Cargando…

External dose-rate conversion factors of radionuclides for air submersion, ground surface contamination and water immersion based on the new ICRP dosimetric setting

For the assessment of external doses due to contaminated environment, the dose-rate conversion factors (DCFs) prescribed in Federal Guidance Report 12 (FGR 12) and FGR 13 have been widely used. Recently, there were significant changes in dosimetric models and parameters, which include the use of the...

Descripción completa

Detalles Bibliográficos
Autores principales: Yoo, Song Jae, Jang, Han-Ki, Lee, Jai-Ki, Noh, Siwan, Cho, Gyuseong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3729024/
https://www.ncbi.nlm.nih.gov/pubmed/23542764
http://dx.doi.org/10.1093/rpd/nct045
_version_ 1782278946178465792
author Yoo, Song Jae
Jang, Han-Ki
Lee, Jai-Ki
Noh, Siwan
Cho, Gyuseong
author_facet Yoo, Song Jae
Jang, Han-Ki
Lee, Jai-Ki
Noh, Siwan
Cho, Gyuseong
author_sort Yoo, Song Jae
collection PubMed
description For the assessment of external doses due to contaminated environment, the dose-rate conversion factors (DCFs) prescribed in Federal Guidance Report 12 (FGR 12) and FGR 13 have been widely used. Recently, there were significant changes in dosimetric models and parameters, which include the use of the Reference Male and Female Phantoms and the revised tissue weighting factors, as well as the updated decay data of radionuclides. In this study, the DCFs for effective and equivalent doses were calculated for three exposure settings: skyshine, groundshine and water immersion. Doses to the Reference Phantoms were calculated by Monte Carlo simulations with the MCNPX 2.7.0 radiation transport code for 26 mono-energy photons between 0.01 and 10 MeV. The transport calculations were performed for the source volume within the cut-off distances practically contributing to the dose rates, which were determined by a simplified calculation model. For small tissues for which the reduction of variances are difficult, the equivalent dose ratios to a larger tissue (with lower statistical errors) nearby were employed to make the calculation efficient. Empirical response functions relating photon energies, and the organ equivalent doses or the effective doses were then derived by the use of cubic-spline fitting of the resulting doses for 26 energy points. The DCFs for all radionuclides considered important were evaluated by combining the photon emission data of the radionuclide and the empirical response functions. Finally, contributions of accompanied beta particles to the skin equivalent doses and the effective doses were calculated separately and added to the DCFs. For radionuclides considered in this study, the new DCFs for the three exposure settings were within ±10 % when compared with DCFs in FGR 13.
format Online
Article
Text
id pubmed-3729024
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-37290242013-07-31 External dose-rate conversion factors of radionuclides for air submersion, ground surface contamination and water immersion based on the new ICRP dosimetric setting Yoo, Song Jae Jang, Han-Ki Lee, Jai-Ki Noh, Siwan Cho, Gyuseong Radiat Prot Dosimetry Papers For the assessment of external doses due to contaminated environment, the dose-rate conversion factors (DCFs) prescribed in Federal Guidance Report 12 (FGR 12) and FGR 13 have been widely used. Recently, there were significant changes in dosimetric models and parameters, which include the use of the Reference Male and Female Phantoms and the revised tissue weighting factors, as well as the updated decay data of radionuclides. In this study, the DCFs for effective and equivalent doses were calculated for three exposure settings: skyshine, groundshine and water immersion. Doses to the Reference Phantoms were calculated by Monte Carlo simulations with the MCNPX 2.7.0 radiation transport code for 26 mono-energy photons between 0.01 and 10 MeV. The transport calculations were performed for the source volume within the cut-off distances practically contributing to the dose rates, which were determined by a simplified calculation model. For small tissues for which the reduction of variances are difficult, the equivalent dose ratios to a larger tissue (with lower statistical errors) nearby were employed to make the calculation efficient. Empirical response functions relating photon energies, and the organ equivalent doses or the effective doses were then derived by the use of cubic-spline fitting of the resulting doses for 26 energy points. The DCFs for all radionuclides considered important were evaluated by combining the photon emission data of the radionuclide and the empirical response functions. Finally, contributions of accompanied beta particles to the skin equivalent doses and the effective doses were calculated separately and added to the DCFs. For radionuclides considered in this study, the new DCFs for the three exposure settings were within ±10 % when compared with DCFs in FGR 13. Oxford University Press 2013-08 2013-03-29 /pmc/articles/PMC3729024/ /pubmed/23542764 http://dx.doi.org/10.1093/rpd/nct045 Text en © The Author 2013. Published by Oxford University Press. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by-nc/3.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com.
spellingShingle Papers
Yoo, Song Jae
Jang, Han-Ki
Lee, Jai-Ki
Noh, Siwan
Cho, Gyuseong
External dose-rate conversion factors of radionuclides for air submersion, ground surface contamination and water immersion based on the new ICRP dosimetric setting
title External dose-rate conversion factors of radionuclides for air submersion, ground surface contamination and water immersion based on the new ICRP dosimetric setting
title_full External dose-rate conversion factors of radionuclides for air submersion, ground surface contamination and water immersion based on the new ICRP dosimetric setting
title_fullStr External dose-rate conversion factors of radionuclides for air submersion, ground surface contamination and water immersion based on the new ICRP dosimetric setting
title_full_unstemmed External dose-rate conversion factors of radionuclides for air submersion, ground surface contamination and water immersion based on the new ICRP dosimetric setting
title_short External dose-rate conversion factors of radionuclides for air submersion, ground surface contamination and water immersion based on the new ICRP dosimetric setting
title_sort external dose-rate conversion factors of radionuclides for air submersion, ground surface contamination and water immersion based on the new icrp dosimetric setting
topic Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3729024/
https://www.ncbi.nlm.nih.gov/pubmed/23542764
http://dx.doi.org/10.1093/rpd/nct045
work_keys_str_mv AT yoosongjae externaldoserateconversionfactorsofradionuclidesforairsubmersiongroundsurfacecontaminationandwaterimmersionbasedonthenewicrpdosimetricsetting
AT janghanki externaldoserateconversionfactorsofradionuclidesforairsubmersiongroundsurfacecontaminationandwaterimmersionbasedonthenewicrpdosimetricsetting
AT leejaiki externaldoserateconversionfactorsofradionuclidesforairsubmersiongroundsurfacecontaminationandwaterimmersionbasedonthenewicrpdosimetricsetting
AT nohsiwan externaldoserateconversionfactorsofradionuclidesforairsubmersiongroundsurfacecontaminationandwaterimmersionbasedonthenewicrpdosimetricsetting
AT chogyuseong externaldoserateconversionfactorsofradionuclidesforairsubmersiongroundsurfacecontaminationandwaterimmersionbasedonthenewicrpdosimetricsetting