Usefulness of Infrared Thermal Imaging Camera for Screening of Postoperative Surgical Site Infection after the Nuss Procedure

Introduction and Objective. The Nuss procedure is widely used in the treatment of pectus excavatum worldwide. Postoperative pectus bar infection is one of the most serious complications associated with this procedure. Therefore, early detection of signs of implant infection is very important. Howeve...

Descripción completa

Detalles Bibliográficos
Autores principales: Fujita, Kenya, Noguchi, Masahiko, Yuzuriha, Shunsuke, Yanagisawa, Daisuke, Matsuo, Kiyoshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3708438/
https://www.ncbi.nlm.nih.gov/pubmed/23878757
http://dx.doi.org/10.1155/2013/946156
_version_ 1782276620631932928
author Fujita, Kenya
Noguchi, Masahiko
Yuzuriha, Shunsuke
Yanagisawa, Daisuke
Matsuo, Kiyoshi
author_facet Fujita, Kenya
Noguchi, Masahiko
Yuzuriha, Shunsuke
Yanagisawa, Daisuke
Matsuo, Kiyoshi
author_sort Fujita, Kenya
collection PubMed
description Introduction and Objective. The Nuss procedure is widely used in the treatment of pectus excavatum worldwide. Postoperative pectus bar infection is one of the most serious complications associated with this procedure. Therefore, early detection of signs of implant infection is very important. However, this is difficult, and effective methods have yet to be established. Methods. We use a handheld infrared thermal imaging camera to screen patients for postoperative infection following the Nuss procedure. Here, we report a 28-year-old man with recurrent postoperative (Ravitch procedure) pectus excavatum. Results. Infrared thermography camera clearly indicated slight cellulitis in the right chest. Conclusion. Our technique may assist in preventing postoperative bar infection and removal caused by severe bar infection. Furthermore, this camera is potentially suitable for many situations in infection monitoring following subcutaneous implant surgery.
format Online
Article
Text
id pubmed-3708438
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-37084382013-07-22 Usefulness of Infrared Thermal Imaging Camera for Screening of Postoperative Surgical Site Infection after the Nuss Procedure Fujita, Kenya Noguchi, Masahiko Yuzuriha, Shunsuke Yanagisawa, Daisuke Matsuo, Kiyoshi Case Rep Surg Case Report Introduction and Objective. The Nuss procedure is widely used in the treatment of pectus excavatum worldwide. Postoperative pectus bar infection is one of the most serious complications associated with this procedure. Therefore, early detection of signs of implant infection is very important. However, this is difficult, and effective methods have yet to be established. Methods. We use a handheld infrared thermal imaging camera to screen patients for postoperative infection following the Nuss procedure. Here, we report a 28-year-old man with recurrent postoperative (Ravitch procedure) pectus excavatum. Results. Infrared thermography camera clearly indicated slight cellulitis in the right chest. Conclusion. Our technique may assist in preventing postoperative bar infection and removal caused by severe bar infection. Furthermore, this camera is potentially suitable for many situations in infection monitoring following subcutaneous implant surgery. Hindawi Publishing Corporation 2013 2013-06-25 /pmc/articles/PMC3708438/ /pubmed/23878757 http://dx.doi.org/10.1155/2013/946156 Text en Copyright © 2013 Kenya Fujita et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Fujita, Kenya
Noguchi, Masahiko
Yuzuriha, Shunsuke
Yanagisawa, Daisuke
Matsuo, Kiyoshi
Usefulness of Infrared Thermal Imaging Camera for Screening of Postoperative Surgical Site Infection after the Nuss Procedure
title Usefulness of Infrared Thermal Imaging Camera for Screening of Postoperative Surgical Site Infection after the Nuss Procedure
title_full Usefulness of Infrared Thermal Imaging Camera for Screening of Postoperative Surgical Site Infection after the Nuss Procedure
title_fullStr Usefulness of Infrared Thermal Imaging Camera for Screening of Postoperative Surgical Site Infection after the Nuss Procedure
title_full_unstemmed Usefulness of Infrared Thermal Imaging Camera for Screening of Postoperative Surgical Site Infection after the Nuss Procedure
title_short Usefulness of Infrared Thermal Imaging Camera for Screening of Postoperative Surgical Site Infection after the Nuss Procedure
title_sort usefulness of infrared thermal imaging camera for screening of postoperative surgical site infection after the nuss procedure
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3708438/
https://www.ncbi.nlm.nih.gov/pubmed/23878757
http://dx.doi.org/10.1155/2013/946156
work_keys_str_mv AT fujitakenya usefulnessofinfraredthermalimagingcameraforscreeningofpostoperativesurgicalsiteinfectionafterthenussprocedure
AT noguchimasahiko usefulnessofinfraredthermalimagingcameraforscreeningofpostoperativesurgicalsiteinfectionafterthenussprocedure
AT yuzurihashunsuke usefulnessofinfraredthermalimagingcameraforscreeningofpostoperativesurgicalsiteinfectionafterthenussprocedure
AT yanagisawadaisuke usefulnessofinfraredthermalimagingcameraforscreeningofpostoperativesurgicalsiteinfectionafterthenussprocedure
AT matsuokiyoshi usefulnessofinfraredthermalimagingcameraforscreeningofpostoperativesurgicalsiteinfectionafterthenussprocedure