Cargando…

Morphological evaluation of eccentric sets guide-plates of dcp-l 4.5 mm

OBJECTIVE: To carry out isolated and comparative evaluations of the measurements of the set eccentric guide plates used in 4.5mm surgical implants, and to determine the effect of these measurements on compression strength. METHODS: Four eccentric guides, four large dynamic compression plates (L-DCP)...

Descripción completa

Detalles Bibliográficos
Autores principales: Borges, José Humberto de Souza, da Silva Filho, Antonio Lisboa, Pereira Neto, Francisco, Daher, Walter Rodrigo, de Mesquita, Alessandro Queiroz, Freitas, Anderson
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sociedade Brasileira de Ortopedia e Traumatologia Regional de São Paulo 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3718412/
https://www.ncbi.nlm.nih.gov/pubmed/24453573
http://dx.doi.org/10.1590/S1413-78522012000100002
_version_ 1782277773047365632
author Borges, José Humberto de Souza
da Silva Filho, Antonio Lisboa
Pereira Neto, Francisco
Daher, Walter Rodrigo
de Mesquita, Alessandro Queiroz
Freitas, Anderson
author_facet Borges, José Humberto de Souza
da Silva Filho, Antonio Lisboa
Pereira Neto, Francisco
Daher, Walter Rodrigo
de Mesquita, Alessandro Queiroz
Freitas, Anderson
author_sort Borges, José Humberto de Souza
collection PubMed
description OBJECTIVE: To carry out isolated and comparative evaluations of the measurements of the set eccentric guide plates used in 4.5mm surgical implants, and to determine the effect of these measurements on compression strength. METHODS: Four eccentric guides, four large dynamic compression plates (L-DCP) from four local manufacturers, and a Vonder(®) 200 mm caliper brand were used. Five standard parameter measurements were created for the set eccentric guide-plate, which were identified as A to E. Four sets were made, using materials of the same factory, and identified as groups I to IV. The analyses were performed by measuring all the parameters from a ventral view of the plate, with the eccentric guide placed in the plate hole. RESULTS: Groups I and II showed the same values for all the parameters. All the groups showed the same measurements for E = 8.15 e B = 3.60. Group III: A = 8.10mm, C = 3.25mm, D = 1.25mm. Group IV: A = 7.00mm, C = 3.10mm, D = 0.30mm. Maximum compression force was (F Max.): Group I 80.58 N, Group. II: F Max. 81.63 N, Group. III: F Max. 36.32N, Group. IV: F Max. 37.52N CONCLUSION: The measurements evaluated show a lack of standardization in the manufacture of orthopedic instruments and its effects on the values for compression strength. Level of Evidence: Level III, analytical study.
format Online
Article
Text
id pubmed-3718412
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Sociedade Brasileira de Ortopedia e Traumatologia Regional de São Paulo
record_format MEDLINE/PubMed
spelling pubmed-37184122014-01-22 Morphological evaluation of eccentric sets guide-plates of dcp-l 4.5 mm Borges, José Humberto de Souza da Silva Filho, Antonio Lisboa Pereira Neto, Francisco Daher, Walter Rodrigo de Mesquita, Alessandro Queiroz Freitas, Anderson Acta Ortop Bras Original Article OBJECTIVE: To carry out isolated and comparative evaluations of the measurements of the set eccentric guide plates used in 4.5mm surgical implants, and to determine the effect of these measurements on compression strength. METHODS: Four eccentric guides, four large dynamic compression plates (L-DCP) from four local manufacturers, and a Vonder(®) 200 mm caliper brand were used. Five standard parameter measurements were created for the set eccentric guide-plate, which were identified as A to E. Four sets were made, using materials of the same factory, and identified as groups I to IV. The analyses were performed by measuring all the parameters from a ventral view of the plate, with the eccentric guide placed in the plate hole. RESULTS: Groups I and II showed the same values for all the parameters. All the groups showed the same measurements for E = 8.15 e B = 3.60. Group III: A = 8.10mm, C = 3.25mm, D = 1.25mm. Group IV: A = 7.00mm, C = 3.10mm, D = 0.30mm. Maximum compression force was (F Max.): Group I 80.58 N, Group. II: F Max. 81.63 N, Group. III: F Max. 36.32N, Group. IV: F Max. 37.52N CONCLUSION: The measurements evaluated show a lack of standardization in the manufacture of orthopedic instruments and its effects on the values for compression strength. Level of Evidence: Level III, analytical study. Sociedade Brasileira de Ortopedia e Traumatologia Regional de São Paulo 2012 /pmc/articles/PMC3718412/ /pubmed/24453573 http://dx.doi.org/10.1590/S1413-78522012000100002 Text en http://creativecommons.org/licenses/by-nc/3.0/ All the content of the journal, except where otherwise noted, is licensed under a Creative Commons License.
spellingShingle Original Article
Borges, José Humberto de Souza
da Silva Filho, Antonio Lisboa
Pereira Neto, Francisco
Daher, Walter Rodrigo
de Mesquita, Alessandro Queiroz
Freitas, Anderson
Morphological evaluation of eccentric sets guide-plates of dcp-l 4.5 mm
title Morphological evaluation of eccentric sets guide-plates of dcp-l 4.5 mm
title_full Morphological evaluation of eccentric sets guide-plates of dcp-l 4.5 mm
title_fullStr Morphological evaluation of eccentric sets guide-plates of dcp-l 4.5 mm
title_full_unstemmed Morphological evaluation of eccentric sets guide-plates of dcp-l 4.5 mm
title_short Morphological evaluation of eccentric sets guide-plates of dcp-l 4.5 mm
title_sort morphological evaluation of eccentric sets guide-plates of dcp-l 4.5 mm
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3718412/
https://www.ncbi.nlm.nih.gov/pubmed/24453573
http://dx.doi.org/10.1590/S1413-78522012000100002
work_keys_str_mv AT borgesjosehumbertodesouza morphologicalevaluationofeccentricsetsguideplatesofdcpl45mm
AT dasilvafilhoantoniolisboa morphologicalevaluationofeccentricsetsguideplatesofdcpl45mm
AT pereiranetofrancisco morphologicalevaluationofeccentricsetsguideplatesofdcpl45mm
AT daherwalterrodrigo morphologicalevaluationofeccentricsetsguideplatesofdcpl45mm
AT demesquitaalessandroqueiroz morphologicalevaluationofeccentricsetsguideplatesofdcpl45mm
AT freitasanderson morphologicalevaluationofeccentricsetsguideplatesofdcpl45mm