SPICE-NIRS Microbeam: a focused vertical system for proton irradiation of a single cell for radiobiological research

The Single Particle Irradiation system to Cell (SPICE) facility at the National Institute of Radiological Sciences (NIRS) is a focused vertical microbeam system designed to irradiate the nuclei of adhesive mammalian cells with a defined number of 3.4 MeV protons. The approximately 2-μm diameter prot...

Descripción completa

Detalles Bibliográficos
Autores principales: Konishi, Teruaki, Oikawa, Masakazu, Suya, Noriyoshi, Ishikawa, Takahiro, Maeda, Takeshi, Kobayashi, Alisa, Shiomi, Naoko, Kodama, Kumiko, Hamano, Tsuyoshi, Homma-Takeda, Shino, Isono, Mayu, Hieda, Kotaro, Uchihori, Yukio, Shirakawa, Yoshiyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3709661/
https://www.ncbi.nlm.nih.gov/pubmed/23287773
http://dx.doi.org/10.1093/jrr/rrs132
_version_ 1782276776940011520
author Konishi, Teruaki
Oikawa, Masakazu
Suya, Noriyoshi
Ishikawa, Takahiro
Maeda, Takeshi
Kobayashi, Alisa
Shiomi, Naoko
Kodama, Kumiko
Hamano, Tsuyoshi
Homma-Takeda, Shino
Isono, Mayu
Hieda, Kotaro
Uchihori, Yukio
Shirakawa, Yoshiyuki
author_facet Konishi, Teruaki
Oikawa, Masakazu
Suya, Noriyoshi
Ishikawa, Takahiro
Maeda, Takeshi
Kobayashi, Alisa
Shiomi, Naoko
Kodama, Kumiko
Hamano, Tsuyoshi
Homma-Takeda, Shino
Isono, Mayu
Hieda, Kotaro
Uchihori, Yukio
Shirakawa, Yoshiyuki
author_sort Konishi, Teruaki
collection PubMed
description The Single Particle Irradiation system to Cell (SPICE) facility at the National Institute of Radiological Sciences (NIRS) is a focused vertical microbeam system designed to irradiate the nuclei of adhesive mammalian cells with a defined number of 3.4 MeV protons. The approximately 2-μm diameter proton beam is focused with a magnetic quadrupole triplet lens and traverses the cells contained in dishes from bottom to top. All procedures for irradiation, such as cell image capturing, cell recognition and position calculation, are automated. The most distinctive characteristic of the system is its stability and high throughput; i.e. 3000 cells in a 5 mm × 5 mm area in a single dish can be routinely irradiated by the 2-μm beam within 15 min (the maximum irradiation speed is 400 cells/min). The number of protons can be set as low as one, at a precision measured by CR-39 detectors to be 99.0%. A variety of targeting modes such as fractional population targeting mode, multi-position targeting mode for nucleus irradiation and cytoplasm targeting mode are available. As an example of multi-position targeting irradiation of mammalian cells, five fluorescent spots in a cell nucleus were demonstrated using the γ-H2AX immune-staining technique. The SPICE performance modes described in this paper are in routine use. SPICE is a joint-use research facility of NIRS and its beam times are distributed for collaborative research.
format Online
Article
Text
id pubmed-3709661
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-37096612013-07-15 SPICE-NIRS Microbeam: a focused vertical system for proton irradiation of a single cell for radiobiological research Konishi, Teruaki Oikawa, Masakazu Suya, Noriyoshi Ishikawa, Takahiro Maeda, Takeshi Kobayashi, Alisa Shiomi, Naoko Kodama, Kumiko Hamano, Tsuyoshi Homma-Takeda, Shino Isono, Mayu Hieda, Kotaro Uchihori, Yukio Shirakawa, Yoshiyuki J Radiat Res Technology The Single Particle Irradiation system to Cell (SPICE) facility at the National Institute of Radiological Sciences (NIRS) is a focused vertical microbeam system designed to irradiate the nuclei of adhesive mammalian cells with a defined number of 3.4 MeV protons. The approximately 2-μm diameter proton beam is focused with a magnetic quadrupole triplet lens and traverses the cells contained in dishes from bottom to top. All procedures for irradiation, such as cell image capturing, cell recognition and position calculation, are automated. The most distinctive characteristic of the system is its stability and high throughput; i.e. 3000 cells in a 5 mm × 5 mm area in a single dish can be routinely irradiated by the 2-μm beam within 15 min (the maximum irradiation speed is 400 cells/min). The number of protons can be set as low as one, at a precision measured by CR-39 detectors to be 99.0%. A variety of targeting modes such as fractional population targeting mode, multi-position targeting mode for nucleus irradiation and cytoplasm targeting mode are available. As an example of multi-position targeting irradiation of mammalian cells, five fluorescent spots in a cell nucleus were demonstrated using the γ-H2AX immune-staining technique. The SPICE performance modes described in this paper are in routine use. SPICE is a joint-use research facility of NIRS and its beam times are distributed for collaborative research. Oxford University Press 2013-07 2013-01-03 /pmc/articles/PMC3709661/ /pubmed/23287773 http://dx.doi.org/10.1093/jrr/rrs132 Text en © The Author 2013. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Therapeutic Radiology and Oncology. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technology
Konishi, Teruaki
Oikawa, Masakazu
Suya, Noriyoshi
Ishikawa, Takahiro
Maeda, Takeshi
Kobayashi, Alisa
Shiomi, Naoko
Kodama, Kumiko
Hamano, Tsuyoshi
Homma-Takeda, Shino
Isono, Mayu
Hieda, Kotaro
Uchihori, Yukio
Shirakawa, Yoshiyuki
SPICE-NIRS Microbeam: a focused vertical system for proton irradiation of a single cell for radiobiological research
title SPICE-NIRS Microbeam: a focused vertical system for proton irradiation of a single cell for radiobiological research
title_full SPICE-NIRS Microbeam: a focused vertical system for proton irradiation of a single cell for radiobiological research
title_fullStr SPICE-NIRS Microbeam: a focused vertical system for proton irradiation of a single cell for radiobiological research
title_full_unstemmed SPICE-NIRS Microbeam: a focused vertical system for proton irradiation of a single cell for radiobiological research
title_short SPICE-NIRS Microbeam: a focused vertical system for proton irradiation of a single cell for radiobiological research
title_sort spice-nirs microbeam: a focused vertical system for proton irradiation of a single cell for radiobiological research
topic Technology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3709661/
https://www.ncbi.nlm.nih.gov/pubmed/23287773
http://dx.doi.org/10.1093/jrr/rrs132
work_keys_str_mv AT konishiteruaki spicenirsmicrobeamafocusedverticalsystemforprotonirradiationofasinglecellforradiobiologicalresearch
AT oikawamasakazu spicenirsmicrobeamafocusedverticalsystemforprotonirradiationofasinglecellforradiobiologicalresearch
AT suyanoriyoshi spicenirsmicrobeamafocusedverticalsystemforprotonirradiationofasinglecellforradiobiologicalresearch
AT ishikawatakahiro spicenirsmicrobeamafocusedverticalsystemforprotonirradiationofasinglecellforradiobiologicalresearch
AT maedatakeshi spicenirsmicrobeamafocusedverticalsystemforprotonirradiationofasinglecellforradiobiologicalresearch
AT kobayashialisa spicenirsmicrobeamafocusedverticalsystemforprotonirradiationofasinglecellforradiobiologicalresearch
AT shiominaoko spicenirsmicrobeamafocusedverticalsystemforprotonirradiationofasinglecellforradiobiologicalresearch
AT kodamakumiko spicenirsmicrobeamafocusedverticalsystemforprotonirradiationofasinglecellforradiobiologicalresearch
AT hamanotsuyoshi spicenirsmicrobeamafocusedverticalsystemforprotonirradiationofasinglecellforradiobiologicalresearch
AT hommatakedashino spicenirsmicrobeamafocusedverticalsystemforprotonirradiationofasinglecellforradiobiologicalresearch
AT isonomayu spicenirsmicrobeamafocusedverticalsystemforprotonirradiationofasinglecellforradiobiologicalresearch
AT hiedakotaro spicenirsmicrobeamafocusedverticalsystemforprotonirradiationofasinglecellforradiobiologicalresearch
AT uchihoriyukio spicenirsmicrobeamafocusedverticalsystemforprotonirradiationofasinglecellforradiobiologicalresearch
AT shirakawayoshiyuki spicenirsmicrobeamafocusedverticalsystemforprotonirradiationofasinglecellforradiobiologicalresearch