Cargando…

The Diagnostic Accuracy of Radionuclide Arthrography for Prosthetic Loosening in Hip and Knee Arthroplasty

Purpose of Study. Diagnosis of prosthetic loosening in hip and knee arthroplasty remains a challenge. Although there are a number of diagnostic tools, no single test or combination is 100% sensitive or specific. There has been a recent interest in the use of radionuclide arthrography (RNA) for detec...

Descripción completa

Detalles Bibliográficos
Autores principales: French, Timothy H., Russell, Nicholas, Pillai, Anand
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3725762/
https://www.ncbi.nlm.nih.gov/pubmed/23936835
http://dx.doi.org/10.1155/2013/693436
_version_ 1782278581114634240
author French, Timothy H.
Russell, Nicholas
Pillai, Anand
author_facet French, Timothy H.
Russell, Nicholas
Pillai, Anand
author_sort French, Timothy H.
collection PubMed
description Purpose of Study. Diagnosis of prosthetic loosening in hip and knee arthroplasty remains a challenge. Although there are a number of diagnostic tools, no single test or combination is 100% sensitive or specific. There has been a recent interest in the use of radionuclide arthrography (RNA) for detection of prosthetic loosening. Methods. A retrospective review of 45 consecutive RNA scans from 2005 to 2010 was conducted. RNA findings were compared with intraoperative findings at revision and/or serial radiographic examinations to confirm loosening. A component was considered loose if sequential radiographs demonstrated macromotion, gross subsidence, or progressive radiolucency. Results. There were 26 females and 17 males, with mean age at RNA of 71 years (range of 53–89 years) and mean time from index surgery, 6.4 years (range of 0.5–23 years). There were 23 total knee replacements (TKR) (19 primary and 4 revision) and 20 total hip replacements (THR) (11 primary and 9 revision). 15 patients underwent revision surgery following RNA. Strict inclusion criteria allowed 27 patients for further analysis. Sixteen RNA scans were suggestive of loosening, of which 14 were confirmed loose. Eleven scans were suggestive of a stable prosthesis, of which 10 were confirmed well fixed. RNA had a sensitivity of 93%, specificity of 83%, positive predictive value of 88%, and negative predictive value of 91%. Conclusion. Radionuclide arthrography should be considered a useful adjunct in the diagnosis of prosthetic loosening in the challenging patient.
format Online
Article
Text
id pubmed-3725762
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-37257622013-08-09 The Diagnostic Accuracy of Radionuclide Arthrography for Prosthetic Loosening in Hip and Knee Arthroplasty French, Timothy H. Russell, Nicholas Pillai, Anand Biomed Res Int Clinical Study Purpose of Study. Diagnosis of prosthetic loosening in hip and knee arthroplasty remains a challenge. Although there are a number of diagnostic tools, no single test or combination is 100% sensitive or specific. There has been a recent interest in the use of radionuclide arthrography (RNA) for detection of prosthetic loosening. Methods. A retrospective review of 45 consecutive RNA scans from 2005 to 2010 was conducted. RNA findings were compared with intraoperative findings at revision and/or serial radiographic examinations to confirm loosening. A component was considered loose if sequential radiographs demonstrated macromotion, gross subsidence, or progressive radiolucency. Results. There were 26 females and 17 males, with mean age at RNA of 71 years (range of 53–89 years) and mean time from index surgery, 6.4 years (range of 0.5–23 years). There were 23 total knee replacements (TKR) (19 primary and 4 revision) and 20 total hip replacements (THR) (11 primary and 9 revision). 15 patients underwent revision surgery following RNA. Strict inclusion criteria allowed 27 patients for further analysis. Sixteen RNA scans were suggestive of loosening, of which 14 were confirmed loose. Eleven scans were suggestive of a stable prosthesis, of which 10 were confirmed well fixed. RNA had a sensitivity of 93%, specificity of 83%, positive predictive value of 88%, and negative predictive value of 91%. Conclusion. Radionuclide arthrography should be considered a useful adjunct in the diagnosis of prosthetic loosening in the challenging patient. Hindawi Publishing Corporation 2013 2013-07-15 /pmc/articles/PMC3725762/ /pubmed/23936835 http://dx.doi.org/10.1155/2013/693436 Text en Copyright © 2013 Timothy H. French et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
French, Timothy H.
Russell, Nicholas
Pillai, Anand
The Diagnostic Accuracy of Radionuclide Arthrography for Prosthetic Loosening in Hip and Knee Arthroplasty
title The Diagnostic Accuracy of Radionuclide Arthrography for Prosthetic Loosening in Hip and Knee Arthroplasty
title_full The Diagnostic Accuracy of Radionuclide Arthrography for Prosthetic Loosening in Hip and Knee Arthroplasty
title_fullStr The Diagnostic Accuracy of Radionuclide Arthrography for Prosthetic Loosening in Hip and Knee Arthroplasty
title_full_unstemmed The Diagnostic Accuracy of Radionuclide Arthrography for Prosthetic Loosening in Hip and Knee Arthroplasty
title_short The Diagnostic Accuracy of Radionuclide Arthrography for Prosthetic Loosening in Hip and Knee Arthroplasty
title_sort diagnostic accuracy of radionuclide arthrography for prosthetic loosening in hip and knee arthroplasty
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3725762/
https://www.ncbi.nlm.nih.gov/pubmed/23936835
http://dx.doi.org/10.1155/2013/693436
work_keys_str_mv AT frenchtimothyh thediagnosticaccuracyofradionuclidearthrographyforprostheticlooseninginhipandkneearthroplasty
AT russellnicholas thediagnosticaccuracyofradionuclidearthrographyforprostheticlooseninginhipandkneearthroplasty
AT pillaianand thediagnosticaccuracyofradionuclidearthrographyforprostheticlooseninginhipandkneearthroplasty
AT frenchtimothyh diagnosticaccuracyofradionuclidearthrographyforprostheticlooseninginhipandkneearthroplasty
AT russellnicholas diagnosticaccuracyofradionuclidearthrographyforprostheticlooseninginhipandkneearthroplasty
AT pillaianand diagnosticaccuracyofradionuclidearthrographyforprostheticlooseninginhipandkneearthroplasty