Cargando…
Biomechanical comparison of anterior lumbar interbody fusion: stand-alone interbody cage versus interbody cage with pedicle screw fixation - a finite element analysis
BACKGROUND: Anterior lumbar interbody fusion (ALIF) followed by pedicle screw fixation (PSF) is used to restore the height of the intervertebral disc and provide stability. Recently, stand-alone interbody cage with anterior fixation has been introduced, which eliminates the need for posterior surger...
Autores principales: | Choi, Kyung-Chul, Ryu, Kyeong-Sik, Lee, Sang-Ho, Kim, Yeong Hyeon, Lee, Sung Jae, Park, Chun-Kun |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3726285/ https://www.ncbi.nlm.nih.gov/pubmed/23890389 http://dx.doi.org/10.1186/1471-2474-14-220 |
Ejemplares similares
-
Biomechanical effects of polyaxial pedicle screw fixation on the lumbosacral segments with an anterior interbody cage support
por: Chen, Shih-Hao, et al.
Publicado: (2007) -
Impact of cage position on biomechanical performance of stand-alone lateral lumbar interbody fusion: a finite element analysis
por: Nan, Chong, et al.
Publicado: (2022) -
Comparing expandable and static interbody cages in lumbar interbody fusion
por: Elgafy, Hossein, et al.
Publicado: (2023) -
Biomechanical comparison of a new stand-alone anterior lumbar interbody fusion cage with established fixation techniques – a three-dimensional finite element analysis
por: Chen, Shih-Hao, et al.
Publicado: (2008) -
Biomechanical Comparison of Multilevel Stand-Alone Lumbar Lateral Interbody Fusion With Posterior Pedicle Screws: An In Vitro Study
por: Mok, James M., et al.
Publicado: (2023)