Cargando…

Reversed-phase High-performance Liquid Chromatography Method for Analysis of Curcuminoids and Curcuminoid-loaded Liposome Formulation

A simple, sensitive, precise and specific method for the determination of curcuminoids and curcuminoid-loaded liposome formulation was developed using reverse-phase high-performance liquid chromatography method. The analysis was performed isocratically on Zorbax Eclipse XDB-C18 column (150×4 mm, 5 μ...

Descripción completa

Detalles Bibliográficos
Autores principales: Jangle, R. D., Thorat, B. N.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3719151/
https://www.ncbi.nlm.nih.gov/pubmed/23901162
http://dx.doi.org/10.4103/0250-474X.113555
_version_ 1782277869425131520
author Jangle, R. D.
Thorat, B. N.
author_facet Jangle, R. D.
Thorat, B. N.
author_sort Jangle, R. D.
collection PubMed
description A simple, sensitive, precise and specific method for the determination of curcuminoids and curcuminoid-loaded liposome formulation was developed using reverse-phase high-performance liquid chromatography method. The analysis was performed isocratically on Zorbax Eclipse XDB-C18 column (150×4 mm, 5 μm), analytical column using UV detector and mobile phase consisting of 0.1% orthophosphoric acid and acetonitrile. The proposed method for curcuminoids was validated for linearity in the range from 50 to 300 ΅g/ml with correlation coefficient above 0.997. Intraday and interday precision studies showed the relative standard deviation less than 2%. The limit of detection and limit of quantitation values were 2.5 and 8.25 ΅g/ml, respectively. Forced degradation study for curcuminoids and liposomal curcuminoids sample was carried out and observed that proposed method was also suitable for finding degradation products in the sample. Proposed method was successfully applied to estimate curcuminoids content without any interference of other excipients from liposomal formulation. Therefore, the method developed is well suited for curcuminoids and its liposome estimation.
format Online
Article
Text
id pubmed-3719151
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-37191512013-07-30 Reversed-phase High-performance Liquid Chromatography Method for Analysis of Curcuminoids and Curcuminoid-loaded Liposome Formulation Jangle, R. D. Thorat, B. N. Indian J Pharm Sci Research Paper A simple, sensitive, precise and specific method for the determination of curcuminoids and curcuminoid-loaded liposome formulation was developed using reverse-phase high-performance liquid chromatography method. The analysis was performed isocratically on Zorbax Eclipse XDB-C18 column (150×4 mm, 5 μm), analytical column using UV detector and mobile phase consisting of 0.1% orthophosphoric acid and acetonitrile. The proposed method for curcuminoids was validated for linearity in the range from 50 to 300 ΅g/ml with correlation coefficient above 0.997. Intraday and interday precision studies showed the relative standard deviation less than 2%. The limit of detection and limit of quantitation values were 2.5 and 8.25 ΅g/ml, respectively. Forced degradation study for curcuminoids and liposomal curcuminoids sample was carried out and observed that proposed method was also suitable for finding degradation products in the sample. Proposed method was successfully applied to estimate curcuminoids content without any interference of other excipients from liposomal formulation. Therefore, the method developed is well suited for curcuminoids and its liposome estimation. Medknow Publications & Media Pvt Ltd 2013 /pmc/articles/PMC3719151/ /pubmed/23901162 http://dx.doi.org/10.4103/0250-474X.113555 Text en Copyright: © Indian Journal of Pharmaceutical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Paper
Jangle, R. D.
Thorat, B. N.
Reversed-phase High-performance Liquid Chromatography Method for Analysis of Curcuminoids and Curcuminoid-loaded Liposome Formulation
title Reversed-phase High-performance Liquid Chromatography Method for Analysis of Curcuminoids and Curcuminoid-loaded Liposome Formulation
title_full Reversed-phase High-performance Liquid Chromatography Method for Analysis of Curcuminoids and Curcuminoid-loaded Liposome Formulation
title_fullStr Reversed-phase High-performance Liquid Chromatography Method for Analysis of Curcuminoids and Curcuminoid-loaded Liposome Formulation
title_full_unstemmed Reversed-phase High-performance Liquid Chromatography Method for Analysis of Curcuminoids and Curcuminoid-loaded Liposome Formulation
title_short Reversed-phase High-performance Liquid Chromatography Method for Analysis of Curcuminoids and Curcuminoid-loaded Liposome Formulation
title_sort reversed-phase high-performance liquid chromatography method for analysis of curcuminoids and curcuminoid-loaded liposome formulation
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3719151/
https://www.ncbi.nlm.nih.gov/pubmed/23901162
http://dx.doi.org/10.4103/0250-474X.113555
work_keys_str_mv AT janglerd reversedphasehighperformanceliquidchromatographymethodforanalysisofcurcuminoidsandcurcuminoidloadedliposomeformulation
AT thoratbn reversedphasehighperformanceliquidchromatographymethodforanalysisofcurcuminoidsandcurcuminoidloadedliposomeformulation