Cargando…

Comparison of hemodynamic response to tracheal intubation with Macintosh and McCoy laryngoscopes

BACKGROUND: Use of McCoy blade laryngoscope avoids the lifting force in the vallecula and theoretically should lead to a lower hemodynamic response related to laryngoscopy and tracheal intubation. The available literature on the topic is conflicting. MATERIALS AND METHODS: We studied the hemodynamic...

Descripción completa

Detalles Bibliográficos
Autores principales: Haidry, Mehtab A, Khan, Fauzia A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3713667/
https://www.ncbi.nlm.nih.gov/pubmed/23878441
http://dx.doi.org/10.4103/0970-9185.111710
_version_ 1782277219743170560
author Haidry, Mehtab A
Khan, Fauzia A
author_facet Haidry, Mehtab A
Khan, Fauzia A
author_sort Haidry, Mehtab A
collection PubMed
description BACKGROUND: Use of McCoy blade laryngoscope avoids the lifting force in the vallecula and theoretically should lead to a lower hemodynamic response related to laryngoscopy and tracheal intubation. The available literature on the topic is conflicting. MATERIALS AND METHODS: We studied the hemodynamic response to laryngoscopy and tracheal intubation in 60 ASA 1 AND 2 adult patients using either Macintosh or McCoy laryngoscopes. The change in systolic, diastolic, mean arterial pressure, and heart rate (HR) was observed for 10 min post intubation. Arrhythmias and ST changes were also observed. RESULTS: The maximum change in HR was 18.7% in the Macintosh and 7.7% in the McCoy group, and in systolic arterial pressure was 22.9% in the Macintosh and 10.3% in the McCoy group. This difference between groups was significant (P < 0.0001). The change lasted for a lesser duration in the McCoy group. No arrhythmias or ST changes were observed in either group. CONCLUSION: Hemodynamic changes with use of McCoy laryngoscope were lesser in magnitude and of shorter duration.
format Online
Article
Text
id pubmed-3713667
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-37136672013-07-22 Comparison of hemodynamic response to tracheal intubation with Macintosh and McCoy laryngoscopes Haidry, Mehtab A Khan, Fauzia A J Anaesthesiol Clin Pharmacol Original Article BACKGROUND: Use of McCoy blade laryngoscope avoids the lifting force in the vallecula and theoretically should lead to a lower hemodynamic response related to laryngoscopy and tracheal intubation. The available literature on the topic is conflicting. MATERIALS AND METHODS: We studied the hemodynamic response to laryngoscopy and tracheal intubation in 60 ASA 1 AND 2 adult patients using either Macintosh or McCoy laryngoscopes. The change in systolic, diastolic, mean arterial pressure, and heart rate (HR) was observed for 10 min post intubation. Arrhythmias and ST changes were also observed. RESULTS: The maximum change in HR was 18.7% in the Macintosh and 7.7% in the McCoy group, and in systolic arterial pressure was 22.9% in the Macintosh and 10.3% in the McCoy group. This difference between groups was significant (P < 0.0001). The change lasted for a lesser duration in the McCoy group. No arrhythmias or ST changes were observed in either group. CONCLUSION: Hemodynamic changes with use of McCoy laryngoscope were lesser in magnitude and of shorter duration. Medknow Publications & Media Pvt Ltd 2013 /pmc/articles/PMC3713667/ /pubmed/23878441 http://dx.doi.org/10.4103/0970-9185.111710 Text en Copyright: © Journal of Anaesthesiology Clinical Pharmacology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Haidry, Mehtab A
Khan, Fauzia A
Comparison of hemodynamic response to tracheal intubation with Macintosh and McCoy laryngoscopes
title Comparison of hemodynamic response to tracheal intubation with Macintosh and McCoy laryngoscopes
title_full Comparison of hemodynamic response to tracheal intubation with Macintosh and McCoy laryngoscopes
title_fullStr Comparison of hemodynamic response to tracheal intubation with Macintosh and McCoy laryngoscopes
title_full_unstemmed Comparison of hemodynamic response to tracheal intubation with Macintosh and McCoy laryngoscopes
title_short Comparison of hemodynamic response to tracheal intubation with Macintosh and McCoy laryngoscopes
title_sort comparison of hemodynamic response to tracheal intubation with macintosh and mccoy laryngoscopes
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3713667/
https://www.ncbi.nlm.nih.gov/pubmed/23878441
http://dx.doi.org/10.4103/0970-9185.111710
work_keys_str_mv AT haidrymehtaba comparisonofhemodynamicresponsetotrachealintubationwithmacintoshandmccoylaryngoscopes
AT khanfauziaa comparisonofhemodynamicresponsetotrachealintubationwithmacintoshandmccoylaryngoscopes