Cargando…

Detection of Fibrinogen and Coagulation Factor VIII in Plasma by a Quartz Crystal Microbalance Biosensor

A quartz crystal microbalance (QCM) biosensor with nanogram sensitivity has been constructed through a reasonable designing and biological processing of the piezoelectric quartz crystals. Due to its highly sensitivity, real time detection and low cost, the proposed QCM biosensor has a promising pote...

Descripción completa

Detalles Bibliográficos
Autores principales: Yao, Chunyan, Qu, Ling, Fu, Weiling
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3715226/
https://www.ncbi.nlm.nih.gov/pubmed/23708275
http://dx.doi.org/10.3390/s130606946
_version_ 1782277420925059072
author Yao, Chunyan
Qu, Ling
Fu, Weiling
author_facet Yao, Chunyan
Qu, Ling
Fu, Weiling
author_sort Yao, Chunyan
collection PubMed
description A quartz crystal microbalance (QCM) biosensor with nanogram sensitivity has been constructed through a reasonable designing and biological processing of the piezoelectric quartz crystals. Due to its highly sensitivity, real time detection and low cost, the proposed QCM biosensor has a promising potential in blood coagulation research. In the current study, the QCM biosensor was used to determine the activated partial thromboplastin time (APTT) for 120 anticoagulated plasma specimens. A good linear relationship was found in a double-logarithmic plot of APTT versus fibrinogen concentration in the range of 1.58–6.30 g/L. For factor VIII, the detection range by the QCM biosensor is 0.0185–0.111 mg/L. The QCM biosensor results were compared with those obtained by commercial optical coagulometry and a good agreement (correlation coefficient is 0.949 for fibrinogen, and 0.948 for factor VIII) was reached. Furthermore, the QCM determination can be completed within 10 min. Our study suggested that the proposed QCM biosensor could provide for more convenient and time saving operations, which may be useful in clinical situations for rapid monitoring of anticoagulant therapy using small volume (20 μL) plasma specimens.
format Online
Article
Text
id pubmed-3715226
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-37152262013-07-24 Detection of Fibrinogen and Coagulation Factor VIII in Plasma by a Quartz Crystal Microbalance Biosensor Yao, Chunyan Qu, Ling Fu, Weiling Sensors (Basel) Article A quartz crystal microbalance (QCM) biosensor with nanogram sensitivity has been constructed through a reasonable designing and biological processing of the piezoelectric quartz crystals. Due to its highly sensitivity, real time detection and low cost, the proposed QCM biosensor has a promising potential in blood coagulation research. In the current study, the QCM biosensor was used to determine the activated partial thromboplastin time (APTT) for 120 anticoagulated plasma specimens. A good linear relationship was found in a double-logarithmic plot of APTT versus fibrinogen concentration in the range of 1.58–6.30 g/L. For factor VIII, the detection range by the QCM biosensor is 0.0185–0.111 mg/L. The QCM biosensor results were compared with those obtained by commercial optical coagulometry and a good agreement (correlation coefficient is 0.949 for fibrinogen, and 0.948 for factor VIII) was reached. Furthermore, the QCM determination can be completed within 10 min. Our study suggested that the proposed QCM biosensor could provide for more convenient and time saving operations, which may be useful in clinical situations for rapid monitoring of anticoagulant therapy using small volume (20 μL) plasma specimens. Molecular Diversity Preservation International (MDPI) 2013-05-24 /pmc/articles/PMC3715226/ /pubmed/23708275 http://dx.doi.org/10.3390/s130606946 Text en © 2013 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Yao, Chunyan
Qu, Ling
Fu, Weiling
Detection of Fibrinogen and Coagulation Factor VIII in Plasma by a Quartz Crystal Microbalance Biosensor
title Detection of Fibrinogen and Coagulation Factor VIII in Plasma by a Quartz Crystal Microbalance Biosensor
title_full Detection of Fibrinogen and Coagulation Factor VIII in Plasma by a Quartz Crystal Microbalance Biosensor
title_fullStr Detection of Fibrinogen and Coagulation Factor VIII in Plasma by a Quartz Crystal Microbalance Biosensor
title_full_unstemmed Detection of Fibrinogen and Coagulation Factor VIII in Plasma by a Quartz Crystal Microbalance Biosensor
title_short Detection of Fibrinogen and Coagulation Factor VIII in Plasma by a Quartz Crystal Microbalance Biosensor
title_sort detection of fibrinogen and coagulation factor viii in plasma by a quartz crystal microbalance biosensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3715226/
https://www.ncbi.nlm.nih.gov/pubmed/23708275
http://dx.doi.org/10.3390/s130606946
work_keys_str_mv AT yaochunyan detectionoffibrinogenandcoagulationfactorviiiinplasmabyaquartzcrystalmicrobalancebiosensor
AT quling detectionoffibrinogenandcoagulationfactorviiiinplasmabyaquartzcrystalmicrobalancebiosensor
AT fuweiling detectionoffibrinogenandcoagulationfactorviiiinplasmabyaquartzcrystalmicrobalancebiosensor