Cargando…
Plasma L-Ergothioneine Measurement by High-Performance Liquid Chromatography and Capillary Electrophoresis after a Pre-Column Derivatization with 5-Iodoacetamidofluorescein (5-IAF) and Fluorescence Detection
Two sensitive and reproducible capillary electrophoresis and high-performance liquid chromatography-fluorescence procedures were established for quantitative determination of L-egothioneine in plasma. After derivatization of L-ergothioneine with 5-iodoacetamidofluorescein, the separation was carried...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3726632/ https://www.ncbi.nlm.nih.gov/pubmed/23922985 http://dx.doi.org/10.1371/journal.pone.0070374 |
_version_ | 1782278677409562624 |
---|---|
author | Sotgia, Salvatore Pisanu, Elisabetta Pintus, Gianfranco Erre, Gian Luca Pinna, Gerard Aime Deiana, Luca Carru, Ciriaco Zinellu, Angelo |
author_facet | Sotgia, Salvatore Pisanu, Elisabetta Pintus, Gianfranco Erre, Gian Luca Pinna, Gerard Aime Deiana, Luca Carru, Ciriaco Zinellu, Angelo |
author_sort | Sotgia, Salvatore |
collection | PubMed |
description | Two sensitive and reproducible capillary electrophoresis and high-performance liquid chromatography-fluorescence procedures were established for quantitative determination of L-egothioneine in plasma. After derivatization of L-ergothioneine with 5-iodoacetamidofluorescein, the separation was carried out by HPLC on an ODS-2 C-18 sperisorb column by using a linear gradient elution and by HPCE on an uncoated fused silica capillary, 50 µm id, and 60 cm length. The methods were validated and found to be linear in the range of 0.3 to 10 µmol/l. The limit of quantification was 0.27 µmol/l for HPCE and 0.15 µmol/l for HPLC. The variations for intra- and inter-assay precision were around 6 RSD%, and the mean recovery accuracy close to 100% (96.11%). |
format | Online Article Text |
id | pubmed-3726632 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-37266322013-08-06 Plasma L-Ergothioneine Measurement by High-Performance Liquid Chromatography and Capillary Electrophoresis after a Pre-Column Derivatization with 5-Iodoacetamidofluorescein (5-IAF) and Fluorescence Detection Sotgia, Salvatore Pisanu, Elisabetta Pintus, Gianfranco Erre, Gian Luca Pinna, Gerard Aime Deiana, Luca Carru, Ciriaco Zinellu, Angelo PLoS One Research Article Two sensitive and reproducible capillary electrophoresis and high-performance liquid chromatography-fluorescence procedures were established for quantitative determination of L-egothioneine in plasma. After derivatization of L-ergothioneine with 5-iodoacetamidofluorescein, the separation was carried out by HPLC on an ODS-2 C-18 sperisorb column by using a linear gradient elution and by HPCE on an uncoated fused silica capillary, 50 µm id, and 60 cm length. The methods were validated and found to be linear in the range of 0.3 to 10 µmol/l. The limit of quantification was 0.27 µmol/l for HPCE and 0.15 µmol/l for HPLC. The variations for intra- and inter-assay precision were around 6 RSD%, and the mean recovery accuracy close to 100% (96.11%). Public Library of Science 2013-07-29 /pmc/articles/PMC3726632/ /pubmed/23922985 http://dx.doi.org/10.1371/journal.pone.0070374 Text en © 2013 Sotgia et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Sotgia, Salvatore Pisanu, Elisabetta Pintus, Gianfranco Erre, Gian Luca Pinna, Gerard Aime Deiana, Luca Carru, Ciriaco Zinellu, Angelo Plasma L-Ergothioneine Measurement by High-Performance Liquid Chromatography and Capillary Electrophoresis after a Pre-Column Derivatization with 5-Iodoacetamidofluorescein (5-IAF) and Fluorescence Detection |
title | Plasma L-Ergothioneine Measurement by High-Performance Liquid Chromatography and Capillary Electrophoresis after a Pre-Column Derivatization with 5-Iodoacetamidofluorescein (5-IAF) and Fluorescence Detection |
title_full | Plasma L-Ergothioneine Measurement by High-Performance Liquid Chromatography and Capillary Electrophoresis after a Pre-Column Derivatization with 5-Iodoacetamidofluorescein (5-IAF) and Fluorescence Detection |
title_fullStr | Plasma L-Ergothioneine Measurement by High-Performance Liquid Chromatography and Capillary Electrophoresis after a Pre-Column Derivatization with 5-Iodoacetamidofluorescein (5-IAF) and Fluorescence Detection |
title_full_unstemmed | Plasma L-Ergothioneine Measurement by High-Performance Liquid Chromatography and Capillary Electrophoresis after a Pre-Column Derivatization with 5-Iodoacetamidofluorescein (5-IAF) and Fluorescence Detection |
title_short | Plasma L-Ergothioneine Measurement by High-Performance Liquid Chromatography and Capillary Electrophoresis after a Pre-Column Derivatization with 5-Iodoacetamidofluorescein (5-IAF) and Fluorescence Detection |
title_sort | plasma l-ergothioneine measurement by high-performance liquid chromatography and capillary electrophoresis after a pre-column derivatization with 5-iodoacetamidofluorescein (5-iaf) and fluorescence detection |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3726632/ https://www.ncbi.nlm.nih.gov/pubmed/23922985 http://dx.doi.org/10.1371/journal.pone.0070374 |
work_keys_str_mv | AT sotgiasalvatore plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection AT pisanuelisabetta plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection AT pintusgianfranco plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection AT erregianluca plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection AT pinnagerardaime plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection AT deianaluca plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection AT carruciriaco plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection AT zinelluangelo plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection |