Improved relationship between left and right ventricular electrical activation after cardiac resynchronization therapy in heart failure patients can be quantified by body surface potential mapping
OBJECTIVES: Few studies have evaluated cardiac electrical activation dynamics after cardiac resynchronization therapy. Although this procedure reduces morbidity and mortality in heart failure patients, many approaches attempting to identify the responders have shown that 30% of patients do not attai...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3715027/ https://www.ncbi.nlm.nih.gov/pubmed/23917664 http://dx.doi.org/10.6061/clinics/2013(07)16 |
_version_ | 1782277412424253440 |
---|---|
author | Samesima, Nelson Pastore, Carlos Alberto Douglas, Roberto Andrés Filho, Martino Martinelli Pedrosa, Anísio A. |
author_facet | Samesima, Nelson Pastore, Carlos Alberto Douglas, Roberto Andrés Filho, Martino Martinelli Pedrosa, Anísio A. |
author_sort | Samesima, Nelson |
collection | PubMed |
description | OBJECTIVES: Few studies have evaluated cardiac electrical activation dynamics after cardiac resynchronization therapy. Although this procedure reduces morbidity and mortality in heart failure patients, many approaches attempting to identify the responders have shown that 30% of patients do not attain clinical or functional improvement. This study sought to quantify and characterize the effect of resynchronization therapy on the ventricular electrical activation of patients using body surface potential mapping, a noninvasive tool. METHODS: This retrospective study included 91 resynchronization patients with a mean age of 61 years, left ventricle ejection fraction of 28%, mean QRS duration of 182 ms, and functional class III/IV (78%/22%); the patients underwent 87-lead body surface mapping with the resynchronization device on and off. Thirty-six patients were excluded. Body surface isochronal maps produced 87 maximal/mean global ventricular activation times with three regions identified. The regional activation times for right and left ventricles and their inter-regional right-to-left ventricle gradients were calculated from these results and analyzed. The Mann-Whitney U-test and Kruskall-Wallis test were used for comparisons, with the level of significance set at p≤0.05. RESULTS: During intrinsic rhythms, regional ventricular activation times were significantly different (54.5 ms vs. 95.9 ms in the right and left ventricle regions, respectively). Regarding cardiac resynchronization, the maximal global value was significantly reduced (138 ms to 131 ms), and a downward variation of 19.4% in regional-left and an upward variation of 44.8% in regional-right ventricular activation times resulted in a significantly reduced inter-regional gradient (43.8 ms to 17 ms). CONCLUSIONS: Body surface potential mapping in resynchronization patients yielded electrical ventricular activation times for two cardiac regions with significantly decreased global and regional-left values but significantly increased regional-right values, thus showing an attenuated inter-regional gradient after the cardiac resynchronization therapy. |
format | Online Article Text |
id | pubmed-3715027 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo |
record_format | MEDLINE/PubMed |
spelling | pubmed-37150272013-07-22 Improved relationship between left and right ventricular electrical activation after cardiac resynchronization therapy in heart failure patients can be quantified by body surface potential mapping Samesima, Nelson Pastore, Carlos Alberto Douglas, Roberto Andrés Filho, Martino Martinelli Pedrosa, Anísio A. Clinics (Sao Paulo) Clinical Science OBJECTIVES: Few studies have evaluated cardiac electrical activation dynamics after cardiac resynchronization therapy. Although this procedure reduces morbidity and mortality in heart failure patients, many approaches attempting to identify the responders have shown that 30% of patients do not attain clinical or functional improvement. This study sought to quantify and characterize the effect of resynchronization therapy on the ventricular electrical activation of patients using body surface potential mapping, a noninvasive tool. METHODS: This retrospective study included 91 resynchronization patients with a mean age of 61 years, left ventricle ejection fraction of 28%, mean QRS duration of 182 ms, and functional class III/IV (78%/22%); the patients underwent 87-lead body surface mapping with the resynchronization device on and off. Thirty-six patients were excluded. Body surface isochronal maps produced 87 maximal/mean global ventricular activation times with three regions identified. The regional activation times for right and left ventricles and their inter-regional right-to-left ventricle gradients were calculated from these results and analyzed. The Mann-Whitney U-test and Kruskall-Wallis test were used for comparisons, with the level of significance set at p≤0.05. RESULTS: During intrinsic rhythms, regional ventricular activation times were significantly different (54.5 ms vs. 95.9 ms in the right and left ventricle regions, respectively). Regarding cardiac resynchronization, the maximal global value was significantly reduced (138 ms to 131 ms), and a downward variation of 19.4% in regional-left and an upward variation of 44.8% in regional-right ventricular activation times resulted in a significantly reduced inter-regional gradient (43.8 ms to 17 ms). CONCLUSIONS: Body surface potential mapping in resynchronization patients yielded electrical ventricular activation times for two cardiac regions with significantly decreased global and regional-left values but significantly increased regional-right values, thus showing an attenuated inter-regional gradient after the cardiac resynchronization therapy. Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo 2013-07 /pmc/articles/PMC3715027/ /pubmed/23917664 http://dx.doi.org/10.6061/clinics/2013(07)16 Text en Copyright © 2013 Hospital das Clínicas da FMUSP http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Science Samesima, Nelson Pastore, Carlos Alberto Douglas, Roberto Andrés Filho, Martino Martinelli Pedrosa, Anísio A. Improved relationship between left and right ventricular electrical activation after cardiac resynchronization therapy in heart failure patients can be quantified by body surface potential mapping |
title | Improved relationship between left and right ventricular electrical activation after cardiac resynchronization therapy in heart failure patients can be quantified by body surface potential mapping |
title_full | Improved relationship between left and right ventricular electrical activation after cardiac resynchronization therapy in heart failure patients can be quantified by body surface potential mapping |
title_fullStr | Improved relationship between left and right ventricular electrical activation after cardiac resynchronization therapy in heart failure patients can be quantified by body surface potential mapping |
title_full_unstemmed | Improved relationship between left and right ventricular electrical activation after cardiac resynchronization therapy in heart failure patients can be quantified by body surface potential mapping |
title_short | Improved relationship between left and right ventricular electrical activation after cardiac resynchronization therapy in heart failure patients can be quantified by body surface potential mapping |
title_sort | improved relationship between left and right ventricular electrical activation after cardiac resynchronization therapy in heart failure patients can be quantified by body surface potential mapping |
topic | Clinical Science |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3715027/ https://www.ncbi.nlm.nih.gov/pubmed/23917664 http://dx.doi.org/10.6061/clinics/2013(07)16 |
work_keys_str_mv | AT samesimanelson improvedrelationshipbetweenleftandrightventricularelectricalactivationaftercardiacresynchronizationtherapyinheartfailurepatientscanbequantifiedbybodysurfacepotentialmapping AT pastorecarlosalberto improvedrelationshipbetweenleftandrightventricularelectricalactivationaftercardiacresynchronizationtherapyinheartfailurepatientscanbequantifiedbybodysurfacepotentialmapping AT douglasrobertoandres improvedrelationshipbetweenleftandrightventricularelectricalactivationaftercardiacresynchronizationtherapyinheartfailurepatientscanbequantifiedbybodysurfacepotentialmapping AT filhomartinomartinelli improvedrelationshipbetweenleftandrightventricularelectricalactivationaftercardiacresynchronizationtherapyinheartfailurepatientscanbequantifiedbybodysurfacepotentialmapping AT pedrosaanisioa improvedrelationshipbetweenleftandrightventricularelectricalactivationaftercardiacresynchronizationtherapyinheartfailurepatientscanbequantifiedbybodysurfacepotentialmapping |