Cargando…

Plasma L-Ergothioneine Measurement by High-Performance Liquid Chromatography and Capillary Electrophoresis after a Pre-Column Derivatization with 5-Iodoacetamidofluorescein (5-IAF) and Fluorescence Detection

Two sensitive and reproducible capillary electrophoresis and high-performance liquid chromatography-fluorescence procedures were established for quantitative determination of L-egothioneine in plasma. After derivatization of L-ergothioneine with 5-iodoacetamidofluorescein, the separation was carried...

Descripción completa

Detalles Bibliográficos
Autores principales: Sotgia, Salvatore, Pisanu, Elisabetta, Pintus, Gianfranco, Erre, Gian Luca, Pinna, Gerard Aime, Deiana, Luca, Carru, Ciriaco, Zinellu, Angelo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3726632/
https://www.ncbi.nlm.nih.gov/pubmed/23922985
http://dx.doi.org/10.1371/journal.pone.0070374
_version_ 1782278677409562624
author Sotgia, Salvatore
Pisanu, Elisabetta
Pintus, Gianfranco
Erre, Gian Luca
Pinna, Gerard Aime
Deiana, Luca
Carru, Ciriaco
Zinellu, Angelo
author_facet Sotgia, Salvatore
Pisanu, Elisabetta
Pintus, Gianfranco
Erre, Gian Luca
Pinna, Gerard Aime
Deiana, Luca
Carru, Ciriaco
Zinellu, Angelo
author_sort Sotgia, Salvatore
collection PubMed
description Two sensitive and reproducible capillary electrophoresis and high-performance liquid chromatography-fluorescence procedures were established for quantitative determination of L-egothioneine in plasma. After derivatization of L-ergothioneine with 5-iodoacetamidofluorescein, the separation was carried out by HPLC on an ODS-2 C-18 sperisorb column by using a linear gradient elution and by HPCE on an uncoated fused silica capillary, 50 µm id, and 60 cm length. The methods were validated and found to be linear in the range of 0.3 to 10 µmol/l. The limit of quantification was 0.27 µmol/l for HPCE and 0.15 µmol/l for HPLC. The variations for intra- and inter-assay precision were around 6 RSD%, and the mean recovery accuracy close to 100% (96.11%).
format Online
Article
Text
id pubmed-3726632
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-37266322013-08-06 Plasma L-Ergothioneine Measurement by High-Performance Liquid Chromatography and Capillary Electrophoresis after a Pre-Column Derivatization with 5-Iodoacetamidofluorescein (5-IAF) and Fluorescence Detection Sotgia, Salvatore Pisanu, Elisabetta Pintus, Gianfranco Erre, Gian Luca Pinna, Gerard Aime Deiana, Luca Carru, Ciriaco Zinellu, Angelo PLoS One Research Article Two sensitive and reproducible capillary electrophoresis and high-performance liquid chromatography-fluorescence procedures were established for quantitative determination of L-egothioneine in plasma. After derivatization of L-ergothioneine with 5-iodoacetamidofluorescein, the separation was carried out by HPLC on an ODS-2 C-18 sperisorb column by using a linear gradient elution and by HPCE on an uncoated fused silica capillary, 50 µm id, and 60 cm length. The methods were validated and found to be linear in the range of 0.3 to 10 µmol/l. The limit of quantification was 0.27 µmol/l for HPCE and 0.15 µmol/l for HPLC. The variations for intra- and inter-assay precision were around 6 RSD%, and the mean recovery accuracy close to 100% (96.11%). Public Library of Science 2013-07-29 /pmc/articles/PMC3726632/ /pubmed/23922985 http://dx.doi.org/10.1371/journal.pone.0070374 Text en © 2013 Sotgia et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Sotgia, Salvatore
Pisanu, Elisabetta
Pintus, Gianfranco
Erre, Gian Luca
Pinna, Gerard Aime
Deiana, Luca
Carru, Ciriaco
Zinellu, Angelo
Plasma L-Ergothioneine Measurement by High-Performance Liquid Chromatography and Capillary Electrophoresis after a Pre-Column Derivatization with 5-Iodoacetamidofluorescein (5-IAF) and Fluorescence Detection
title Plasma L-Ergothioneine Measurement by High-Performance Liquid Chromatography and Capillary Electrophoresis after a Pre-Column Derivatization with 5-Iodoacetamidofluorescein (5-IAF) and Fluorescence Detection
title_full Plasma L-Ergothioneine Measurement by High-Performance Liquid Chromatography and Capillary Electrophoresis after a Pre-Column Derivatization with 5-Iodoacetamidofluorescein (5-IAF) and Fluorescence Detection
title_fullStr Plasma L-Ergothioneine Measurement by High-Performance Liquid Chromatography and Capillary Electrophoresis after a Pre-Column Derivatization with 5-Iodoacetamidofluorescein (5-IAF) and Fluorescence Detection
title_full_unstemmed Plasma L-Ergothioneine Measurement by High-Performance Liquid Chromatography and Capillary Electrophoresis after a Pre-Column Derivatization with 5-Iodoacetamidofluorescein (5-IAF) and Fluorescence Detection
title_short Plasma L-Ergothioneine Measurement by High-Performance Liquid Chromatography and Capillary Electrophoresis after a Pre-Column Derivatization with 5-Iodoacetamidofluorescein (5-IAF) and Fluorescence Detection
title_sort plasma l-ergothioneine measurement by high-performance liquid chromatography and capillary electrophoresis after a pre-column derivatization with 5-iodoacetamidofluorescein (5-iaf) and fluorescence detection
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3726632/
https://www.ncbi.nlm.nih.gov/pubmed/23922985
http://dx.doi.org/10.1371/journal.pone.0070374
work_keys_str_mv AT sotgiasalvatore plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection
AT pisanuelisabetta plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection
AT pintusgianfranco plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection
AT erregianluca plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection
AT pinnagerardaime plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection
AT deianaluca plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection
AT carruciriaco plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection
AT zinelluangelo plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection