Morphological evaluation of eccentric sets guide-plates of dcp-l 4.5 mm
OBJECTIVE: To carry out isolated and comparative evaluations of the measurements of the set eccentric guide plates used in 4.5mm surgical implants, and to determine the effect of these measurements on compression strength. METHODS: Four eccentric guides, four large dynamic compression plates (L-DCP)...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sociedade Brasileira de Ortopedia e Traumatologia Regional de São
Paulo
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3718412/ https://www.ncbi.nlm.nih.gov/pubmed/24453573 http://dx.doi.org/10.1590/S1413-78522012000100002 |
_version_ | 1782277773047365632 |
---|---|
author | Borges, José Humberto de Souza da Silva Filho, Antonio Lisboa Pereira Neto, Francisco Daher, Walter Rodrigo de Mesquita, Alessandro Queiroz Freitas, Anderson |
author_facet | Borges, José Humberto de Souza da Silva Filho, Antonio Lisboa Pereira Neto, Francisco Daher, Walter Rodrigo de Mesquita, Alessandro Queiroz Freitas, Anderson |
author_sort | Borges, José Humberto de Souza |
collection | PubMed |
description | OBJECTIVE: To carry out isolated and comparative evaluations of the measurements of the set eccentric guide plates used in 4.5mm surgical implants, and to determine the effect of these measurements on compression strength. METHODS: Four eccentric guides, four large dynamic compression plates (L-DCP) from four local manufacturers, and a Vonder(®) 200 mm caliper brand were used. Five standard parameter measurements were created for the set eccentric guide-plate, which were identified as A to E. Four sets were made, using materials of the same factory, and identified as groups I to IV. The analyses were performed by measuring all the parameters from a ventral view of the plate, with the eccentric guide placed in the plate hole. RESULTS: Groups I and II showed the same values for all the parameters. All the groups showed the same measurements for E = 8.15 e B = 3.60. Group III: A = 8.10mm, C = 3.25mm, D = 1.25mm. Group IV: A = 7.00mm, C = 3.10mm, D = 0.30mm. Maximum compression force was (F Max.): Group I 80.58 N, Group. II: F Max. 81.63 N, Group. III: F Max. 36.32N, Group. IV: F Max. 37.52N CONCLUSION: The measurements evaluated show a lack of standardization in the manufacture of orthopedic instruments and its effects on the values for compression strength. Level of Evidence: Level III, analytical study. |
format | Online Article Text |
id | pubmed-3718412 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Sociedade Brasileira de Ortopedia e Traumatologia Regional de São
Paulo |
record_format | MEDLINE/PubMed |
spelling | pubmed-37184122014-01-22 Morphological evaluation of eccentric sets guide-plates of dcp-l 4.5 mm Borges, José Humberto de Souza da Silva Filho, Antonio Lisboa Pereira Neto, Francisco Daher, Walter Rodrigo de Mesquita, Alessandro Queiroz Freitas, Anderson Acta Ortop Bras Original Article OBJECTIVE: To carry out isolated and comparative evaluations of the measurements of the set eccentric guide plates used in 4.5mm surgical implants, and to determine the effect of these measurements on compression strength. METHODS: Four eccentric guides, four large dynamic compression plates (L-DCP) from four local manufacturers, and a Vonder(®) 200 mm caliper brand were used. Five standard parameter measurements were created for the set eccentric guide-plate, which were identified as A to E. Four sets were made, using materials of the same factory, and identified as groups I to IV. The analyses were performed by measuring all the parameters from a ventral view of the plate, with the eccentric guide placed in the plate hole. RESULTS: Groups I and II showed the same values for all the parameters. All the groups showed the same measurements for E = 8.15 e B = 3.60. Group III: A = 8.10mm, C = 3.25mm, D = 1.25mm. Group IV: A = 7.00mm, C = 3.10mm, D = 0.30mm. Maximum compression force was (F Max.): Group I 80.58 N, Group. II: F Max. 81.63 N, Group. III: F Max. 36.32N, Group. IV: F Max. 37.52N CONCLUSION: The measurements evaluated show a lack of standardization in the manufacture of orthopedic instruments and its effects on the values for compression strength. Level of Evidence: Level III, analytical study. Sociedade Brasileira de Ortopedia e Traumatologia Regional de São Paulo 2012 /pmc/articles/PMC3718412/ /pubmed/24453573 http://dx.doi.org/10.1590/S1413-78522012000100002 Text en http://creativecommons.org/licenses/by-nc/3.0/ All the content of the journal, except where otherwise noted, is licensed under a Creative Commons License. |
spellingShingle | Original Article Borges, José Humberto de Souza da Silva Filho, Antonio Lisboa Pereira Neto, Francisco Daher, Walter Rodrigo de Mesquita, Alessandro Queiroz Freitas, Anderson Morphological evaluation of eccentric sets guide-plates of dcp-l 4.5 mm |
title | Morphological evaluation of eccentric sets guide-plates of dcp-l 4.5
mm |
title_full | Morphological evaluation of eccentric sets guide-plates of dcp-l 4.5
mm |
title_fullStr | Morphological evaluation of eccentric sets guide-plates of dcp-l 4.5
mm |
title_full_unstemmed | Morphological evaluation of eccentric sets guide-plates of dcp-l 4.5
mm |
title_short | Morphological evaluation of eccentric sets guide-plates of dcp-l 4.5
mm |
title_sort | morphological evaluation of eccentric sets guide-plates of dcp-l 4.5
mm |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3718412/ https://www.ncbi.nlm.nih.gov/pubmed/24453573 http://dx.doi.org/10.1590/S1413-78522012000100002 |
work_keys_str_mv | AT borgesjosehumbertodesouza morphologicalevaluationofeccentricsetsguideplatesofdcpl45mm AT dasilvafilhoantoniolisboa morphologicalevaluationofeccentricsetsguideplatesofdcpl45mm AT pereiranetofrancisco morphologicalevaluationofeccentricsetsguideplatesofdcpl45mm AT daherwalterrodrigo morphologicalevaluationofeccentricsetsguideplatesofdcpl45mm AT demesquitaalessandroqueiroz morphologicalevaluationofeccentricsetsguideplatesofdcpl45mm AT freitasanderson morphologicalevaluationofeccentricsetsguideplatesofdcpl45mm |