A Comparison of Two Commercial Volumetry Software Programs in the Analysis of Pulmonary Ground-Glass Nodules: Segmentation Capability and Measurement Accuracy
OBJECTIVE: To compare the segmentation capability of the 2 currently available commercial volumetry software programs with specific segmentation algorithms for pulmonary ground-glass nodules (GGNs) and to assess their measurement accuracy. MATERIALS AND METHODS: In this study, 55 patients with 66 GG...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3725365/ https://www.ncbi.nlm.nih.gov/pubmed/23901328 http://dx.doi.org/10.3348/kjr.2013.14.4.683 |
_version_ | 1782476783964127232 |
---|---|
author | Kim, Hyungjin Park, Chang Min Lee, Sang Min Lee, Hyun-Ju Goo, Jin Mo |
author_facet | Kim, Hyungjin Park, Chang Min Lee, Sang Min Lee, Hyun-Ju Goo, Jin Mo |
author_sort | Kim, Hyungjin |
collection | PubMed |
description | OBJECTIVE: To compare the segmentation capability of the 2 currently available commercial volumetry software programs with specific segmentation algorithms for pulmonary ground-glass nodules (GGNs) and to assess their measurement accuracy. MATERIALS AND METHODS: In this study, 55 patients with 66 GGNs underwent unenhanced low-dose CT. GGN segmentation was performed by using 2 volumetry software programs (LungCARE, Siemens Healthcare; LungVCAR, GE Healthcare). Successful nodule segmentation was assessed visually and morphologic features of GGNs were evaluated to determine factors affecting segmentation by both types of software. In addition, the measurement accuracy of the software programs was investigated by using an anthropomorphic chest phantom containing simulated GGNs. RESULTS: The successful nodule segmentation rate was significantly higher in LungCARE (90.9%) than in LungVCAR (72.7%) (p = 0.012). Vascular attachment was a negatively influencing morphologic feature of nodule segmentation for both software programs. As for measurement accuracy, mean relative volume measurement errors in nodules ≥ 10 mm were 14.89% with LungCARE and 19.96% with LungVCAR. The mean relative attenuation measurement errors in nodules ≥ 10 mm were 3.03% with LungCARE and 5.12% with LungVCAR. CONCLUSION: LungCARE shows significantly higher segmentation success rates than LungVCAR. Measurement accuracy of volume and attenuation of GGNs is acceptable in GGNs ≥ 10 mm by both software programs. |
format | Online Article Text |
id | pubmed-3725365 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-37253652013-07-30 A Comparison of Two Commercial Volumetry Software Programs in the Analysis of Pulmonary Ground-Glass Nodules: Segmentation Capability and Measurement Accuracy Kim, Hyungjin Park, Chang Min Lee, Sang Min Lee, Hyun-Ju Goo, Jin Mo Korean J Radiol Thoracic Imaging OBJECTIVE: To compare the segmentation capability of the 2 currently available commercial volumetry software programs with specific segmentation algorithms for pulmonary ground-glass nodules (GGNs) and to assess their measurement accuracy. MATERIALS AND METHODS: In this study, 55 patients with 66 GGNs underwent unenhanced low-dose CT. GGN segmentation was performed by using 2 volumetry software programs (LungCARE, Siemens Healthcare; LungVCAR, GE Healthcare). Successful nodule segmentation was assessed visually and morphologic features of GGNs were evaluated to determine factors affecting segmentation by both types of software. In addition, the measurement accuracy of the software programs was investigated by using an anthropomorphic chest phantom containing simulated GGNs. RESULTS: The successful nodule segmentation rate was significantly higher in LungCARE (90.9%) than in LungVCAR (72.7%) (p = 0.012). Vascular attachment was a negatively influencing