Effects of flashlight guidance on chest compression performance in cardiopulmonary resuscitation in a noisy environment

BACKGROUND: In real cardiopulmonary resuscitation (CPR), noise can arise from instructional voices and environmental sounds in places such as a battlefield and industrial and high-traffic areas. A feedback device using a flashing light was designed to overcome noise-induced stimulus saturation durin...

Descripción completa

Detalles Bibliográficos
Autores principales: You, Je Sung, Chung, Sung Phil, Chang, Chul Ho, Park, Incheol, Lee, Hye Sun, Kim, SeungHo, Lee, Hahn Shick
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Group 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3717614/
https://www.ncbi.nlm.nih.gov/pubmed/22927635
http://dx.doi.org/10.1136/emermed-2012-201605
_version_ 1782277711951036416
author You, Je Sung
Chung, Sung Phil
Chang, Chul Ho
Park, Incheol
Lee, Hye Sun
Kim, SeungHo
Lee, Hahn Shick
author_facet You, Je Sung
Chung, Sung Phil
Chang, Chul Ho
Park, Incheol
Lee, Hye Sun
Kim, SeungHo
Lee, Hahn Shick
author_sort You, Je Sung
collection PubMed
description BACKGROUND: In real cardiopulmonary resuscitation (CPR), noise can arise from instructional voices and environmental sounds in places such as a battlefield and industrial and high-traffic areas. A feedback device using a flashing light was designed to overcome noise-induced stimulus saturation during CPR. This study was conducted to determine whether ‘flashlight’ guidance influences CPR performance in a simulated noisy setting. MATERIALS AND METHODS: We recruited 30 senior medical students with no previous experience of using flashlight-guided CPR to participate in this prospective, simulation-based, crossover study. The experiment was conducted in a simulated noisy situation using a cardiac arrest model without ventilation. Noise such as patrol car and fire engine sirens was artificially generated. The flashlight guidance device emitted light pulses at the rate of 100 flashes/min. Participants also received instructions to achieve the desired rate of 100 compressions/min. CPR performances were recorded with a Resusci Anne mannequin with a computer skill-reporting system. RESULTS: There were significant differences between the control and flashlight groups in mean compression rate (MCR), MCR/min and visual analogue scale. However, there were no significant differences in correct compression depth, mean compression depth, correct hand position, and correctly released compression. The flashlight group constantly maintained the pace at the desired 100 compressions/min. Furthermore, the flashlight group had a tendency to keep the MCR constant, whereas the control group had a tendency to decrease it after 60 s. CONCLUSION: Flashlight-guided CPR is particularly advantageous for maintaining a desired MCR during hands-only CPR in noisy environments, where metronome pacing might not be clearly heard.
format Online
Article
Text
id pubmed-3717614
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BMJ Group
record_format MEDLINE/PubMed
spelling pubmed-37176142013-07-23 Effects of flashlight guidance on chest compression performance in cardiopulmonary resuscitation in a noisy environment You, Je Sung Chung, Sung Phil Chang, Chul Ho Park, Incheol Lee, Hye Sun Kim, SeungHo Lee, Hahn Shick Emerg Med J Original Article BACKGROUND: In real cardiopulmonary resuscitation (CPR), noise can arise from instructional voices and environmental sounds in places such as a battlefield and industrial and high-traffic areas. A feedback device using a flashing light was designed to overcome noise-induced stimulus saturation during CPR. This study was conducted to determine whether ‘flashlight’ guidance influences CPR performance in a simulated noisy setting. MATERIALS AND METHODS: We recruited 30 senior medical students with no previous experience of using flashlight-guided CPR to participate in this prospective, simulation-based, crossover study. The experiment was conducted in a simulated noisy situation using a cardiac arrest model without ventilation. Noise such as patrol car and fire engine sirens was artificially generated. The flashlight guidance device emitted light pulses at the rate of 100 flashes/min. Participants also received instructions to achieve the desired rate of 100 compressions/min. CPR performances were recorded with a Resusci Anne mannequin with a computer skill-reporting system. RESULTS: There were significant differences between the control and flashlight groups in mean compression rate (MCR), MCR/min and visual analogue scale. However, there were no significant differences in correct compression depth, mean compression depth, correct hand position, and correctly released compression. The flashlight group constantly maintained the pace at the desired 100 compressions/min. Furthermore, the flashlight group had a tendency to keep the MCR constant, whereas the control group had a tendency to decrease it after 60 s. CONCLUSION: Flashlight-guided CPR is particularly advantageous for maintaining a desired MCR during hands-only CPR in noisy environments, where metronome pacing might not be clearly heard. BMJ Group 2013-08 2012-08-27 /pmc/articles/PMC3717614/ /pubmed/22927635 http://dx.doi.org/10.1136/emermed-2012-201605 Text en Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 3.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Original Article
You, Je Sung
Chung, Sung Phil
Chang, Chul Ho
Park, Incheol
Lee, Hye Sun
Kim, SeungHo
Lee, Hahn Shick
Effects of flashlight guidance on chest compression performance in cardiopulmonary resuscitation in a noisy environment
title Effects of flashlight guidance on chest compression performance in cardiopulmonary resuscitation in a noisy environment
title_full Effects of flashlight guidance on chest compression performance in cardiopulmonary resuscitation in a noisy environment
title_fullStr Effects of flashlight guidance on chest compression performance in cardiopulmonary resuscitation in a noisy environment
title_full_unstemmed Effects of flashlight guidance on chest compression performance in cardiopulmonary resuscitation in a noisy environment
title_short Effects of flashlight guidance on chest compression performance in cardiopulmonary resuscitation in a noisy environment
title_sort effects of flashlight guidance on chest compression performance in cardiopulmonary resuscitation in a noisy environment
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3717614/
https://www.ncbi.nlm.nih.gov/pubmed/22927635
http://dx.doi.org/10.1136/emermed-2012-201605
work_keys_str_mv AT youjesung effectsofflashlightguidanceonchestcompressionperformanceincardiopulmonaryresuscitationinanoisyenvironment
AT chungsungphil effectsofflashlightguidanceonchestcompressionperformanceincardiopulmonaryresuscitationinanoisyenvironment
AT changchulho effectsofflashlightguidanceonchestcompressionperformanceincardiopulmonaryresuscitationinanoisyenvironment
AT parkincheol effectsofflashlightguidanceonchestcompressionperformanceincardiopulmonaryresuscitationinanoisyenvironment
AT leehyesun effectsofflashlightguidanceonchestcompressionperformanceincardiopulmonaryresuscitationinanoisyenvironment
AT kimseungho effectsofflashlightguidanceonchestcompressionperformanceincardiopulmonaryresuscitationinanoisyenvironment
AT leehahnshick effectsofflashlightguidanceonchestcompressionperformanceincardiopulmonaryresuscitationinanoisyenvironment