Motor Weakness after Caudal Epidural Injection Using the Air-acceptance Test
Air injected into the epidural space may spread along the nerves of the paravertebral space. Depending on the location of the air, neurologic complications such as multiradicular syndrome, lumbar root compression, and even paraplegia may occur. However, cases of motor weakness caused by air bubbles...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Pain Society
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3710943/ https://www.ncbi.nlm.nih.gov/pubmed/23862003 http://dx.doi.org/10.3344/kjp.2013.26.3.286 |
_version_ | 1782276911590801408 |
---|---|
author | Lee, Mi Hyeon Han, Cheol Sig Lee, Sang Hoon Lee, Jeong Hyun Choi, Eun Mi Choi, Young Ryong Chung, Mi Hwa |
author_facet | Lee, Mi Hyeon Han, Cheol Sig Lee, Sang Hoon Lee, Jeong Hyun Choi, Eun Mi Choi, Young Ryong Chung, Mi Hwa |
author_sort | Lee, Mi Hyeon |
collection | PubMed |
description | Air injected into the epidural space may spread along the nerves of the paravertebral space. Depending on the location of the air, neurologic complications such as multiradicular syndrome, lumbar root compression, and even paraplegia may occur. However, cases of motor weakness caused by air bubbles after caudal epidural injection are rare. A 44-year-old female patient received a caudal epidural injection after an air-acceptance test. Four hours later, she complained of motor weakness in the right lower extremity and numbness of the S1 dermatome. Magnetic resonance imaging showed no anomalies other than an air bubble measuring 13 mm in length and 0.337 ml in volume positioned near the right S1 root. Her symptoms completely regressed within 48 hours. |
format | Online Article Text |
id | pubmed-3710943 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | The Korean Pain Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-37109432013-07-16 Motor Weakness after Caudal Epidural Injection Using the Air-acceptance Test Lee, Mi Hyeon Han, Cheol Sig Lee, Sang Hoon Lee, Jeong Hyun Choi, Eun Mi Choi, Young Ryong Chung, Mi Hwa Korean J Pain Case Report Air injected into the epidural space may spread along the nerves of the paravertebral space. Depending on the location of the air, neurologic complications such as multiradicular syndrome, lumbar root compression, and even paraplegia may occur. However, cases of motor weakness caused by air bubbles after caudal epidural injection are rare. A 44-year-old female patient received a caudal epidural injection after an air-acceptance test. Four hours later, she complained of motor weakness in the right lower extremity and numbness of the S1 dermatome. Magnetic resonance imaging showed no anomalies other than an air bubble measuring 13 mm in length and 0.337 ml in volume positioned near the right S1 root. Her symptoms completely regressed within 48 hours. The Korean Pain Society 2013-07 2013-07-01 /pmc/articles/PMC3710943/ /pubmed/23862003 http://dx.doi.org/10.3344/kjp.2013.26.3.286 Text en Copyright © The Korean Pain Society, 2013 http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Lee, Mi Hyeon Han, Cheol Sig Lee, Sang Hoon Lee, Jeong Hyun Choi, Eun Mi Choi, Young Ryong Chung, Mi Hwa Motor Weakness after Caudal Epidural Injection Using the Air-acceptance Test |
title | Motor Weakness after Caudal Epidural Injection Using the Air-acceptance Test |
title_full | Motor Weakness after Caudal Epidural Injection Using the Air-acceptance Test |
title_fullStr | Motor Weakness after Caudal Epidural Injection Using the Air-acceptance Test |
title_full_unstemmed | Motor Weakness after Caudal Epidural Injection Using the Air-acceptance Test |
title_short | Motor Weakness after Caudal Epidural Injection Using the Air-acceptance Test |
title_sort | motor weakness after caudal epidural injection using the air-acceptance test |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3710943/ https://www.ncbi.nlm.nih.gov/pubmed/23862003 http://dx.doi.org/10.3344/kjp.2013.26.3.286 |
work_keys_str_mv | AT leemihyeon motorweaknessaftercaudalepiduralinjectionusingtheairacceptancetest AT hancheolsig motorweaknessaftercaudalepiduralinjectionusingtheairacceptancetest AT leesanghoon motorweaknessaftercaudalepiduralinjectionusingtheairacceptancetest AT leejeonghyun motorweaknessaftercaudalepiduralinjectionusingtheairacceptancetest AT choieunmi motorweaknessaftercaudalepiduralinjectionusingtheairacceptancetest AT choiyoungryong motorweaknessaftercaudalepiduralinjectionusingtheairacceptancetest AT chungmihwa motorweaknessaftercaudalepiduralinjectionusingtheairacceptancetest |