morphologic feature of nodule segmentation for both software programs. As for measurement accuracy, mean relative volume measurement errors in nodules ≥ 10 mm were 14.89% with LungCARE and 19.96% with LungVCAR. The mean relative attenuation measurement errors in nodules ≥ 10 mm were 3.03% with LungCARE and 5.12% with LungVCAR. CONCLUSION: LungCARE shows significantly higher segmentation success rates than LungVCAR. Measurement accuracy of volume and attenuation of GGNs is acceptable in GGNs ≥ 10 mm by both software programs. The Korean Society of Radiology 2013 2013-07-17 /pmc/articles/PMC3725365/ /pubmed/23901328 http://dx.doi.org/10.3348/kjr.2013.14.4.683 Text en Copyright © 2013 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Thoracic Imaging Kim, Hyungjin Park, Chang Min Lee, Sang Min Lee, Hyun-Ju Goo, Jin Mo A Comparison of Two Commercial Volumetry Software Programs in the Analysis of Pulmonary Ground-Glass Nodules: Segmentation Capability and Measurement Accuracy |
title | A Comparison of Two Commercial Volumetry Software Programs in the Analysis of Pulmonary Ground-Glass Nodules: Segmentation Capability and Measurement Accuracy |
title_full | A Comparison of Two Commercial Volumetry Software Programs in the Analysis of Pulmonary Ground-Glass Nodules: Segmentation Capability and Measurement Accuracy |
title_fullStr | A Comparison of Two Commercial Volumetry Software Programs in the Analysis of Pulmonary Ground-Glass Nodules: Segmentation Capability and Measurement Accuracy |
title_full_unstemmed | A Comparison of Two Commercial Volumetry Software Programs in the Analysis of Pulmonary Ground-Glass Nodules: Segmentation Capability and Measurement Accuracy |
title_short | A Comparison of Two Commercial Volumetry Software Programs in the Analysis of Pulmonary Ground-Glass Nodules: Segmentation Capability and Measurement Accuracy |
title_sort | comparison of two commercial volumetry software programs in the analysis of pulmonary ground-glass nodules: segmentation capability and measurement accuracy |
topic | Thoracic Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3725365/ https://www.ncbi.nlm.nih.gov/pubmed/23901328 http://dx.doi.org/10.3348/kjr.2013.14.4.683 |
work_keys_str_mv | AT kimhyungjin acomparisonoftwocommercialvolumetrysoftwareprogramsintheanalysisofpulmonarygroundglassnodulessegmentationcapabilityandmeasurementaccuracy AT parkchangmin acomparisonoftwocommercialvolumetrysoftwareprogramsintheanalysisofpulmonarygroundglassnodulessegmentationcapabilityandmeasurementaccuracy AT leesangmin acomparisonoftwocommercialvolumetrysoftwareprogramsintheanalysisofpulmonarygroundglassnodulessegmentationcapabilityandmeasurementaccuracy AT leehyunju acomparisonoftwocommercialvolumetrysoftwareprogramsintheanalysisofpulmonarygroundglassnodulessegmentationcapabilityandmeasurementaccuracy AT goojinmo acomparisonoftwocommercialvolumetrysoftwareprogramsintheanalysisofpulmonarygroundglassnodulessegmentationcapabilityandmeasurementaccuracy AT kimhyungjin comparisonoftwocommercialvolumetrysoftwareprogramsintheanalysisofpulmonarygroundglassnodulessegmentationcapabilityandmeasurementaccuracy AT parkchangmin comparisonoftwocommercialvolumetrysoftwareprogramsintheanalysisofpulmonarygroundglassnodulessegmentationcapabilityandmeasurementaccuracy AT leesangmin comparisonoftwocommercialvolumetrysoftwareprogramsintheanalysisofpulmonarygroundglassnodulessegmentationcapabilityandmeasurementaccuracy AT leehyunju comparisonoftwocommercialvolumetrysoftwareprogramsintheanalysisofpulmonarygroundglassnodulessegmentationcapabilityandmeasurementaccuracy AT goojinmo comparisonoftwocommercialvolumetrysoftwareprogramsintheanalysisofpulmonarygroundglassnodulessegmentationcapabilityandmeasurementaccuracy |