Cargando…

Dried-Blood Spots: A Cost-Effective Field Method for the Detection of Chikungunya Virus Circulation in Remote Areas

BACKGROUND: In 2005, there were outbreaks of febrile polyarthritis due to Chikungunya virus (CHIKV) in the Comoros Islands. CHIKV then spread to other islands in the Indian Ocean: La Réunion, Mauritius, Seychelles and Madagascar. These outbreaks revealed the lack of surveillance and preparedness of...

Descripción completa

Detalles Bibliográficos
Autores principales: Andriamandimby, Soa Fy, Heraud, Jean-Michel, Randrianasolo, Laurence, Rafisandratantsoa, Jean Théophile, Andriamamonjy, Seta, Richard, Vincent
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3723542/
https://www.ncbi.nlm.nih.gov/pubmed/23936570
http://dx.doi.org/10.1371/journal.pntd.0002339
_version_ 1782278293621309440
author Andriamandimby, Soa Fy
Heraud, Jean-Michel
Randrianasolo, Laurence
Rafisandratantsoa, Jean Théophile
Andriamamonjy, Seta
Richard, Vincent
author_facet Andriamandimby, Soa Fy
Heraud, Jean-Michel
Randrianasolo, Laurence
Rafisandratantsoa, Jean Théophile
Andriamamonjy, Seta
Richard, Vincent
author_sort Andriamandimby, Soa Fy
collection PubMed
description BACKGROUND: In 2005, there were outbreaks of febrile polyarthritis due to Chikungunya virus (CHIKV) in the Comoros Islands. CHIKV then spread to other islands in the Indian Ocean: La Réunion, Mauritius, Seychelles and Madagascar. These outbreaks revealed the lack of surveillance and preparedness of Madagascar and other countries. Thus, it was decided in 2007 to establish a syndrome-based surveillance network to monitor dengue-like illness. OBJECTIVE: This study aims to evaluate the use of capillary blood samples blotted on filter papers for molecular diagnosis of CHIKV infection. Venous blood samples can be difficult to obtain and the shipment of serum in appropriate temperature conditions is too costly for most developing countries. METHODOLOGY AND PRINCIPAL FINDINGS: Venous blood and dried-blood blotted on filter paper (DBFP) were collected during the last CHIKV outbreak in Madagascar (2010) and as part of our routine surveillance of dengue-like illness. All samples were tested by real-time RT-PCR and results with serum and DBFP samples were compared for each patient. The sensitivity and specificity of tests performed with DBFP, relative to those with venous samples (defined as 100%) were 93.1% (95% CI:[84.7–97.7]) and 94.4% (95% CI:[88.3–97.7]), respectively. The Kappa coefficient 0.87 (95% CI:[0.80–0.94]) was excellent. CONCLUSION: This study shows that DBFP specimens can be used as a cost-effective alternative sampling method for the surveillance and monitoring of CHIKV circulation and emergence in developing countries, and probably also for other arboviruses. The loss of sensitivity is insignificant and involved a very small number of patients, all with low viral loads. Whether viruses can be isolated from dried blood spots remains to be determined.
format Online
Article
Text
id pubmed-3723542
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-37235422013-08-09 Dried-Blood Spots: A Cost-Effective Field Method for the Detection of Chikungunya Virus Circulation in Remote Areas Andriamandimby, Soa Fy Heraud, Jean-Michel Randrianasolo, Laurence Rafisandratantsoa, Jean Théophile Andriamamonjy, Seta Richard, Vincent PLoS Negl Trop Dis Research Article BACKGROUND: In 2005, there were outbreaks of febrile polyarthritis due to Chikungunya virus (CHIKV) in the Comoros Islands. CHIKV then spread to other islands in the Indian Ocean: La Réunion, Mauritius, Seychelles and Madagascar. These outbreaks revealed the lack of surveillance and preparedness of Madagascar and other countries. Thus, it was decided in 2007 to establish a syndrome-based surveillance network to monitor dengue-like illness. OBJECTIVE: This study aims to evaluate the use of capillary blood samples blotted on filter papers for molecular diagnosis of CHIKV infection. Venous blood samples can be difficult to obtain and the shipment of serum in appropriate temperature conditions is too costly for most developing countries. METHODOLOGY AND PRINCIPAL FINDINGS: Venous blood and dried-blood blotted on filter paper (DBFP) were collected during the last CHIKV outbreak in Madagascar (2010) and as part of our routine surveillance of dengue-like illness. All samples were tested by real-time RT-PCR and results with serum and DBFP samples were compared for each patient. The sensitivity and specificity of tests performed with DBFP, relative to those with venous samples (defined as 100%) were 93.1% (95% CI:[84.7–97.7]) and 94.4% (95% CI:[88.3–97.7]), respectively. The Kappa coefficient 0.87 (95% CI:[0.80–0.94]) was excellent. CONCLUSION: This study shows that DBFP specimens can be used as a cost-effective alternative sampling method for the surveillance and monitoring of CHIKV circulation and emergence in developing countries, and probably also for other arboviruses. The loss of sensitivity is insignificant and involved a very small number of patients, all with low viral loads. Whether viruses can be isolated from dried blood spots remains to be determined. Public Library of Science 2013-07-25 /pmc/articles/PMC3723542/ /pubmed/23936570 http://dx.doi.org/10.1371/journal.pntd.0002339 Text en © 2013 Andriamandimby et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Andriamandimby, Soa Fy
Heraud, Jean-Michel
Randrianasolo, Laurence
Rafisandratantsoa, Jean Théophile
Andriamamonjy, Seta
Richard, Vincent
Dried-Blood Spots: A Cost-Effective Field Method for the Detection of Chikungunya Virus Circulation in Remote Areas
title Dried-Blood Spots: A Cost-Effective Field Method for the Detection of Chikungunya Virus Circulation in Remote Areas
title_full Dried-Blood Spots: A Cost-Effective Field Method for the Detection of Chikungunya Virus Circulation in Remote Areas
title_fullStr Dried-Blood Spots: A Cost-Effective Field Method for the Detection of Chikungunya Virus Circulation in Remote Areas
title_full_unstemmed Dried-Blood Spots: A Cost-Effective Field Method for the Detection of Chikungunya Virus Circulation in Remote Areas
title_short Dried-Blood Spots: A Cost-Effective Field Method for the Detection of Chikungunya Virus Circulation in Remote Areas
title_sort dried-blood spots: a cost-effective field method for the detection of chikungunya virus circulation in remote areas
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3723542/
https://www.ncbi.nlm.nih.gov/pubmed/23936570
http://dx.doi.org/10.1371/journal.pntd.0002339
work_keys_str_mv AT andriamandimbysoafy driedbloodspotsacosteffectivefieldmethodforthedetectionofchikungunyaviruscirculationinremoteareas
AT heraudjeanmichel driedbloodspotsacosteffectivefieldmethodforthedetectionofchikungunyaviruscirculationinremoteareas
AT randrianasololaurence driedbloodspotsacosteffectivefieldmethodforthedetectionofchikungunyaviruscirculationinremoteareas
AT rafisandratantsoajeantheophile driedbloodspotsacosteffectivefieldmethodforthedetectionofchikungunyaviruscirculationinremoteareas
AT andriamamonjyseta driedbloodspotsacosteffectivefieldmethodforthedetectionofchikungunyaviruscirculationinremoteareas
AT richardvincent driedbloodspotsacosteffectivefieldmethodforthedetectionofchikungunyaviruscirculationinremoteareas