Cargando…

Feasibility of Newly Developed Endoscopic Ultrasound with Zone Sonography Technology for Diagnosis of Pancreatic Diseases

BACKGROUND/AIMS: To confirm the feasibility of using newly developed endoscopic ultrasound (EUS) with Zone sonography™ technology (ZST; Fujifilm Corp.). METHODS: Seventy-five patients with pancreatic disorders were enrolled: 45 with intraductal papillary mucinous neoplasm; 15 with ductal carcinoma;...

Descripción completa

Detalles Bibliográficos
Autores principales: Hirooka, Yoshiki, Itoh, Akihiro, Kawashima, Hiroki, Ohno, Eizaburo, Itoh, Yuya, Nakamura, Yosuke, Hiramatsu, Takeshi, Sugimoto, Hiroyuki, Sumi, Hajime, Hayashi, Daijiro, Ohmiya, Naoki, Miyahara, Ryoji, Nakamura, Masanao, Funasaka, Kohei, Ishigami, Masatoshi, Katano, Yoshiaki, Goto, Hidemi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Gastroenterology; the Korean Society of Gastrointestinal Endoscopy; the Korean Association for the Study of the Liver; the Korean Society of Neurogastroenterology and Motility; Korean Association for the Study of Intestinal Diseases; Korean College of Helicobacter and Upper Gastrointestinal Research; Korean Pancreatobiliary Association; Korean Society of Gastrointestinal Cancer 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3724040/
https://www.ncbi.nlm.nih.gov/pubmed/23898392
http://dx.doi.org/10.5009/gnl.2013.7.4.486
Descripción
Sumario:BACKGROUND/AIMS: To confirm the feasibility of using newly developed endoscopic ultrasound (EUS) with Zone sonography™ technology (ZST; Fujifilm Corp.). METHODS: Seventy-five patients with pancreatic disorders were enrolled: 45 with intraductal papillary mucinous neoplasm; 15 with ductal carcinoma; five with neuroendocrine tumors; three with serous cystic neoplasms; and seven with simple cysts. The endoscopes used were EG-530UR2 and EG-530UT2 (Fujifilm Corp.). Two items were evaluated: visualization depth among four frequencies and image quality after automatic adjustment of sound speed (AASS), assessed using a 5-scale Likert scale by two endosonographers blinded to disease status. Because sound speed could be manually controlled, besides AASS, image quality at sound speeds of 1,440 and 1,600 m/sec were also assessed. RESULTS: In all cases, sufficient images were obtained in the range of 3 cm from the EUS probe. Judgments of image quality before AASS were 3.49±0.50, 3.65±0.48, respectively. After AASS, A and B scored 4.36±0.48 and 4.40±0.49 (p<0.0001). There were significant differences in the data before and after AASS and plus 60 m/sec, but no significant difference between the datasets were seen after AASS and at sound speeds manually set for minus 100 m/sec. CONCLUSIONS: EUS with ZST was shown to be feasible in this preliminary experiment. Further evaluation of this novel technology is necessary and awaited.