The complementary benefit of anterior segment optical coherence tomography in penetrating keratoplasty

PURPOSE: To evaluate the utility of anterior segment optical coherence tomography (AS-OCT) assessment in the pre- and postsurgical management of full-thickness corneal grafts. METHODS: Seventy eyes of 58 patients who had penetrating keratoplasty were included in the study. High resolution AS-OCT sca...

Descripción completa

Detalles Bibliográficos
Autores principales: Yenerel, Nursal Melda, Kucumen, Raciha Beril, Gorgun, Ebru
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3726587/
https://www.ncbi.nlm.nih.gov/pubmed/23901261
http://dx.doi.org/10.2147/OPTH.S45904
_version_ 1782278666987765760
author Yenerel, Nursal Melda
Kucumen, Raciha Beril
Gorgun, Ebru
author_facet Yenerel, Nursal Melda
Kucumen, Raciha Beril
Gorgun, Ebru
author_sort Yenerel, Nursal Melda
collection PubMed
description PURPOSE: To evaluate the utility of anterior segment optical coherence tomography (AS-OCT) assessment in the pre- and postsurgical management of full-thickness corneal grafts. METHODS: Seventy eyes of 58 patients who had penetrating keratoplasty were included in the study. High resolution AS-OCT scans of the cornea and the anterior segment were performed before and after transplantation in 17 eyes with the Visante™ optical coherence tomography. Fifty-three eyes were examined in the late postoperative period. RESULTS: The mean follow-up was 4.3 years (range, 1–15 years). Six different graft–host junctions were identified. Three patients with graft rejection, four patients with anterior synechia, and three patients with corneal ulcer were evaluated. Preoperative evaluation of eyes with semiopaque and totally opaque corneas revealed important information about anterior segment structures additional to slit-lamp findings. CONCLUSION: AS-OCT is a useful complementary tool for the evaluation of penetrating corneal transplantation surgery and in the management of its postoperative complications.
format Online
Article
Text
id pubmed-3726587
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-37265872013-07-30 The complementary benefit of anterior segment optical coherence tomography in penetrating keratoplasty Yenerel, Nursal Melda Kucumen, Raciha Beril Gorgun, Ebru Clin Ophthalmol Original Research PURPOSE: To evaluate the utility of anterior segment optical coherence tomography (AS-OCT) assessment in the pre- and postsurgical management of full-thickness corneal grafts. METHODS: Seventy eyes of 58 patients who had penetrating keratoplasty were included in the study. High resolution AS-OCT scans of the cornea and the anterior segment were performed before and after transplantation in 17 eyes with the Visante™ optical coherence tomography. Fifty-three eyes were examined in the late postoperative period. RESULTS: The mean follow-up was 4.3 years (range, 1–15 years). Six different graft–host junctions were identified. Three patients with graft rejection, four patients with anterior synechia, and three patients with corneal ulcer were evaluated. Preoperative evaluation of eyes with semiopaque and totally opaque corneas revealed important information about anterior segment structures additional to slit-lamp findings. CONCLUSION: AS-OCT is a useful complementary tool for the evaluation of penetrating corneal transplantation surgery and in the management of its postoperative complications. Dove Medical Press 2013 2013-07-23 /pmc/articles/PMC3726587/ /pubmed/23901261 http://dx.doi.org/10.2147/OPTH.S45904 Text en © 2013 Yenerel et al, publisher and licensee Dove Medical Press Ltd This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited.
spellingShingle Original Research
Yenerel, Nursal Melda
Kucumen, Raciha Beril
Gorgun, Ebru
The complementary benefit of anterior segment optical coherence tomography in penetrating keratoplasty
title The complementary benefit of anterior segment optical coherence tomography in penetrating keratoplasty
title_full The complementary benefit of anterior segment optical coherence tomography in penetrating keratoplasty
title_fullStr The complementary benefit of anterior segment optical coherence tomography in penetrating keratoplasty
title_full_unstemmed The complementary benefit of anterior segment optical coherence tomography in penetrating keratoplasty
title_short The complementary benefit of anterior segment optical coherence tomography in penetrating keratoplasty
title_sort complementary benefit of anterior segment optical coherence tomography in penetrating keratoplasty
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3726587/
https://www.ncbi.nlm.nih.gov/pubmed/23901261
http://dx.doi.org/10.2147/OPTH.S45904
work_keys_str_mv AT yenerelnursalmelda thecomplementarybenefitofanteriorsegmentopticalcoherencetomographyinpenetratingkeratoplasty
AT kucumenracihaberil thecomplementarybenefitofanteriorsegmentopticalcoherencetomographyinpenetratingkeratoplasty
AT gorgunebru thecomplementarybenefitofanteriorsegmentopticalcoherencetomographyinpenetratingkeratoplasty
AT yenerelnursalmelda complementarybenefitofanteriorsegmentopticalcoherencetomographyinpenetratingkeratoplasty
AT kucumenracihaberil complementarybenefitofanteriorsegmentopticalcoherencetomographyinpenetratingkeratoplasty
AT gorgunebru complementarybenefitofanteriorsegmentopticalcoherencetomographyinpenetratingkeratoplasty