keys_str_mv | AT andersonjamesw highresolution3teslamriguidedconformalbrachytherapyforcervicalcancerconsequencesofdifferenthighriskctvsizes AT xiajunyi highresolution3teslamriguidedconformalbrachytherapyforcervicalcancerconsequencesofdifferenthighriskctvsizes AT flynnryant highresolution3teslamriguidedconformalbrachytherapyforcervicalcancerconsequencesofdifferenthighriskctvsizes AT modrickjosephm highresolution3teslamriguidedconformalbrachytherapyforcervicalcancerconsequencesofdifferenthighriskctvsizes AT bhatiasudershank highresolution3teslamriguidedconformalbrachytherapyforcervicalcancerconsequencesofdifferenthighriskctvsizes AT jacobsongeraldinem highresolution3teslamriguidedconformalbrachytherapyforcervicalcancerconsequencesofdifferenthighriskctvsizes AT kimyusung highresolution3teslamriguidedconformalbrachytherapyforcervicalcancerconsequencesofdifferenthighriskctvsizes |