Cargando…

Simultaneous/Selective Detection of Dopamine and Ascorbic Acid at Synthetic Zeolite-Modified/Graphite-Epoxy Composite Macro/Quasi-Microelectrodes

The present paper aims to miniaturize a graphite-epoxy and synthetic zeolite-modified graphite-epoxy composite macroelectrode as a quasi-microelectrode aiming in vitro and also, envisaging in vivo simultaneous electrochemical detection of dopamine (DA) and ascorbic acid (AA) neurotransmitters, or DA...

Descripción completa

Detalles Bibliográficos
Autores principales: Ilinoiu, Elida Cristina, Manea, Florica, Serra, Pier Andrea, Pode, Rodica
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3715222/
https://www.ncbi.nlm.nih.gov/pubmed/23736851
http://dx.doi.org/10.3390/s130607296
_version_ 1782277420005457920
author Ilinoiu, Elida Cristina
Manea, Florica
Serra, Pier Andrea
Pode, Rodica
author_facet Ilinoiu, Elida Cristina
Manea, Florica
Serra, Pier Andrea
Pode, Rodica
author_sort Ilinoiu, Elida Cristina
collection PubMed
description The present paper aims to miniaturize a graphite-epoxy and synthetic zeolite-modified graphite-epoxy composite macroelectrode as a quasi-microelectrode aiming in vitro and also, envisaging in vivo simultaneous electrochemical detection of dopamine (DA) and ascorbic acid (AA) neurotransmitters, or DA detection in the presence of AA. The electrochemical behavior and the response of the designed materials to the presence of dopamine and ascorbic acid without any protective membranes were studied by cyclic voltammetry and constant-potential amperometry techniques. The catalytic effect towards dopamine detection was proved for the synthetic zeolite-modified graphite-epoxy composite quasi-microelectrode, allowing increasing the sensitivity and selectivity for this analyte detection, besides a possible electrostatic attraction between dopamine cation and the negative surface of the synthetic zeolite and electrostatic repulsion with ascorbic acid anion. Also, the synthetic zeolite-modified graphite-epoxy composite quasi-microelectrode gave the best electroanalytical parameters for dopamine detection using constant-potential amperometry, the most useful technique for practical applications.
format Online
Article
Text
id pubmed-3715222
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-37152222013-07-24 Simultaneous/Selective Detection of Dopamine and Ascorbic Acid at Synthetic Zeolite-Modified/Graphite-Epoxy Composite Macro/Quasi-Microelectrodes Ilinoiu, Elida Cristina Manea, Florica Serra, Pier Andrea Pode, Rodica Sensors (Basel) Article The present paper aims to miniaturize a graphite-epoxy and synthetic zeolite-modified graphite-epoxy composite macroelectrode as a quasi-microelectrode aiming in vitro and also, envisaging in vivo simultaneous electrochemical detection of dopamine (DA) and ascorbic acid (AA) neurotransmitters, or DA detection in the presence of AA. The electrochemical behavior and the response of the designed materials to the presence of dopamine and ascorbic acid without any protective membranes were studied by cyclic voltammetry and constant-potential amperometry techniques. The catalytic effect towards dopamine detection was proved for the synthetic zeolite-modified graphite-epoxy composite quasi-microelectrode, allowing increasing the sensitivity and selectivity for this analyte detection, besides a possible electrostatic attraction between dopamine cation and the negative surface of the synthetic zeolite and electrostatic repulsion with ascorbic acid anion. Also, the synthetic zeolite-modified graphite-epoxy composite quasi-microelectrode gave the best electroanalytical parameters for dopamine detection using constant-potential amperometry, the most useful technique for practical applications. Molecular Diversity Preservation International (MDPI) 2013-06-03 /pmc/articles/PMC3715222/ /pubmed/23736851 http://dx.doi.org/10.3390/s130607296 Text en © 2013 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Ilinoiu, Elida Cristina
Manea, Florica
Serra, Pier Andrea
Pode, Rodica
Simultaneous/Selective Detection of Dopamine and Ascorbic Acid at Synthetic Zeolite-Modified/Graphite-Epoxy Composite Macro/Quasi-Microelectrodes
title Simultaneous/Selective Detection of Dopamine and Ascorbic Acid at Synthetic Zeolite-Modified/Graphite-Epoxy Composite Macro/Quasi-Microelectrodes
title_full Simultaneous/Selective Detection of Dopamine and Ascorbic Acid at Synthetic Zeolite-Modified/Graphite-Epoxy Composite Macro/Quasi-Microelectrodes
title_fullStr Simultaneous/Selective Detection of Dopamine and Ascorbic Acid at Synthetic Zeolite-Modified/Graphite-Epoxy Composite Macro/Quasi-Microelectrodes
title_full_unstemmed Simultaneous/Selective Detection of Dopamine and Ascorbic Acid at Synthetic Zeolite-Modified/Graphite-Epoxy Composite Macro/Quasi-Microelectrodes
title_short Simultaneous/Selective Detection of Dopamine and Ascorbic Acid at Synthetic Zeolite-Modified/Graphite-Epoxy Composite Macro/Quasi-Microelectrodes
title_sort simultaneous/selective detection of dopamine and ascorbic acid at synthetic zeolite-modified/graphite-epoxy composite macro/quasi-microelectrodes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3715222/
https://www.ncbi.nlm.nih.gov/pubmed/23736851
http://dx.doi.org/10.3390/s130607296
work_keys_str_mv AT ilinoiuelidacristina simultaneousselectivedetectionofdopamineandascorbicacidatsyntheticzeolitemodifiedgraphiteepoxycompositemacroquasimicroelectrodes
AT maneaflorica simultaneousselectivedetectionofdopamineandascorbicacidatsyntheticzeolitemodifiedgraphiteepoxycompositemacroquasimicroelectrodes
AT serrapierandrea simultaneousselectivedetectionofdopamineandascorbicacidatsyntheticzeolitemodifiedgraphiteepoxycompositemacroquasimicroelectrodes
AT poderodica simultaneousselectivedetectionofdopamineandascorbicacidatsyntheticzeolitemodifiedgraphiteepoxycompositemacroquasimicroelectrodes