Biomechanical analysis of the acetabular buttress-plate: are complex acetabular fractures in the quadrilateral area stable after treatment with anterior construct plate-1/3 tube buttress plate fixation?

OBJECTIVE: The acetabular buttress-plate has been widely used in treating difficult cases with satisfying clinical results. However, the biomechanical properties of a postoperative acetabular fracture fixed by the buttress-plate are not clear. The purpose of this study was to evaluate the biomechani...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Yong-De, Cai, Xian-Hua, Liu, Xi-Ming, Zhang, Hong-Xi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3714991/
https://www.ncbi.nlm.nih.gov/pubmed/23917670
http://dx.doi.org/10.6061/clinics/2013(07)22
_version_ 1782277409215610880
author Wu, Yong-De
Cai, Xian-Hua
Liu, Xi-Ming
Zhang, Hong-Xi
author_facet Wu, Yong-De
Cai, Xian-Hua
Liu, Xi-Ming
Zhang, Hong-Xi
author_sort Wu, Yong-De
collection PubMed
description OBJECTIVE: The acetabular buttress-plate has been widely used in treating difficult cases with satisfying clinical results. However, the biomechanical properties of a postoperative acetabular fracture fixed by the buttress-plate are not clear. The purpose of this study was to evaluate the biomechanical properties of stability after the anterior tube buttress-plate fixation of complex acetabular fractures in the quadrilateral area. METHODS: A construct was proposed based on anterior construct plate - 1/3 tube buttress plate fixation for acetabular both-column fractures. Two groups of six formalin-preserved cadaveric pelvises were analyzed: (1) group A, the normal pelvis and (2) group B, anterior construct plate-1/3 tube buttress plate with quadrilateral area fixation. The displacements were measured, and cyclical loads were applied in both standing and sitting simulations. RESULTS: As the load was added, the displacements were A<B, increasing in line. In the 600 N physiological loading, the differences were significant (standing position: p = 0.013; sitting position: p = 0.009) between groups A and B. CONCLUSION: The anterior construct plate - 1/3 tube buttress plate fixation provided a better stable construct for early sitting. The standing mode yielded more significant differences between the groups. Placing a 1/3 tube buttress-plate via an anterior approach is a novel method of providing quadrilateral area support in this setting.
format Online
Article
Text
id pubmed-3714991
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo
record_format MEDLINE/PubMed
spelling pubmed-37149912013-07-22 Biomechanical analysis of the acetabular buttress-plate: are complex acetabular fractures in the quadrilateral area stable after treatment with anterior construct plate-1/3 tube buttress plate fixation? Wu, Yong-De Cai, Xian-Hua Liu, Xi-Ming Zhang, Hong-Xi Clinics (Sao Paulo) Basic Research OBJECTIVE: The acetabular buttress-plate has been widely used in treating difficult cases with satisfying clinical results. However, the biomechanical properties of a postoperative acetabular fracture fixed by the buttress-plate are not clear. The purpose of this study was to evaluate the biomechanical properties of stability after the anterior tube buttress-plate fixation of complex acetabular fractures in the quadrilateral area. METHODS: A construct was proposed based on anterior construct plate - 1/3 tube buttress plate fixation for acetabular both-column fractures. Two groups of six formalin-preserved cadaveric pelvises were analyzed: (1) group A, the normal pelvis and (2) group B, anterior construct plate-1/3 tube buttress plate with quadrilateral area fixation. The displacements were measured, and cyclical loads were applied in both standing and sitting simulations. RESULTS: As the load was added, the displacements were A<B, increasing in line. In the 600 N physiological loading, the differences were significant (standing position: p = 0.013; sitting position: p = 0.009) between groups A and B. CONCLUSION: The anterior construct plate - 1/3 tube buttress plate fixation provided a better stable construct for early sitting. The standing mode yielded more significant differences between the groups. Placing a 1/3 tube buttress-plate via an anterior approach is a novel method of providing quadrilateral area support in this setting. Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo 2013-07 /pmc/articles/PMC3714991/ /pubmed/23917670 http://dx.doi.org/10.6061/clinics/2013(07)22 Text en Copyright © 2013 Hospital das Clínicas da FMUSP http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Basic Research
Wu, Yong-De
Cai, Xian-Hua
Liu, Xi-Ming
Zhang, Hong-Xi
Biomechanical analysis of the acetabular buttress-plate: are complex acetabular fractures in the quadrilateral area stable after treatment with anterior construct plate-1/3 tube buttress plate fixation?
title Biomechanical analysis of the acetabular buttress-plate: are complex acetabular fractures in the quadrilateral area stable after treatment with anterior construct plate-1/3 tube buttress plate fixation?
title_full Biomechanical analysis of the acetabular buttress-plate: are complex acetabular fractures in the quadrilateral area stable after treatment with anterior construct plate-1/3 tube buttress plate fixation?
title_fullStr Biomechanical analysis of the acetabular buttress-plate: are complex acetabular fractures in the quadrilateral area stable after treatment with anterior construct plate-1/3 tube buttress plate fixation?
title_full_unstemmed Biomechanical analysis of the acetabular buttress-plate: are complex acetabular fractures in the quadrilateral area stable after treatment with anterior construct plate-1/3 tube buttress plate fixation?
title_short Biomechanical analysis of the acetabular buttress-plate: are complex acetabular fractures in the quadrilateral area stable after treatment with anterior construct plate-1/3 tube buttress plate fixation?
title_sort biomechanical analysis of the acetabular buttress-plate: are complex acetabular fractures in the quadrilateral area stable after treatment with anterior construct plate-1/3 tube buttress plate fixation?
topic Basic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3714991/
https://www.ncbi.nlm.nih.gov/pubmed/23917670
http://dx.doi.org/10.6061/clinics/2013(07)22
work_keys_str_mv AT wuyongde biomechanicalanalysisoftheacetabularbuttressplatearecomplexacetabularfracturesinthequadrilateralareastableaftertreatmentwithanteriorconstructplate13tubebuttressplatefixation
AT caixianhua biomechanicalanalysisoftheacetabularbuttressplatearecomplexacetabularfracturesinthequadrilateralareastableaftertreatmentwithanteriorconstructplate13tubebuttressplatefixation
AT liuximing biomechanicalanalysisoftheacetabularbuttressplatearecomplexacetabularfracturesinthequadrilateralareastableaftertreatmentwithanteriorconstructplate13tubebuttressplatefixation
AT zhanghongxi biomechanicalanalysisoftheacetabularbuttressplatearecomplexacetabularfracturesinthequadrilateralareastableaftertreatmentwithanteriorconstructplate13tubebuttressplatefixation