Cargando…

Flow-Injection Coulometric Detection Based on Ion Transfer and Its Application to the Determination of Chlorpromazine

A flow-injection coulometric method for the determination of chlorpromazine based on ion transfer into a plasticized poly(vinyl chloride) (PVC) membrane, was developed. The detector used consists of a flow-through cell that incorporates a plasticized poly(vinyl chloride) (PVC) membrane which contain...

Descripción completa

Detalles Bibliográficos
Autores principales: Ortuño, Joaquín A., Gil, Antonio, Sánchez-Pedreño, Concepción
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3714659/
https://www.ncbi.nlm.nih.gov/pubmed/27879901
http://dx.doi.org/10.3390/s8063678
_version_ 1782277388933005312
author Ortuño, Joaquín A.
Gil, Antonio
Sánchez-Pedreño, Concepción
author_facet Ortuño, Joaquín A.
Gil, Antonio
Sánchez-Pedreño, Concepción
author_sort Ortuño, Joaquín A.
collection PubMed
description A flow-injection coulometric method for the determination of chlorpromazine based on ion transfer into a plasticized poly(vinyl chloride) (PVC) membrane, was developed. The detector used consists of a flow-through cell that incorporates a plasticized poly(vinyl chloride) (PVC) membrane which contains tetrabutylammonium tetraphenylborate as electrolyte. The membrane is located between the flowing solution and an inner aqueous electrolyte solution. Two pairs of electrodes, each pair formed by a reference electrode and a working electrode, are used, one pair in each solution. The potential between the reference electrodes was controlled by a four-electrode potentiostat with ohmic drop compensation. A potential step capable of producing the transfer of the chlorpromazine ion into the membrane was applied during the passage of a wide portion of sample plug through the cell and the corresponding quantity of the electricity was measured. In the selected conditions, a linear relationship was observed between the quantity of electricity and chlorpromazine concentrations over a range of 1×10(-6) −1×10(-4) M. The detection limit was 2 × 10(-7) M. Good repeatability and between-day reproducibility was obtained. No interference was observed on the part of some common ions and pharmaceutical excipients. The method proposed was applied satisfactorily to the determination of chlorpromazine in pharmaceuticals and human urine.
format Online
Article
Text
id pubmed-3714659
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-37146592013-07-18 Flow-Injection Coulometric Detection Based on Ion Transfer and Its Application to the Determination of Chlorpromazine Ortuño, Joaquín A. Gil, Antonio Sánchez-Pedreño, Concepción Sensors (Basel) Article A flow-injection coulometric method for the determination of chlorpromazine based on ion transfer into a plasticized poly(vinyl chloride) (PVC) membrane, was developed. The detector used consists of a flow-through cell that incorporates a plasticized poly(vinyl chloride) (PVC) membrane which contains tetrabutylammonium tetraphenylborate as electrolyte. The membrane is located between the flowing solution and an inner aqueous electrolyte solution. Two pairs of electrodes, each pair formed by a reference electrode and a working electrode, are used, one pair in each solution. The potential between the reference electrodes was controlled by a four-electrode potentiostat with ohmic drop compensation. A potential step capable of producing the transfer of the chlorpromazine ion into the membrane was applied during the passage of a wide portion of sample plug through the cell and the corresponding quantity of the electricity was measured. In the selected conditions, a linear relationship was observed between the quantity of electricity and chlorpromazine concentrations over a range of 1×10(-6) −1×10(-4) M. The detection limit was 2 × 10(-7) M. Good repeatability and between-day reproducibility was obtained. No interference was observed on the part of some common ions and pharmaceutical excipients. The method proposed was applied satisfactorily to the determination of chlorpromazine in pharmaceuticals and human urine. Molecular Diversity Preservation International (MDPI) 2008-06-01 /pmc/articles/PMC3714659/ /pubmed/27879901 http://dx.doi.org/10.3390/s8063678 Text en © 2008 by the authors; licensee Molecular Diversity Preservation International, Basel, Switzerland. This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Ortuño, Joaquín A.
Gil, Antonio
Sánchez-Pedreño, Concepción
Flow-Injection Coulometric Detection Based on Ion Transfer and Its Application to the Determination of Chlorpromazine
title Flow-Injection Coulometric Detection Based on Ion Transfer and Its Application to the Determination of Chlorpromazine
title_full Flow-Injection Coulometric Detection Based on Ion Transfer and Its Application to the Determination of Chlorpromazine
title_fullStr Flow-Injection Coulometric Detection Based on Ion Transfer and Its Application to the Determination of Chlorpromazine
title_full_unstemmed Flow-Injection Coulometric Detection Based on Ion Transfer and Its Application to the Determination of Chlorpromazine
title_short Flow-Injection Coulometric Detection Based on Ion Transfer and Its Application to the Determination of Chlorpromazine
title_sort flow-injection coulometric detection based on ion transfer and its application to the determination of chlorpromazine
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3714659/
https://www.ncbi.nlm.nih.gov/pubmed/27879901
http://dx.doi.org/10.3390/s8063678
work_keys_str_mv AT ortunojoaquina flowinjectioncoulometricdetectionbasedoniontransferanditsapplicationtothedeterminationofchlorpromazine
AT gilantonio flowinjectioncoulometricdetectionbasedoniontransferanditsapplicationtothedeterminationofchlorpromazine
AT sanchezpedrenoconcepcion flowinjectioncoulometricdetectionbasedoniontransferanditsapplicationtothedeterminationofchlorpromazine