Cargando…
In situ X-ray beam imaging using an off-axis magnifying coded aperture camera system
An imaging model and an image reconstruction algorithm for a transparent X-ray beam imaging and position measuring instrument are presented. The instrument relies on a coded aperture camera to record magnified images of the footprint of the incident beam on a thin foil placed in the beam at an obliq...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Union of Crystallography
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3729246/ https://www.ncbi.nlm.nih.gov/pubmed/23765302 http://dx.doi.org/10.1107/S0909049513011060 |
_version_ | 1782278952120745984 |
---|---|
author | Kachatkou, Anton Kyele, Nicholas Scott, Peter van Silfhout, Roelof |
author_facet | Kachatkou, Anton Kyele, Nicholas Scott, Peter van Silfhout, Roelof |
author_sort | Kachatkou, Anton |
collection | PubMed |
description | An imaging model and an image reconstruction algorithm for a transparent X-ray beam imaging and position measuring instrument are presented. The instrument relies on a coded aperture camera to record magnified images of the footprint of the incident beam on a thin foil placed in the beam at an oblique angle. The imaging model represents the instrument as a linear system whose impulse response takes into account the image blur owing to the finite thickness of the foil, the shape and size of camera’s aperture and detector’s point-spread function. The image reconstruction algorithm first removes the image blur using the modelled impulse response function and then corrects for geometrical distortions caused by the foil tilt. The performance of the image reconstruction algorithm was tested in experiments at synchrotron radiation beamlines. The results show that the proposed imaging system produces images of the X-ray beam cross section with a quality comparable with images obtained using X-ray cameras that are exposed to the direct beam. |
format | Online Article Text |
id | pubmed-3729246 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | International Union of Crystallography |
record_format | MEDLINE/PubMed |
spelling | pubmed-37292462013-08-02 In situ X-ray beam imaging using an off-axis magnifying coded aperture camera system Kachatkou, Anton Kyele, Nicholas Scott, Peter van Silfhout, Roelof J Synchrotron Radiat Research Papers An imaging model and an image reconstruction algorithm for a transparent X-ray beam imaging and position measuring instrument are presented. The instrument relies on a coded aperture camera to record magnified images of the footprint of the incident beam on a thin foil placed in the beam at an oblique angle. The imaging model represents the instrument as a linear system whose impulse response takes into account the image blur owing to the finite thickness of the foil, the shape and size of camera’s aperture and detector’s point-spread function. The image reconstruction algorithm first removes the image blur using the modelled impulse response function and then corrects for geometrical distortions caused by the foil tilt. The performance of the image reconstruction algorithm was tested in experiments at synchrotron radiation beamlines. The results show that the proposed imaging system produces images of the X-ray beam cross section with a quality comparable with images obtained using X-ray cameras that are exposed to the direct beam. International Union of Crystallography 2013-07-01 2013-05-18 /pmc/articles/PMC3729246/ /pubmed/23765302 http://dx.doi.org/10.1107/S0909049513011060 Text en © Anton Kachatkou et al. 2013 http://creativecommons.org/licenses/by/2.0/uk/ This is an open-access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited. |
spellingShingle | Research Papers Kachatkou, Anton Kyele, Nicholas Scott, Peter van Silfhout, Roelof In situ X-ray beam imaging using an off-axis magnifying coded aperture camera system |
title |
In situ X-ray beam imaging using an off-axis magnifying coded aperture camera system |
title_full |
In situ X-ray beam imaging using an off-axis magnifying coded aperture camera system |
title_fullStr |
In situ X-ray beam imaging using an off-axis magnifying coded aperture camera system |
title_full_unstemmed |
In situ X-ray beam imaging using an off-axis magnifying coded aperture camera system |
title_short |
In situ X-ray beam imaging using an off-axis magnifying coded aperture camera system |
title_sort | in situ x-ray beam imaging using an off-axis magnifying coded aperture camera system |
topic | Research Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3729246/ https://www.ncbi.nlm.nih.gov/pubmed/23765302 http://dx.doi.org/10.1107/S0909049513011060 |
work_keys_str_mv | AT kachatkouanton insituxraybeamimagingusinganoffaxismagnifyingcodedaperturecamerasystem AT kyelenicholas insituxraybeamimagingusinganoffaxismagnifyingcodedaperturecamerasystem AT scottpeter insituxraybeamimagingusinganoffaxismagnifyingcodedaperturecamerasystem AT vansilfhoutroelof insituxraybeamimagingusinganoffaxismagnifyingcodedaperturecamerasystem |