Cargando…

In situ X-ray beam imaging using an off-axis magnifying coded aperture camera system

An imaging model and an image reconstruction algorithm for a transparent X-ray beam imaging and position measuring instrument are presented. The instrument relies on a coded aperture camera to record magnified images of the footprint of the incident beam on a thin foil placed in the beam at an obliq...

Descripción completa

Detalles Bibliográficos
Autores principales: Kachatkou, Anton, Kyele, Nicholas, Scott, Peter, van Silfhout, Roelof
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Union of Crystallography 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3729246/
https://www.ncbi.nlm.nih.gov/pubmed/23765302
http://dx.doi.org/10.1107/S0909049513011060
_version_ 1782278952120745984
author Kachatkou, Anton
Kyele, Nicholas
Scott, Peter
van Silfhout, Roelof
author_facet Kachatkou, Anton
Kyele, Nicholas
Scott, Peter
van Silfhout, Roelof
author_sort Kachatkou, Anton
collection PubMed
description An imaging model and an image reconstruction algorithm for a transparent X-ray beam imaging and position measuring instrument are presented. The instrument relies on a coded aperture camera to record magnified images of the footprint of the incident beam on a thin foil placed in the beam at an oblique angle. The imaging model represents the instrument as a linear system whose impulse response takes into account the image blur owing to the finite thickness of the foil, the shape and size of camera’s aperture and detector’s point-spread function. The image reconstruction algorithm first removes the image blur using the modelled impulse response function and then corrects for geometrical distortions caused by the foil tilt. The performance of the image reconstruction algorithm was tested in experiments at synchrotron radiation beamlines. The results show that the proposed imaging system produces images of the X-ray beam cross section with a quality comparable with images obtained using X-ray cameras that are exposed to the direct beam.
format Online
Article
Text
id pubmed-3729246
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher International Union of Crystallography
record_format MEDLINE/PubMed
spelling pubmed-37292462013-08-02 In situ X-ray beam imaging using an off-axis magnifying coded aperture camera system Kachatkou, Anton Kyele, Nicholas Scott, Peter van Silfhout, Roelof J Synchrotron Radiat Research Papers An imaging model and an image reconstruction algorithm for a transparent X-ray beam imaging and position measuring instrument are presented. The instrument relies on a coded aperture camera to record magnified images of the footprint of the incident beam on a thin foil placed in the beam at an oblique angle. The imaging model represents the instrument as a linear system whose impulse response takes into account the image blur owing to the finite thickness of the foil, the shape and size of camera’s aperture and detector’s point-spread function. The image reconstruction algorithm first removes the image blur using the modelled impulse response function and then corrects for geometrical distortions caused by the foil tilt. The performance of the image reconstruction algorithm was tested in experiments at synchrotron radiation beamlines. The results show that the proposed imaging system produces images of the X-ray beam cross section with a quality comparable with images obtained using X-ray cameras that are exposed to the direct beam. International Union of Crystallography 2013-07-01 2013-05-18 /pmc/articles/PMC3729246/ /pubmed/23765302 http://dx.doi.org/10.1107/S0909049513011060 Text en © Anton Kachatkou et al. 2013 http://creativecommons.org/licenses/by/2.0/uk/ This is an open-access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.
spellingShingle Research Papers
Kachatkou, Anton
Kyele, Nicholas
Scott, Peter
van Silfhout, Roelof
In situ X-ray beam imaging using an off-axis magnifying coded aperture camera system
title In situ X-ray beam imaging using an off-axis magnifying coded aperture camera system
title_full In situ X-ray beam imaging using an off-axis magnifying coded aperture camera system
title_fullStr In situ X-ray beam imaging using an off-axis magnifying coded aperture camera system
title_full_unstemmed In situ X-ray beam imaging using an off-axis magnifying coded aperture camera system
title_short In situ X-ray beam imaging using an off-axis magnifying coded aperture camera system
title_sort in situ x-ray beam imaging using an off-axis magnifying coded aperture camera system
topic Research Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3729246/
https://www.ncbi.nlm.nih.gov/pubmed/23765302
http://dx.doi.org/10.1107/S0909049513011060
work_keys_str_mv AT kachatkouanton insituxraybeamimagingusinganoffaxismagnifyingcodedaperturecamerasystem
AT kyelenicholas insituxraybeamimagingusinganoffaxismagnifyingcodedaperturecamerasystem
AT scottpeter insituxraybeamimagingusinganoffaxismagnifyingcodedaperturecamerasystem
AT vansilfhoutroelof insituxraybeamimagingusinganoffaxismagnifyingcodedaperturecamerasystem